1.
Biosens Bioelectron ; 196: 113745, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34753078

RESUMO

In this study, we developed a low-cost and easy-to-use capacitive biosensor employing printed-circuit-board (PCB)-based technique for electrode fabrication and a specific alternative current (AC) signal for AC Electrokinetics (ACEK) effect excitation. Fast, accurate, and highly sensitive detection and quantification of bisphenol A (BPA) was achieved. An easy characterization of the biofunctionalization process is introduced by measuring interfacial capacitance which is simple and superior to most of methods currently in use. The frequency and amplitude of the AC signal used for capacitive interrogation were optimized to achieve maximum interfacial capacitance and maximum sensitivity. To evaluate the performance of the developed biosensor, its operation was compared with in-house microfabricated and commercially available electrodes. The limit-of-detection (LOD) obtained using the PCB-based electrodes was found to be at least one order of magnitude lower than that obtained with the commercial and in-house microfabricated electrodes. The linear range for BPA detection was wide from 1 fM to 10 pM with an LOD of 109.5 aM and sample to result in 20s. The biosensor operation was validated by spike-and-recovery tests of BPA using commercial food samples. Thus, the platform has a potential as an on-site detection of bisphenol A in low-resource settings.


Assuntos
Técnicas Biossensoriais , Compostos Benzidrílicos , Eletrodos , Limite de Detecção , Fenóis
2.
Electrophoresis ; 37(5-6): 719-26, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26790840

RESUMO

The ability to control and pump high ionic strength fluids inside microchannels forms a major advantage for clinical diagnostics and drug screening processes, where high conductive biological and physiological buffers are used. Despite the known potential of AC electro-thermal (ACET) effect in different biomedical applications, comparatively little is known about controlling the velocity and direction of fluid inside the chip. Here, we proposed to discretize the conventional electrodes to form various asymmetric electrode structures in order to control the fluid direction by simple switching the appropriate electric potential applied to the discretized electrodes. The ACET pumping effect was numerically studied by solving electrical, thermal and hydrodynamic multi-physic coupled equations to optimize the geometrical dimensions of the discretized system. PBS solutions with different ionic strength were seeded with 1 µm sized fluorescent particles and electrothermally driven fluid motion was observed inside the channel for different electrode structures. Experimental analyses confirm that the proposed micropump is efficient for a conductivity range between 0.1 and 1 S/m and the efficiency improves by increasing the voltage amplitude. Behavior of the proposed electrode-electrolyte system is discussed by lumped circuit model. Frequency response of system illustrated that the optimal frequency range increases by increasing the conductivity of medium. For 0.18 S/m PBS solution, the constant pumping effect was observed at frequency range between 100 kHz and 1 MHz, while frequency range of 100 kHz to 5 MHZ was observed for 0.42 S/m. The characteristics of experimental results were in good agreement with the theoretical model.


Assuntos
Biotecnologia/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Simulação por Computador , Eletrodos , Desenho de Equipamento , Concentração Osmolar