1.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38533653

RESUMO

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Assuntos
Insuficiência da Valva Aórtica , Valvuloplastia com Balão , Modelos Animais de Doenças , Hemodinâmica , Animais , Hemodinâmica/efeitos dos fármacos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Sus scrofa , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Desenho de Equipamento , Recuperação de Função Fisiológica , Doença Aguda , Cateteres Cardíacos , Fatores de Tempo , Índice de Gravidade de Doença , Função Ventricular Esquerda/efeitos dos fármacos
2.
Magn Reson Med ; 92(1): 346-360, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38394163

RESUMO

PURPOSE: To introduce alternating current-controlled, conductive ink-printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin-echo sequences. METHODS: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR-compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR-compatible current supply circuit was designed, and the performance of the current-controlled markers was tested in one postmortem animal experiment using the current supply circuit. RESULTS: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom-designed, 20-gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit. CONCLUSION: Current-controlled conductive ink-printed markers can be placed on custom or commercial MR-compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Animais , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Artefatos , Imagem por Ressonância Magnética Intervencionista/instrumentação
3.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1741-1754, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354176

RESUMO

BACKGROUND: Intramyocardial guidewire navigation is a novel technique that allows free transcatheter movement within ventricular muscle. Guidewire radial depth, between endocardial and epicardial surfaces, is ambiguous by x-ray and echocardiography. OBJECTIVES: The aim of this study was to develop a simple tool, EDEN (Electrocardiographic Radial Depth Navigation), to indicate radial depth during intramyocardial guidewire navigation. Combined with routine imaging, EDEN facilitates a new family of intramyocardial catheter procedures to slice, reshape, pace, and ablate the heart. METHODS: We mapped intramyocardial electrograms of left and right ventricular walls and septum during open- and closed-chest swine procedures (N = 53), including MIRTH (Myocardial Intramural Remodeling by Transvenous Tether) ventriculoplasty. We identified radial depth-dependent features on unipolar electrograms. We developed a machine learning-based classifier to indicate categorical position, and modeled the findings in silico to test understanding of the physiology. RESULTS: EDEN signatures distinguished 5 depth zones throughout left and right ventricular free walls and interventricular septum. Relative ST-segment elevation magnitude best discriminated position and was maximum (40.1 ± 6.5 mV) in the midmyocardium. Subendocardial positions exhibited dominant Q waves with lower-amplitude ST segments (16.8 ± 5.8 mV), whereas subepicardial positions exhibited dominant R waves with lower-amplitude ST segments (15.7 ± 4.8 mV). EDEN was unaffected by pacing-induced left bundle branch block. ST-segment elevation declined over minutes and reappeared after submillimeter guidewire manipulation. Modeling recapitulated EDEN features. The machine learning-based classifier was 97% accurate. EDEN successfully guided MIRTH ventriculoplasty. CONCLUSIONS: EDEN provides a simple and reproducible real-time reflection of categorical guidewire-tip radial depth during intramyocardial guidewire navigation. Used in tandem with x-ray, EDEN enables novel, transcatheter, intramyocardial therapies such as MIRTH, SESAME (Septal Surfing Along Midline Endocardium), and cerclage ventriculoplasty.


Assuntos
Eletrocardiografia , Miocárdio , Animais , Suínos , Eletrocardiografia/métodos , Coração , Endocárdio , Ventrículos do Coração/diagnóstico por imagem
4.
Magn Reson Med ; 89(2): 845-858, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36198118

RESUMO

PURPOSE: We describe a clinical grade, "active", monopole antenna-based metallic guidewire that has a continuous shaft-to-tip image profile, a pre-shaped tip-curve, standard 0.89 mm (0.035″) outer diameter, and a detachable connector for catheter exchange during cardiovascular catheterization at 0.55T. METHODS: Electromagnetic simulations were performed to characterize the magnetic field around the antenna whip for continuous tip visibility. The active guidewire was manufactured using medical grade materials in an ISO Class 7 cleanroom. RF-induced heating of the active guidewire prototype was tested in one gel phantom per ASTM 2182-19a, alone and in tandem with clinical metal-braided catheters. Real-time MRI visibility was tested in one gel phantom and in-vivo in two swine. Mechanical performance was compared with commercial equivalents. RESULTS: The active guidewire provided continuous "profile" shaft and tip visibility in-vitro and in-vivo, analogous to guidewire shaft-and-tip profiles under X-ray. The MRI signal signature matched simulation results. Maximum unscaled RF-induced temperature rise was 5.2°C and 6.5°C (3.47 W/kg local background specific absorption rate), alone and in tandem with a steel-braided catheter, respectively. Mechanical characteristics matched commercial comparator guidewires. CONCLUSION: The active guidewire was clearly visible via real-time MRI at 0.55T and exhibits a favorable geometric sensitivity profile depicting the guidewire continuously from shaft-to-tip including a unique curved-tip signature. RF-induced heating is clinically acceptable. This design allows safe device navigation through luminal structures and heart chambers. The detachable connector allows delivery and exchange of cardiovascular catheters while maintaining guidewire position. This enhanced guidewire design affords the expected performance of X-ray guidewires during human MRI catheterization.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Suínos , Humanos , Animais , Cateterismo Cardíaco/métodos , Desenho de Equipamento , Cateteres Cardíacos , Imagens de Fantasmas
5.
Magn Reson Med ; 86(3): 1786-1801, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33860962

RESUMO

PURPOSE: This work aims to fabricate RF antenna components on metallic needle surfaces using biocompatible polyester tubing and conductive ink to develop an active interventional MRI needle for clinical use at 0.55 Tesla. METHODS: A custom computer numeric control-based conductive ink printing method was developed. Based on electromagnetic simulation results, thin-film RF antennas were printed with conductive ink and used to fabricate a medical grade, 20-gauge (0.87 mm outer diameter), 90-mm long active interventional MRI needle. The MRI visibility performance of the active needle prototype was tested in vitro in 1 gel phantom and in vivo in 1 swine. A nearly identical active needle constructed using a 44 American Wire Gauge insulated copper wire-wound RF receiver antenna was a comparator. The RF-induced heating risk was evaluated in a gel phantom per American Society for Testing and Materials (ASTM) 2182-19. RESULTS: The active needle prototype with printed RF antenna was clearly visible both in vitro and in vivo under MRI. The maximum RF-induced temperature rise of prototypes with printed RF antenna and insulated copper wire antenna after a 3.96 W/kg, 15 min. long scan were 1.64°C and 8.21°C, respectively. The increase in needle diameter was 98 µm and 264 µm for prototypes with printed RF antenna and copper wire-wound antenna, respectively. CONCLUSION: The active needle prototype with conductive ink printed antenna provides distinct device visibility under MRI. Variations on the needle surface are mitigated compared to use of a 44 American Wire Gauge copper wire. RF-induced heating tests support device RF safety under MRI. The proposed method enables fabrication of small diameter active interventional MRI devices having complex geometries, something previously difficult using conventional methods.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Animais , Condutividade Elétrica , Desenho de Equipamento , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Suínos , Temperatura
6.
Biomed Opt Express ; 10(1): 242-251, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30775097

RESUMO

Biopsy needles with embedded force sensors can eliminate the needle deflection and the needle targeting failure risks during MRI guided biopsy procedures. Fabry-Pérot interferometry (FPI) based sensors are small, compact and immune to electromagnetic and RF interferences, and therefore they are suitable for needle guidance under MRI. In this work, an FPI based fiber optic force sensor design and its integration to an 18-gauge MRI compatible biopsy needle are presented. The custom designed FPI sensor provides a force measurement range up to 13 N with a resolution of 0.1 N through benchtop experiments. The MRI compatibility of the sensor was evaluated using a commercially available prostate phantom under MRI.