Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Sports Med ; : 3635465241232002, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591459

RESUMO

BACKGROUND: Blood flow restriction training (BFR-t) data are heterogeneous. It is unclear whether rehabilitation with BFR-t after an anterior cruciate ligament (ACL) injury is more effective in improving muscle strength and muscle size than standard rehabilitation. PURPOSE: To review outcomes after an ACL injury and subsequent reconstruction in studies comparing rehabilitation with and without BFR-t. STUDY DESIGN: Systematic review. Level of evidence, 3. METHODS: A search of English-language human clinical studies published in the past 20 years (2002-2022) was carried out in 5 health sciences databases, involving participants aged 18-65 undergoing rehabilitation for an ACL injury. Outcomes associated with muscle strength, muscle size, and knee-specific patient-reported outcome measures (PROMs) were extracted from studies meeting inclusion criteria and compared. RESULTS: The literature search identified 279 studies, of which 5 met the selection criteria. Two studies suggested that BFR-t rehabilitation after an ACL injury improved knee or thigh muscle strength and muscle size compared with rehabilitation consisting of comparable and higher load resistance training, with two studies suggesting the opposite. The single study measuring PROMs showed improvement compared to traditional rehabilitation, with no difference in muscle strength or size. CONCLUSION: BFR-t after an ACL injury seems to benefit muscle strength, muscle size, and PROM scores compared with standard rehabilitation alone. However, only 1 large study included all these outcomes, which has yet to be replicated in other settings. Further studies utilizing similar methods with a common set of outcome measures are required to confirm the effects of BFR-t on ACL rehabilitation.

2.
J Physiol ; 602(10): 2287-2314, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38619366

RESUMO

The physiological mechanisms determining the progressive decline in the maximal muscle torque production capacity during isometric contractions to task failure are known to depend on task demands. Task-specificity of the associated adjustments in motor unit discharge rate (MUDR), however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee extension tasks to failure. Participants performed a sustained and an intermittent task at 20% and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High-density surface EMG signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During the 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40-50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30% and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80-90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70-80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are contraction modality- and intensity-dependent. KEY POINTS: During prolonged muscle contractions a constant motor output can be maintained by recruitment of additional motor units and adjustments in their discharge rate. Whilst contraction-induced decrements in neuromuscular function are known to depend on task demands, task-specificity of motor unit discharge behaviour adjustments is still unclear. In this study, we tracked and compared discharge activity of several concurrently active motor units in the vastii muscles during different submaximal isometric knee extension tasks to failure, including intermittent vs. sustained contraction modalities performed in the same intensity domain (Experiment 1), and two sustained contractions performed at different intensities (Experiment 2). During each task, motor units modulated their discharge rate in a distinct, biphasic manner, with the modulation pattern depending on contraction intensity and modality. These results provide insight into motoneuronal adjustments during contraction tasks posing different demands on the neuromuscular system.


Assuntos
Contração Isométrica , Humanos , Contração Isométrica/fisiologia , Masculino , Adulto , Feminino , Torque , Adulto Jovem , Músculo Esquelético/fisiologia , Neurônios Motores/fisiologia , Eletromiografia , Músculo Quadríceps/fisiologia , Recrutamento Neurofisiológico/fisiologia
3.
J Therm Biol ; 112: 103442, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36796897

RESUMO

INTRODUCTION: A wide range of cooling vests for heat-strain mitigation purposes during physical work are available on the market. The decision regarding the optimal cooling vest/concept for a specific environment can be challenging by relying solely on the information provided by the manufacturers. The aim of this study was to investigate how different types of cooling vests would manifest/perform in a simulated industrial setting, in a warm and moderately humid environment with low air velocity. METHODS: Ten young males completed six experimental trials, including a control trial (no vest) and five trials with vests of different cooling concepts. Once entering the climatic chamber (ambient temperature: 35 °C, relative humidity: 50 %), participants remained seated for 30 min to induce passive heating, after which they donned a cooling vest and started a 2.5-h of walk at 4.5 km·h-1. During the trial, torso skin temperature (Tsk), microclimate temperature (Tmicro) and relative humidity (RHmicro), as well as core temperature (rectal and gastrointestinal; Tc) and heart rate (HR) were measured. Before and after the walk, participants conducted different cognitive tests and provided subjective ratings throughout the walk. RESULTS: The use of the vests attenuated the increase in HR (103 ± 12 bpm) when compared to control trial (116 ± 17 bpm, p < 0.05). Four vests maintained a lower torso Tsk (31.7 ± 1.5 °C) compared to control trial (36.1 ± 0.5 °C, p < 0.05). Two vests using PCM inserts attenuated the increase in Tc between 0.2 and 0.5 °C in relation to control trial (p < 0.05). Cognitive performance remained unchanged between the trials. Physiological responses were also well reflected in subjective reports. CONCLUSION: Most vests could be considered as an adequate mitigation strategy for workers in industry under the conditions simulated in the present study.


Assuntos
Temperatura Alta , Roupa de Proteção , Masculino , Humanos , Temperatura Cutânea , Temperatura Baixa , Transição de Fase , Frequência Cardíaca/fisiologia , Regulação da Temperatura Corporal/fisiologia
4.
Physiol Rep ; 9(20): e15035, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34665531

RESUMO

PURPOSE: As part of our investigations of intraocular pressure (IOP) as a potential contributing factor to the spaceflight-associated neuro-ocular syndrome using the 6° head-down tilt (6°HDT) bed rest experimental model, we compared the effect of rest and isometric exercise in prone and supine 6°HDT positions on IOP with that observed in the seated position. METHODS: Ten male volunteers (age = 22.5 ± 3.1 yrs) participated in six interventions. All trials comprised a 10-min rest period, a 3-min isometric handgrip exercise at 30% of participant's maximum, and a 10-min recovery period. The trials were conducted under normocapnic (NCAP) or hypercapnic (FI CO2  = 0.01; HCAP) conditions, the latter mimicking the ambient conditions on the International Space Station. IOP, systolic and diastolic pressures, and heart rate (HR) were measured during the trials. RESULTS: Isometric exercise-induced elevations in HR and mean arterial blood pressure. IOP in the prone 6°HDT position was significantly higher (p < 0.001) compared to IOP in supine 6°HDT position and seated trials at all time points. IOP increased with exercise only in a seated HCAP trial (p = 0.042). No difference was observed between trials in NCAP and HCAP. IOP in the prone 6°HDT position was constantly elevated above 21 mmHg, the lower limit for clinical ocular hypertension. CONCLUSIONS: IOP in the prone 6°HDT position was similar to IOP reported in astronauts upon entering microgravity, potentially indicating that prone, rather than supine 6°HDT position might be a more suitable experimental analog for investigating the acute ocular changes that occur in microgravity.


Assuntos
Exercício Físico , Força da Mão , Hipercapnia/fisiopatologia , Pressão Intraocular , Decúbito Ventral , Decúbito Dorsal , Adulto , Repouso em Cama , Decúbito Inclinado com Rebaixamento da Cabeça , Frequência Cardíaca , Humanos , Masculino , Simulação de Ausência de Peso , Adulto Jovem
5.
Ergonomics ; 64(5): 625-639, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33222661

RESUMO

As frequency and severity of heat waves are increasing, personal cooling systems are being considered as a tool to mitigate heat strain in workers in various occupational settings. This study assessed cooling capacities (C; W·h·m-2) of various commercially available vests using different cooling concepts. Measurements were conducted over 8 h in a climatic chamber (Ta: 35 °C, RH: 35 %) using a thermal manikin (Ts: 35 °C). Cooling power (P) and duration of efficient cooling (tc) determined the C value of each vest. Among the cooling concepts the active cooling vests were the most efficient, extracting 331 W·h·m-2, followed by the vests with phase change material (PCM) inserts, hybrid and evaporative vests, extracting a maximum of 164 W·h·m-2, 146 W·h·m-2 and 113 W·h·m-2, respectively. While some vests with PCM inserts provided intense but shorter cooling, evaporative vests provided mild but longer cooling throughout. Practitioner summary: The study assessed the cooling capacity of commercially available vests, using a thermal manikin. The vests present an affordable solution in various occupational settings where air-conditioning is not an option. A range of cooling capacities among different cooling concepts and vests of the same category were noted. Abbreviations: ACVs: air-cooled vests; LCVs: liquid-cooled vests; ECVs: evaporative cooling vests; HCVs: hybrid cooling vests; PCVs: phase-change cooling vests; PCM: phase change material; C: cooling capacity; Rt: thermal resistance; Re: evaporative resistance; Re (%): relative evaporative resistance; P: cooling power; Pmax: maximal cooling power; Pavg: average cooling power; tc: cooling duration; AUC: area under the curve; Ta: ambient temperature; RH: relative humidity; va: chamber air flow; Ts: manikin surface temperature.


Assuntos
Regulação da Temperatura Corporal , Roupa de Proteção , Temperatura Baixa , Temperatura Alta , Humanos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...