Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pestic Biochem Physiol ; 149: 54-60, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30033016

RESUMO

Insects have developed tolerance against mycoses caused by entomopathogenic fungi through several humoral and cellular mechanisms. Antioxidant enzymes such as superoxide dismutase, lipid peroxidase, and peroxidase can play a role in defense against mycosis, but the physiological interactions between the fungus and the insect are not well characterized. In this study, the effects of infection by entomopathogenic fungus, Aspergillus flavus on the antioxidant defense system of Spodoptera litura, were investigated. The fungi, A. flavus exposure resulted in modification of the levels of antioxidant enzymes, as well as significant decline in phenoloxidase titers and the total hemocyte count 48 h post exposure. A significant increase was observed in detoxifying enzymes. All these results suggest that A. flavus infects S. litura by directly acting on the immune system, resulting in decreased immune function. Bioassay results showed that A. flavus affects third and fourth instar larvae of S. litura. This report supports the importance of A. flavus as a candidate for biological control of S. litura.


Assuntos
Aspergillus flavus/patogenicidade , Larva/fisiologia , Peroxidases/metabolismo , Spodoptera/fisiologia , Superóxido Dismutase/metabolismo , Animais , Bioensaio , Hemócitos/citologia , Sistema Imunitário/imunologia , Larva/enzimologia , Monofenol Mono-Oxigenase/metabolismo , Spodoptera/enzimologia , Spodoptera/crescimento & desenvolvimento , Spodoptera/metabolismo
2.
J Med Phys ; 42(1): 48-54, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28405108

RESUMO

The aim of this article is to assess Tamil Nadu pediatric computed tomography (CT) diagnostic reference levels (DRLs) by collecting radiation dose data for the most commonly performed CT examinations. This work was performed for thirty CT scanners installed in various parts of the Tamil Nadu region. The patient cohort was divided into two age groups: <1 year, and 1-5 years. CT dose indices were measured using a 10 cm3 pencil ion chamber with pediatric head and body polymethyl methacrylate phantoms. Dose data such as volumetric CT dose index (CTDIv) and dose length product (DLP) on a minimum of twenty average-sized pediatric patients in each category were recorded to calculate a mean site CTDIv and DLP value. The rounded 75th percentile was used to calculate a pediatric DRL for each hospital, and then region by compiling all results. Data were collected for 3600 pediatric patients. Pediatric CT DRL for two age groups: <1 year (CTDIv and DLP of head [20 mGy, 352 mGy.cm], chest [7 mGy, 120 mGy.cm] and abdomen [12 mGy, 252 mGy.cm]), and 1-5 years (CTDIv and DLP of head [38 mGy, 505 mGy.cm], chest [8 mGy, 132 mGy.cm] and abdomen [14 mGy, 270 mGy.cm]) for select procedures have been calculated. Proposed pediatric DRLs of CTDIv and DLP for head procedure were lower, and for chest and abdomen procedures were higher than European pediatric DRLs for both age groups.

3.
Carbohydr Polym ; 156: 34-44, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-27842831

RESUMO

Cotton fabric was processed with microwave (Ar) plasma to alter its hydrophilicity. The process parameters namely microwave power, process gas pressure and processing time were optimized using Box-Behnken method available in the Design Expert software. It was observed that certain combinations of process parameters improved existing hydrophilicity while the other combinations decreased it. ATR-FTIR spectral analysis was used to identify the strain induced in inter chain, intra chain, and inter sheet hydrogen bond and glycosidic covalent bond due to plasma treatment. X-ray diffraction (XRD) studies was used to analyze the effect of plasma on unit cell parameters and degree of crystallinity. Fabric surface etching was identified using FESEM analysis. Thus, it can be concluded that the increase/decrease in the hydrophilicity of the plasma treated fabric was due to these structural and physical changes.


Assuntos
Celulose/química , Glicosídeos/química , Gossypium/química , Ligação de Hidrogênio , Micro-Ondas , Gases em Plasma , Argônio , Têxteis
4.
J Med Phys ; 40(3): 170-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26500404

RESUMO

In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA) at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT) dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP). Using these values, the weighted computed tomography dose index (CTDIw) and in turn the volumetric CTDI (CTDIv) were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB), India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.

6.
J Med Phys ; 39(1): 50-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24600173

RESUMO

Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDIw), volumetric CT dose index (CTDIv), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDIw, CTDIv, and DLP were calculated. The DRL is established based on the third quartile value of CTDIv and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...