Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Toxins (Basel) ; 14(9)2022 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-36136573

RESUMO

With increasing interest in home dialysis, there is a need for a translational uremic large animal model to evaluate technical innovations in peritoneal dialysis (PD). To this end, we developed a porcine model with kidney failure. Stable chronic kidney injury was induced by bilateral subtotal renal artery embolization. Before applying PD, temporary aggravation of uremia was induced by administration of gentamicin (10 mg/kg i.v. twice daily for 7 days), to obtain uremic solute levels within the range of those of dialysis patients. Peritoneal transport was assessed using a standard peritoneal permeability assessment (SPA). After embolization, urea and creatinine concentrations transiently increased from 1.6 ± 0.3 to 7.5 ± 1.2 mM and from 103 ± 14 to 338 ± 67 µM, respectively, followed by stabilization within 1-2 weeks to 2.5 ± 1.1 mM and 174 ± 28 µM, respectively. Gentamicin induced temporary acute-on-chronic kidney injury with peak urea and creatinine concentrations of 16.7 ± 5.3 mM and 932 ± 470 µM respectively. PD was successfully applied, although frequently complicated by peritonitis. SPA showed a low transport status (D/P creatinine at 4 h of 0.41 (0.36-0.53)) with a mass transfer area coefficient of 9.6 ± 3.1, 4.6 ± 2.6, 3.4 ± 2.3 mL/min for urea, creatinine, and phosphate respectively. In conclusion, this porcine model with on-demand aggravation of uremia is suitable for PD albeit with peritoneal transport characterized by a low transport status.


Assuntos
Diálise Peritoneal , Uremia , Animais , Creatinina , Soluções para Diálise , Gentamicinas , Diálise Peritoneal/efeitos adversos , Fosfatos , Suínos , Ureia , Uremia/terapia
2.
Adv Healthc Mater ; 10(21): e2101103, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34523263

RESUMO

Two of the greatest challenges for successful application of small-diameter in situ tissue-engineered vascular grafts are 1) preventing thrombus formation and 2) harnessing the inflammatory response to the graft to guide functional tissue regeneration. This study evaluates the in vivo performance of electrospun resorbable elastomeric vascular grafts, dual-functionalized with anti-thrombogenic heparin (hep) and anti-inflammatory interleukin 4 (IL-4) using a supramolecular approach. The regenerative capacity of IL-4/hep, hep-only, and bare grafts is investigated as interposition graft in the rat abdominal aorta, with follow-up at key timepoints in the healing cascade (1, 3, 7 days, and 3 months). Routine analyses are augmented with Raman microspectroscopy, in order to acquire the local molecular fingerprints of the resorbing scaffold and developing tissue. Thrombosis is found not to be a confounding factor in any of the groups. Hep-only-functionalized grafts resulted in adverse tissue remodeling, with cases of local intimal hyperplasia. This is negated with the addition of IL-4, which promoted M2 macrophage polarization and more mature neotissue formation. This study shows that with bioactive functionalization, the early inflammatory response can be modulated and affect the composition of neotissue. Nevertheless, variability between graft outcomes is observed within each group, warranting further evaluation in light of clinical translation.


Assuntos
Prótese Vascular , Interleucina-4 , Animais , Heparina , Macrófagos , Ratos , Engenharia Tecidual , Alicerces Teciduais
3.
Biology (Basel) ; 10(6)2021 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-34071069

RESUMO

The preclinical evaluation of novel therapies for chronic kidney disease requires a simple method for the assessment of kidney function in a uremic large animal model. An intravenous bolus of iohexol was administered to goats (13 measurements in n = 3 goats) and pigs (23 measurements in n = 5 pigs) before and after induction of kidney failure, followed by frequent blood sampling up to 1440 min. Plasma clearance (CL) was estimated by a nonlinear mixed-effects model (CLNLME) and by a one-compartmental pharmacokinetic disposition model using iohexol plasma concentrations during the terminal elimination phase (CL1CMT). A simple method (CLSM) for the calculation of plasma clearance was developed based on the most appropriate relationship between CLNLME and CL1CMT. CLSM and CLNLME showed good agreement (CLNLME/CLSM ratio: 1.00 ± 0.07; bias: 0.03 ± 1.64 mL/min; precision CLSM and CLNLME: 80.9% and 80.7%, respectively; the percentage of CLSM estimates falling within ±30% (P30) or ±10% (P10) of CLNLME: 53% and 12%, respectively). For mGFRNLME vs. mGFRSM, bias was -0.25 ± 2.24 and precision was 49.2% and 53.6%, respectively, P30 and P10 for mGFR based on CLSM were 71% and 24%, respectively. A simple method for measurement of GFR in healthy and uremic goats and pigs was successfully developed, which eliminates the need for continuous infusion of an exogenous marker, urine collection and frequent blood sampling.

4.
Lab Anim ; 55(5): 435-442, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34018879

RESUMO

A large craniotomy survival porcine model is useful for scientific research. The surgical approaches and complications of craniotomies in pigs have not been published before. This study describes how large craniotomies were performed in 46 pigs and how the risk of complications was minimized. The major complications were direct postoperative epidural hematomas (n = 3) and sagittal sinus rupture (n = 4). The measures taken to prevent postoperative epidural hematomas consisted of optimizing anesthesia, using bone wax to stop trabecular bleeding, increasing blood pressure before bone flap replacement, tranexamic acid administration, and postoperative recovery of the pigs in the prone position in a dedicated hammock. After these measures, no pig died from a postoperative epidural hematoma. Iatrogenic sagittal sinus rupture occurred in cases where the dura shifted into the craniotome during craniotomy. The dura was detached from the skull through drill holes with custom elevators before craniotomy to minimize the risk of a sagittal sinus rupture. In conclusion, pigs can undergo craniotomy and survive if the right measures are put in place.


Assuntos
Craniotomia , Hematoma Epidural Craniano , Animais , Craniotomia/efeitos adversos , Progressão da Doença , Hematoma Epidural Craniano/cirurgia , Humanos , Período Pós-Operatório , Suínos
5.
Biology (Basel) ; 10(4)2021 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-33916709

RESUMO

A large animal model of (end-stage) kidney disease (ESKD) is needed for the preclinical testing of novel renal replacement therapies. This study aimed to create stable uremia via subtotal renal artery embolization in goats and induce a temporary further decline in kidney function by administration of gentamicin. Renal artery embolization was performed in five Dutch white goats by infusing polyvinyl alcohol particles in branches of the renal artery, aiming for the embolization of ~80% of one kidney and complete embolization of the contralateral kidney. Gentamicin was administered to temporarily further increase the plasma concentrations of uremic toxins. After initial acute kidney injury, urea and creatinine plasma concentrations stabilized 1.5 ± 0.7 months post-embolization and remained elevated (12 ± 1.4 vs. 5.6 ± 0.8 mmol/L and 174 ± 45 vs. 65 ± 5.6 µmol/L, resp.) during follow-up (16 ± 6 months). Gentamicin induced temporary acute-on-chronic kidney injury with a variable increase in plasma concentrations of small solutes (urea 29 ± 15 mmol/L, creatinine 841 ± 584 µmol/L, phosphate 2.2 ± 0.3 mmol/L and potassium 5.0 ± 0.6 mmol/L) and protein-bound uremic toxins representative of patients with ESKD. A uremic goat model characterized by stable moderate uremia was established via subtotal renal artery embolization with the induction of temporary severe acute-on-chronic kidney injury by the administration of gentamicin, allowing preclinical in vivo validation of novel renal replacement technologies.

6.
Am J Physiol Renal Physiol ; 315(5): F1385-F1397, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993277

RESUMO

The key to success in developing a wearable dialysis device is a technique to safely and efficiently regenerate and reuse a small volume of dialysate in a closed-loop system. In a hemodialysis model in goats, we explored whether urea removal by electro-oxidation (EO) could be effectively and safely applied in vivo. A miniature dialysis device was built, containing 1 or 2 "EO units," each with 10 graphite electrodes, with a cumulative electrode surface of 585 cm2 per unit. The units also contained poly(styrene-divinylbenzene) sulfonate beads, FeOOH beads, and activated carbon for respective potassium, phosphate, and chlorine removal. Urea, potassium, and phosphate were infused to create "uremic" conditions. Urea removal was dependent on total electrode surface area [removal of 8 mmol/h (SD 1) and 16 mmol/h (SD 2) and clearance of 12 ml/min (SD 1) and 20 ml/min (SD 3) with 1 and 2 EO units, respectively] and plasma urea concentration but not on flow rate. Extrapolating urea removal with 2 EO units to 24 h would suffice to remove daily urea production, but for intermittent dialysis, additional units would be required. EO had practically no effects on potassium and phosphate removal or electrolyte balance. However, slight ammonium releasewas observed, and some chlorine release at higher dialysate flow rates. Minor effects on acid-base balance were observed, possibly partly due to infusion of chloride. Mild hemolysis occurred, which seemed related to urea infusion. In conclusion, clinically relevant urea removal was achieved in vivo by electro-oxidation. Efficacy and safety testing in a large-animal model with uremia is now indicated.


Assuntos
Soluções para Diálise/metabolismo , Diálise Renal/instrumentação , Ureia/sangue , Uremia/terapia , Dispositivos Eletrônicos Vestíveis , Equilíbrio Ácido-Base , Desequilíbrio Ácido-Base/etiologia , Desequilíbrio Ácido-Base/fisiopatologia , Animais , Creatinina/sangue , Modelos Animais de Doenças , Desenho de Equipamento , Cabras , Hemólise , Miniaturização , Modelos Biológicos , Oxirredução , Fosfatos/sangue , Potássio/sangue , Diálise Renal/efeitos adversos , Fatores de Tempo , Uremia/sangue , Uremia/fisiopatologia , Vigília
7.
Nephrol Dial Transplant ; 32(6): 951-959, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27220758

RESUMO

BACKGROUND: Patients on standard intermittent haemodialysis suffer from strong fluctuations in plasma potassium and phosphate. Prolonged dialysis with a wearable device, based on continuous regeneration of a small volume of dialysate using ion exchangers, could moderate these fluctuations and offer increased clearance of these electrolytes. We report in vivo results on the efficacy of potassium and phosphate adsorption from a wearable dialysis device. We explore whether equilibration of ion exchangers at physiological Ca 2+ , Mg 2+ and hypotonic NaCl can prevent calcium/magnesium adsorption and net sodium release, respectively. Effects on pH and HCO3- were studied. METHODS: Healthy goats were instrumented with a central venous catheter and dialysed. Potassium and phosphate were infused to achieve plasma concentrations commonly observed in dialysis patients. An adsorption cartridge containing 80 g sodium poly(styrene-divinylbenzene) sulphonate and 40 g iron oxide hydroxide beads for potassium and phosphate removal, respectively, was incorporated in a dialysate circuit. Sorbents were equilibrated and regenerated with a solution containing NaCl, CaCl 2 and MgCl 2 . Blood was pumped over a dialyser and dialysate was recirculated over the adsorption cartridge in a countercurrent direction. RESULTS: Potassium and phosphate adsorption was 7.7 ± 2.7 and 4.9 ± 1.3 mmol in 3 h, respectively. Adsorption capacity remained constant during consecutive dialysis sessions and increased with increasing K + and PO43-. Equilibration at physiological Ca 2+ and Mg 2+ prevented net adsorption, eliminating the need for post-cartridge calcium and magnesium infusion. Equilibration at hypotonic NaCl prevented net sodium release Fe 2+ and arterial pH did not change. Bicarbonate was adsorbed, which could be prevented by equilibrating at HCO3- 15 mM. CONCLUSION: We demonstrate clinically relevant, concentration-dependent, pH-neutral potassium and phosphate removal in vivo with small volumes of regenerable ion exchangers in our prototype wearable dialysis device. Application of the selected ion exchangers for potassium and phosphate removal in a wearable dialysis device appears to be effective with a low-risk profile.


Assuntos
Fosfatos/isolamento & purificação , Potássio/isolamento & purificação , Diálise Renal/instrumentação , Adsorção , Animais , Bicarbonatos/sangue , Reutilização de Equipamento , Compostos Férricos/química , Cabras , Humanos , Troca Iônica , Magnésio/sangue , Fosfatos/sangue , Potássio/sangue , Melhoria de Qualidade , Diálise Renal/métodos , Sódio/química
8.
PLoS One ; 9(10): e106960, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25310187

RESUMO

Chronic stress or long-term administration of glucocorticoids disrupts the hypothalamus-pituitary-adrenal system leading to continuous high levels of glucocorticoids and insulin resistance (IR). This pre-diabetic state can eventually develop into type 2 diabetes mellitus and has been associated with a higher risk to develop depressive disorders. The mechanisms underlying the link between chronic stress, IR and depression remains unclear. The present study aimed to establish a stress-depression model in mice to further study the effects of stress-induced changes upon insulin sensitivity and behavioural consequences. A pilot study was conducted to establish the optimal administration route and a pragmatic measurement of IR. Subsequently, 6-month-old C57BL/6NCrl mice were exposed to long-term oral corticosterone treatment via the drinking water. To evaluate insulin sensitivity changes, blood glucose and plasma insulin levels were measured at different time-points throughout treatment and mice were behaviourally assessed in the elevated zero maze (EZM), forced swimming test (FST) and open field test to reveal behavioural changes. Long-term corticosterone treatment increased body weight and decreased insulin sensitivity. The latter was revealed by a higher IR index and increased insulin in the plasma, whereas blood glucose levels remained unchanged. Corticosterone treatment induced longer immobility times in the FST, reflecting depressive-like behaviour. No effects were observed upon anxiety as measured in the EZM. The effect of the higher body weight of the CORT treated animals at time of testing did not influence behaviour in the EZM or FST, as no differences were found in general locomotor activity. Long-term corticosterone treatment via the drinking water reduces insulin sensitivity and induces depressive-like behaviour in the C57BL/6 mouse. This mouse model could thus be used to further explore the underlying mechanisms of chronic stress-induced T2DM and its association with increased prevalence of major depressive disorder on the short-term and other behavioural adaptations on the longer term.


Assuntos
Comportamento Animal/efeitos dos fármacos , Corticosterona/farmacologia , Depressão/induzido quimicamente , Resistência à Insulina/fisiologia , Insulina/sangue , Animais , Comportamento Animal/fisiologia , Glicemia , Depressão/sangue , Depressão/fisiopatologia , Modelos Animais de Doenças , Sistema Hipotálamo-Hipofisário/efeitos dos fármacos , Sistema Hipotálamo-Hipofisário/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Atividade Motora/efeitos dos fármacos , Atividade Motora/fisiologia , Projetos Piloto , Sistema Hipófise-Suprarrenal/efeitos dos fármacos , Sistema Hipófise-Suprarrenal/fisiopatologia , Estresse Psicológico/sangue , Estresse Psicológico/fisiopatologia , Natação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...