Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Expert Opin Drug Deliv ; 19(9): 1165-1176, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36053114

RESUMO

OBJECTIVES: Many current subcutaneous (SC) biologic therapies may require >1 mL volume or have increased viscosity, necessitating new delivery system approaches. This study evaluated 2-mL large-volume autoinjector (LVAI) delivery performance across varying solution viscosities and design inputs to assess the design space and identify configurations that produce practical injection times. METHODS: Investigational LVAI delivery duration and volume, depot location, and tissue effects were examined in both air and in vivo models across various pre-filled syringe (PFS) cannula types (27 G Ultra-thin wall [UTW], 27 G special thin wall [STW], or 29 G thin-wall [TW]), drive spring forces (SFLOW or SFHIGH), and Newtonian solutions (2.3-50 centipoise [cP]). RESULTS: Within each design configuration, increasing PFS internal diameters and spring forces reduced delivery times, while increasing viscosity increased times. The 27 G UTW PFS/SFHIGH combination achieved shorter delivery times across all injection conditions, with 2 mL in vivo durations <15 seconds at ≤31 cP and routinely <20 seconds at 39 and 51 cP, with nominal and transitory tissue effects. CONCLUSION: PFS cannula and spring force combinations can be tailored to achieve various injection durations across viscosities, while UTW PFS enables faster rates to potentially better accommodate human factors during LVAI injection, especially at high viscosity.


Assuntos
Seringas , Humanos , Injeções , Injeções Subcutâneas , Viscosidade
2.
NMR Biomed ; 26(6): 709-17, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23378198

RESUMO

We studied the tissue growth dynamics of tissue-engineered cartilage at an early growth stage after cell seeding for four weeks using sodium triple-quantum coherence NMR spectroscopy. The following tissue-engineering constructs were studied: 1) bovine chondrocytes cultured in alginate beads; 2) bovine chondrocytes cultured as pellets (scaffold-free chondrocyte pellets); and 3) human marrow stromal cells (HMSCs) seeded in collagen/chitosan based biomimetic scaffolds. We found that the sodium triple-quantum coherence spectroscopy could differentiate between different tissue-engineered constructs and native tissues based on the fast and slow components of relaxation rate as well as on the average quadrupolar coupling. Both fast (Tf ) and slow (Ts ) relaxation times were found to be longer in chondrocyte pellets and biomimetic scaffolds compared to chondrocytes suspended in alginate beads and human articular cartilage tissues. In all cases, it was found that relaxation rates and motion of sodium ions measured from correlation times were dependent on the amount of macromolecules, high cell density and anisotropy of the cartilage tissue-engineered constructs. Average quadrupolar couplings were found to be lower in the engineered tissue compared to native tissue, presumably due to the lack of order in collagen accumulated in the engineered tissue. These results support the use of sodium triple-quantum coherence spectroscopy as a tool to investigate anisotropy and growth dynamics of cartilage tissue-engineered constructs in a simple and reliable way.


Assuntos
Cartilagem Articular/citologia , Condrócitos/fisiologia , Espectroscopia de Ressonância Magnética/métodos , Engenharia Tecidual , Animais , Biomimética , Bovinos , Proliferação de Células , Células Cultivadas , Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...