Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38279942

RESUMO

OBJECTIVES: To evaluate the safety of current guidelines on methotrexate (MTX) administration in women with pregnancy of unknown location (PUL) who are considered to have a high risk of underlying ectopic pregnancy (EP), and to investigate whether implementation of these guidelines would result in inadvertent exposure to MTX of viable intrauterine pregnancies (IUP). METHODS: This was a retrospective observational study of consecutive clinically stable women who were classified with PUL at the early pregnancy unit of Nepean Hospital, Sydney, Australia, between 2007 and 2021. PUL was defined as a positive pregnancy test in the absence of signs of IUP or EP on transvaginal ultrasound. Patients with a PUL that behaved biochemically like an EP, but for which the location of pregnancy was not confirmed on ultrasound, were eligible for MTX to minimize the risk of subsequent tubal rupture. Criteria discussed in the guidelines of the American College of Obstetricians and Gynecologists (ACOG), American Society for Reproductive Medicine (ASRM), Royal College of Obstetricians and Gynaecologists (RCOG) and National Institute for Health and Care Excellence (NICE) were applied to the PUL database. The number of patients eligible to receive MTX and the number with an underlying viable IUP who would be inadvertently prescribed MTX were calculated. RESULTS: A total of 816 women with PUL were reviewed, of whom 724 had complete data and were included in the final analysis. Six patients had persistent PUL and the remaining 718 had a diagnosis of viable IUP, non-viable IUP, EP or failed PUL. According to the ACOG, ASRM, RCOG and NICE guidelines, the rate of MTX administration among patients with PUL would have been 2.76%, 4.56%, 0.41% and 35.36%, respectively. However, no persistent PUL would have received MTX according to the ACOG, ASRM and RCOG protocols (the NICE protocol identified patients with persistent PUL with a sensitivity of 100%), and the majority of MTX treatments were unnecessary because those patients were later classified as having non-viable IUP or failed PUL. Application of ACOG and ASRM guidance could result theoretically in inadvertent MTX administration to women with an underlying viable IUP at a rate of 4.1/1000 (3/724). CONCLUSIONS: Current guidelines used to predict high risk of EP in the PUL population lead to inadvertent MTX administration to women with an underlying viable IUP. These guidelines should be used wisely to ensure that no wanted pregnancy is exposed to MTX. Women with PUL should be monitored carefully, and MTX should be used judiciously when the location of pregnancy is yet to be confirmed. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

2.
Ultrasound Obstet Gynecol ; 60(3): 404-413, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35561121

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy of transvaginal ultrasound (TVS) in predicting deep endometriosis (DE) following the International Deep Endometriosis Analysis (IDEA) consensus methodology. METHODS: This was an international multicenter prospective diagnostic accuracy study involving eight centers across six countries (August 2018-November 2019). Consecutive participants with endometriosis suspected based on clinical symptoms or historical diagnosis of endometriosis were included. The index test was TVS performed preoperatively in accordance with the IDEA consensus statement. At each center, the index test was interpreted by a single sonologist. Reference standards were: (1) direct visualization of endometriosis at laparoscopy, as determined by a non-blinded surgeon with expertise in endometriosis surgery; and (2) histological assessment of biopsied/excised tissue. Surgery was performed within 12 months following the index TVS. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios (LR+ and LR-) of TVS in the diagnosis of DE were calculated. RESULTS: Included in the study were 273 participants with complete clinical, TVS, laparoscopic and histological data. Of these, based on histology, 256 (93.8%) were confirmed to have endometriosis, including superficial endometriosis, and 190 (69.6%) were confirmed to have DE. Based on surgical visualization, 207/273 (75.8%) patients had DE. For DE overall, the diagnostic performance of TVS based on surgical visualization as the reference standard was as follows: accuracy, 86.1%; sensitivity, 88.4%; specificity, 78.8%; PPV, 92.9%; NPV, 68.4%; LR+, 4.17; LR-, 0.15, and the diagnostic performance of TVS based on histology as the reference standard was as follows: accuracy, 85.9%; sensitivity, 89.8%; specificity, 75.9%; PPV, 90.4%; NPV, 74.6%; LR+, 3.72; LR-, 0.13. CONCLUSIONS: Using the IDEA consensus methodology provides strong diagnostic accuracy for TVS assessment of DE. We found a higher TVS detection rate of DE overall than that reported by the most recent meta-analysis on the topic (sensitivity, 79%), albeit with a lower specificity. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Endometriose , Endometriose/diagnóstico por imagem , Endometriose/patologia , Endometriose/cirurgia , Feminino , Humanos , Projetos Piloto , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia/métodos , Vagina/diagnóstico por imagem , Vagina/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...