J Instrum ; 9(5)2014 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-24883078

RESUMO

Over the last two decades there have been a growing number of designs for positron emission tomography (PET) cameras optimized to image the breast. These devices, commonly known as positron emission mammography (PEM) cameras allow much more spatial resolution by putting the photon detectors directly on the breast. PEM cameras have a compact geometry with a restricted field of view (FOV) thus exhibiting higher performance and lower cost than large whole body PET scanners. Typical PEM designs are based on scintillators such as bismuth germanate (BGO), lutetium oxorthosilicate (LSO) or lutetium yttrium orthosicilate (LYSO), and characterized by large parallax error due to deficiency of the depth of interaction (DOI) information from crystals. In the case of parallel geometry PEM, large parallax error results in poor image resolution along the vertical axis. In the framework of the Voxel Imaging PET (VIP) pathfinder project, we propose a high resolution PEM scanner based on pixelated solid-state CdTe detectors. The pixel PEM device with a millimeter-size pixel pitch provides an excellent spatial resolution in all directions 8 times better than standard commercial devices with a point spread function (PSF) of 1 mm full width at half maximum (FWHM) and excellent energy resolution of down to 1.6% FWHM at 511 keV photons at room temperature. The system is capable to detect down to 1 mm diameter hot spheres in warm background.

2.
J Instrum ; 82013 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-23814604

RESUMO

The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For PET scanners, conventional algorithms like Filtered Back-Projection (FBP) and Ordered Subset Expectation Maximization (OSEM) are straightforward to use and give good results. However, FBP presents difficulties for detectors with limited angular coverage like PEM and Compton gamma cameras, whereas OSEM has an impractically large time and memory consumption for a Compton gamma camera with a large number of channels. In this article, the Origin Ensemble (OE) algorithm is evaluated as an alternative algorithm for image reconstruction. Monte Carlo simulations of the PET design are used to compare the performance of OE, FBP and OSEM in terms of the bias, variance and average mean squared error (MSE) image quality metrics. For the PEM and Compton camera designs, results obtained with OE are presented.

3.
J Instrum ; 82013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23750177

RESUMO

We report on the characterization of 2 mm thick CdTe diode detector with Schottky contacts to be employed in a novel conceptual design of PET scanner. Results at -8°C with an applied bias voltage of -1000 V/mm show a 1.2% FWHM energy resolution at 511 keV. Coincidence time resolution has been measured by triggering on the preamplifier output signal to improve the timing resolution of the detector. Results at the same bias and temperature conditions show a FWHM of 6 ns with a minimum acceptance energy of 500 keV. These results show that pixelated CdTe Schottky diode is an excellent candidate for the development of next generation nuclear medical imaging devices such as PET, Compton gamma cameras, and especially PET-MRI hybrid systems when used in a magnetic field immune configuration.

4.
J Instrum ; 82013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23750176

RESUMO

A positron emission mammograph (PEM) is an organ dedicated positron emission tomography (PET) scanner for breast cancer detection. State-of-the-art PEMs employing scintillating crystals as detection medium can provide metabolic images of the breast with significantly higher sensitivity and specificity with respect to standard whole body PET scanners. Over the past few years, crystal PEMs have dramatically increased their importance in the diagnosis and treatment of early stage breast cancer. Nevertheless, designs based on scintillators are characterized by an intrinsic deficiency of the depth of interaction (DOI) information from relatively thick crystals constraining the size of the smallest detectable tumor. This work shows how to overcome such intrinsic limitation by substituting scintillating crystals with pixelated CdTe detectors. The proposed novel design is developed within the Voxel Imaging PET (VIP) Pathfinder project and evaluated via Monte Carlo simulation. The volumetric spatial resolution of the VIP-PEM is expected to be up to 6 times better than standard commercial devices with a point spread function of 1 mm full width at half maximum (FWHM) in all directions. Pixelated CdTe detectors can also provide an energy resolution as low as 1.5% FWHM at 511 keV for a virtually pure signal with negligible contribution from scattered events.