Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Hum Reprod ; 38(10): 1961-1969, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37573141

RESUMO

STUDY QUESTION: Do spontaneously conceived (SC) fetuses from subfertile couples show the same signs of cardiac remodeling as those observed after IVF treatments? SUMMARY ANSWER: As opposed to fetuses from IVF, SC fetuses from subfertile couples do not show cardiac remodeling and present a similar cardiac structure and function to those of SC fetuses from fertile couples. WHAT IS KNOWN ALREADY: Subjects conceived by IVF present signs of cardiac remodeling and suboptimal function in utero and during childhood, including larger atria, more globular and thicker ventricles, reduced longitudinal motion, and impaired relaxation as compared to SC individuals from fertile couples. There are no previous publications investigating the independent cardiac programming effects of infertility in SC fetuses from subfertile couples (with time-to-pregnancy (TTP) over 12 months). STUDY DESIGN, SIZE, DURATION: A prospective cohort study of 289 singleton pregnancies exposed and not exposed to subfertility recruited from 2019 to 2021, including 96 SC pregnancies from fertile couples (TTP under 12 months), 97 SC from subfertile couples (TTP over 12 months), and 96 from IVF after fresh embryo transfer. Fetal echocardiography was performed in all pregnancies. Epidemiological data and perinatal outcomes were collected in all pregnancies. The overall attrition rate was 15.7%. PARTICIPANTS/MATERIALS, SETTING, METHODS: SC from subfertile couples and IVF pregnancies were identified as eligible at pregnancy diagnosis, and eligible SC pregnancies from fertile couples who attended our maternal-fetal unit were invited to participate at third trimester, being matched to the other groups by maternal age. Fetal echocardiography was performed at 29-34 weeks of pregnancy to assess cardiac structure and function, and results were adjusted by parental age, maternal smoking status, child's birth order, birthweight centile, gestational age, and estimated fetal weight at scan. MAIN RESULTS AND THE ROLE OF CHANCE: Parental age, ethnicity, BMI, and smoking exposure, median gestational age and estimated fetal weight were similar in all study groups. There were no significant differences in infertility duration or etiology between the subfertile and the IVF populations (TTP: subfertile median 35 months (interquartile range 20-48) versus IVF: 47 (25-61); P-value = 0.051). While both fertile and subfertile SC groups presented similar fetal cardiac results, IVF fetuses showed larger atria (right atria-to-heart ratio: IVF mean 18.9% (SD 3.4) versus subfertile 17.8% (3.5) versus fertile 17.6% (3.3); adjusted P-value < 0.001), more globular ventricles (right ventricular sphericity index: IVF 1.56 (0.25) versus subfertile 1.72 (0.26) versus fertile 1.72 (0.26); <0.001), and thicker myocardial walls (relative wall thickness: IVF 0.86 (0.22) versus subfertile 0.64 (0.13) versus fertile 0.64 (0.18); <0.001). Whereas SC fetuses from fertile and subfertile couples had preserved cardiac function, IVF fetuses showed signs of suboptimal systolic and diastolic function, with reduced tricuspid ring displacement (IVF 7.26 mm (1.07) versus subfertile 8.04 mm (1.18) versus fertile 7.89 mm (1.51); <0.001) and increased left myocardial performance index (IVF 0.49 (0.08) versus subfertile 0.45 (0.09) versus fertile 0.45 (0.10); <0.001). A sub-analysis including only unexplained infertility cases in subfertile SC and IVF groups showed similar results. LIMITATIONS, REASONS FOR CAUTION: The fetal cardiac changes reported here are subclinical, and most of the cardiovascular parameters were within normal ranges. Although echocardiographic changes are recognized as potential cardiovascular risk factors, their association with long-term cardiovascular disease remains to be demonstrated. WIDER IMPLICATIONS OF THE FINDINGS: Subfertility per se does not seem to be associated to fetal cardiac remodeling, which has been previously described in IVF fetuses. Future studies are warranted to further investigate other factors related to the observed fetal cardiac changes associated with ART. STUDY FUNDING/COMPETING INTEREST(S): This project has been partially funded with support from the Erasmus + Programme of the European Union (Framework Agreement number: 2013-0040). This publication reflects the views only of the author, and the Commission cannot be held responsible for any use, which may be made of the information contained therein. Additionally, the research leading to these results has received funding from 'la Caixa' Foundation under grant agreement LCF/PR/GN18/10310003, the Instituto de Salud Carlos III (PI15/00130, PI16/00861, PI17/00675, PI18/00073, INT21/00027)-co-funded by the European Union, Cerebra Foundation for the Brain Injured Child (Carmarthen, Wales, UK) and AGAUR 2017 SGR grant no 1531. The authors have no conflicts of interest to declare. TRIAL REGISTRATION NUMBER: N/A.


Assuntos
Fertilização in vitro , Infertilidade , Gravidez , Criança , Feminino , Humanos , Fertilização in vitro/métodos , Estudos Prospectivos , Peso Fetal , Remodelação Ventricular , Infertilidade/etiologia
2.
Hum Reprod ; 36(10): 2697-2708, 2021 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-34323946

RESUMO

STUDY QUESTION: Do fetuses from frozen embryo transfer (FET) present signs of cardiac remodeling and suboptimal function similar to those observed in fetuses from fresh embryo transfer (ET)? SUMMARY ANSWER: Fetuses from both fresh ET and FET present signs of fetal cardiac remodeling and suboptimal function, with more pronounced changes after fresh ET as compared to FET. WHAT IS KNOWN ALREADY: Our group and others have previously demonstrated that fetuses and children conceived by ARTs present cardiac remodeling and suboptimal function. These fetuses show dilated atria, more globular and thicker ventricles, reduced longitudinal motion, and impaired relaxation. Cardiac changes were already present in utero and persisted after birth. Most of the ART fetuses included in previous publications were from fresh ET. However, singletons from FET have different perinatal outcomes compared to those from fresh ET. There are no previous studies comparing cardiac morphology and function between fetuses following fresh and FET. STUDY DESIGN, SIZE, DURATION: This is a prospective cohort study of 300 singleton pregnancies recruited from 2017 to 2020, including 100 spontaneously conceived (SC) pregnancies, 100 fetuses conceived by IVF with FET, and 100 fetuses conceived by IVF with fresh ET. Fetal structural and functional echocardiography was performed in all pregnancies. PARTICIPANTS/MATERIALS, SETTING, METHODS: Pregnancies conceived by IVF were recruited from a single assisted reproduction center, ensuring homogeneity in IVF stimulation protocols, endometrial preparation for FET, laboratory procedures, and embryo culture conditions. SC pregnancies from fertile couples were selected from the general population and matched to IVF pregnancies by maternal age. Epidemiological and perinatal outcomes were collected in all cases. Fetal echocardiography was performed at 28-33 weeks of pregnancy to assess cardiac structure and function in all pregnancies. All echocardiographic comparisons were adjusted by maternal age, nulliparity, birthweight centile, preeclampsia, and prematurity. MAIN RESULTS AND THE ROLE OF CHANCE: Parental age, ethnicity, body mass index and smoking were similar among the study groups. Median gestational age at echocardiography and estimated fetal weight were similar in all study groups. Both fresh ET and FET groups showed similar fetal echocardiographic changes, with more pronounced features in the fresh ET as compared to FET pregnancies. Fetuses conceived by IVF showed larger atria (right atria-to-heart ratio: fresh ET mean 18.1% (SD 3.2) vs FET 18.0% (3.9) vs SC 17.3% (3.2); linear tendency P-value <0.001), more globular ventricles (right ventricular sphericity index: fresh ET 1.62 (0.29) vs FET 1.61 (0.25) vs SC 1.68 (0.26); <0.001) and thicker myocardial walls (relative wall thickness: fresh ET 0.79 (0.21) vs FET 0.74 (0.22) vs SC 0.65 (0.25); <0.001) as compared to SC pregnancies. Both fresh ET and FET groups also had signs of suboptimal systolic and diastolic function, with reduced tricuspid annular systolic peak velocity (fresh ET 7.17 cm/s (1.22) vs FET 7.41 cm/s (1.19) vs SC 7.58 cm/s (1.32); <0.001) and increased left myocardial performance index (fresh ET 0.53 (0.08) vs FET 0.53 (0.08) vs SC 0.50 (0.09); <0.001) as compared to SC pregnancies. LIMITATIONS, REASONS FOR CAUTION: The cardiac changes reported here are subclinical, with most cardiovascular indexes lying within normal ranges. Although echocardiographic changes are recognized as potential cardiovascular risk factors, their association with the long-term cardiovascular disease remains to be proven. The observed milder fetal cardiac features in FET fetuses cannot condition the choice of this technique and must be considered together with the global perinatal results related to these gestations. WIDER IMPLICATIONS OF THE FINDINGS: The identification of cardiac remodeling in fetuses conceived by IVF with fresh ET and FET represents an opportunity for early detection. Future studies are warranted to study the potential long-term consequences of these findings. STUDY FUNDING/COMPETING INTEREST(S): This project has been partially funded with support from the Erasmus + Programme of the European Union (Framework Agreement number: 2013-0040). This publication reflects the views only of the author, and the Commission cannot be held responsible for any use, which may be made of the information contained therein. Additionally, the research leading to these results has received funding from 'la Caixa' Foundation under grant agreement LCF/PR/GN18/10310003, the Instituto de Salud Carlos III (PI15/00130, PI17/00675, PI18/00073) integrated into the Plan Nacional de I + D+I and cofinanced by ISCIII-Subdirección General de Evaluación and Fondo Europeo de Desarrollo Regional (FEDER) 'Una manera de hacer Europa', Cerebra Foundation for the Brain Injured Child (Carmarthen, Wales, UK) and AGAUR 2017 SGR grant n° 1531. The authors declare no conflicts of interest. TRIAL REGISTRATION NUMBER: N/A.


Assuntos
Transferência Embrionária , Remodelação Ventricular , Criança , Feminino , Fertilização , Fertilização in vitro , Feto , Humanos , Gravidez , Estudos Prospectivos , Estudos Retrospectivos
3.
Ultrasound Obstet Gynecol ; 58(3): 388-397, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32959925

RESUMO

OBJECTIVE: To construct nomograms for fetal cardiac, ventricular and atrial relative size and geometry parameters from 18 to 41 weeks' gestation using a low-risk population of singleton pregnancies. METHODS: This was a prospective cohort study of 602 low-risk singleton pregnancies undergoing comprehensive fetal echocardiography, from 18 to 41 weeks of gestation, to assess fetal cardiac, atrial and ventricular relative size and sphericity, ventricular dominance, wall asymmetry and relative wall thickness. Intra- and interobserver measurement reproducibility was evaluated using intraclass correlation coefficients (ICC). In order to construct reference ranges across pregnancy, parametric regressions were tested to model each measurement against gestational age and estimated fetal weight. The measurements evaluated were: cardiothoracic ratio; atrial-to-heart area ratios; ventricular-to-heart area ratios; cardiac, ventricular and atrial sphericity indices; right-to-left basal and midventricular ratios; septal-to-free wall thickness ratios; and relative wall thickness. RESULTS: Fetal cardiac, ventricular and atrial morphometry for assessing relative size and geometry could be successfully performed in > 95% of the population, with moderate-to-excellent interobserver reproducibility (ICC, 0.623-0.907) and good-to-excellent intraobserver reproducibility (ICC, 0.787-0.938). Cardiothoracic ratio and ventricular right-to-left ratio showed a modest increase throughout gestation. Atrial-to-heart and ventricular-to-heart area ratios, atrial sphericity indices and septal-to-free wall thickness ratios were constant with gestational age. Left and right ventricular basal sphericity indices showed a tendency to decrease at the end of gestation, while left and right midventricular sphericity indices tended to decrease in the second trimester. The cardiac sphericity index and left and right relative wall thickness showed a modest decrease with gestational age. Nomograms across gestation were constructed for all echocardiographic parameters described. CONCLUSIONS: The assessment of cardiac, ventricular and atrial relative size and geometry is feasible and reproducible in the fetus. We provide standardized reference ranges for these parameters throughout gestation, enabling the accurate assessment of cardiac remodeling patterns during fetal life. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Ecocardiografia/estatística & dados numéricos , Coração Fetal/diagnóstico por imagem , Coração Fetal/embriologia , Nomogramas , Ultrassonografia Pré-Natal/estatística & dados numéricos , Adulto , Estudos de Viabilidade , Feminino , Idade Gestacional , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/embriologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Humanos , Tamanho do Órgão , Gravidez , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
4.
BJOG ; 126(2): 291-298, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29673050

RESUMO

OBJECTIVE: To assess the postnatal persistence of fetal cardiovascular remodelling associated with assisted reproductive technologies (ART) in children at 3 years of age. DESIGN: A cohort study of children conceived by ART. SETTING: Maternal-Fetal Medicine Unit, Hospital Clinic Barcelona, Spain. POPULATION SAMPLE: Eighty singleton pregnancies conceived by ART and 80 spontaneously conceived (controls) followed from fetal life up to childhood. METHODS: Cardiovascular evaluation was performed at 3 years of corrected age, including echocardiography, carotid intima-media (cIMT) by ultrasound, and blood pressure. MAIN OUTCOME MEASURES: Postnatal persistence of cardiovascular changes in children conceived by ART. RESULTS: Compared with controls, children conceived by ART showed larger atria (right atrial area: control 4.9 cm2 (0.9) versus ART 5.5 cm2 (0.9), P < 0.001), more globular ventricles (right ventricular sphericity index: control mean 1.8 (SD 0.5) versus ART 1.6 (0.2), P < 0.001), and signs of systolic (tricuspid annular plane systolic excursion: control 18 mm (2) versus ART 16 mm (3), P < 0.001) and diastolic dysfunction (isovolumic relaxation time: control 68 ms (12) versus ART 79 ms (12), P < 0.001). ART children also presented increased systolic blood pressure (control 90 mmHg (6) versus ART 94 mmHg (5), P < 0.003) and cIMT (control 0.52 µm (0.14) versus ART 0.60 µm (0.16), P < 0.001) as compared with those spontaneously conceived. CONCLUSIONS: Cardiovascular changes previously reported in ART fetuses persist postnatally at 3 years of age. These results underscore the importance of future studies for assessing the long-term cardiovascular health associated with ART. TWEETABLE ABSTRACT: Cardiovascular changes described in fetuses conceived by ART, persist in children at 3 years of age.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia/métodos , Técnicas de Reprodução Assistida/efeitos adversos , Remodelação Ventricular , Adulto , Pressão Sanguínea , Doenças Cardiovasculares/etiologia , Espessura Intima-Media Carotídea , Estudos de Casos e Controles , Pré-Escolar , Feminino , Humanos , Masculino , Gravidez , Estudos Prospectivos , Fatores de Risco , Ultrassonografia
5.
Ultrasound Obstet Gynecol ; 51(1): 94-100, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28508519

RESUMO

OBJECTIVE: Recent data suggest that singleton fetuses conceived by assisted reproductive technology (ART) present cardiovascular remodeling that may persist postnatally. Twin pregnancies are more frequent in the ART population and are associated with increased adverse perinatal outcomes, such as hypertensive disorders, gestational diabetes and preterm birth. However, it is unknown whether cardiac remodeling is also present in twin pregnancies conceived by ART. Our aim was to assess the presence of fetal cardiac remodeling and dysfunction in twin pregnancies conceived by ART as compared with those conceived spontaneously (SC). METHODS: This was a prospective cohort study including 50 dichorionic twin fetuses conceived by ART and 50 SC twin fetuses. The study protocol included collection of baseline/perinatal data and a fetal ultrasound examination at 28-30 weeks' gestation, including assessment of estimated fetal weight, fetoplacental Doppler and fetal echocardiography. Measurements of atrial area, atrial/heart ratio, ventricular sphericity index, free wall thickness, mitral and tricuspid annular plane systolic excursions, and systolic and early diastolic peak velocities were assessed. Multilevel analyses were used to compare perinatal and ultrasonographic parameters. Comparisons of echocardiographic variables were adjusted for parental age, paternal body mass index and incidence of pre-eclampsia. RESULTS: Compared with SC twins, ART twin fetuses showed significant cardiac changes, predominantly affecting the right heart, such as dilated atria (right atrial/heart area: 15.7 ± 3.1 vs 18.4 ± 3.2, P < 0.001), more globular ventricles (right ventricular sphericity index: 1.57 ± 0.25 vs 1.41 ± 0.23, P = 0.001) and thicker myocardial walls (septal wall thickness: 2.57 ± 0.45 mm vs 2.84 ± 0.41 mm, P = 0.034) together with reduced longitudinal motion (tricuspid annular plane systolic excursion: 6.36 ± 0.89 mm vs 5.18 ± 0.93 mm, P < 0.001). CONCLUSIONS: ART twin fetuses present signs of cardiac remodeling and dysfunction. These changes are similar to those observed in ART singletons and reinforce the concept of fetal cardiac programing in ART. These results open opportunities for early detection and intervention in infants conceived by ART. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ecocardiografia , Coração Fetal/fisiologia , Gravidez de Gêmeos , Técnicas de Reprodução Assistida , Ultrassonografia Pré-Natal , Remodelação Ventricular/fisiologia , Adulto , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Masculino , Gravidez , Resultado da Gravidez , Estudos Prospectivos , Técnicas de Reprodução Assistida/efeitos adversos , Espanha
6.
Ultrasound Obstet Gynecol ; 50(2): 207-214, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27859818

RESUMO

OBJECTIVE: To identify different cardiac phenotypes among cases of fetal growth restriction (FGR). METHODS: Echocardiography was performed in 126 cases with FGR (birth weight < 10th centile) and 64 appropriate-for-gestational-age (AGA) fetuses. Principal component and cluster analyses were performed to identify different cardiac phenotypes among FGR cases. RESULTS: Three different cardiac phenotypes were identified among the FGR group: globular in 54% of cases, elongated in 29% of cases and hypertrophic in 17% of cases. Those with a globular heart had the lowest median left-ventricular sphericity index (controls, 1.78 (interquartile range (IQR), 1.62-1.97); FGR elongated, 1.92 (IQR, 1.78-2.09); FGR globular, 1.44 (IQR, 1.36-1.52); FGR hypertrophic, 1.65 (IQR, 1.42-1.77); P = 0.001). FGR cases with an elongated left ventricle had nearly normal cardiac dimensions. FGR cases with a hypertrophic phenotype had the highest median left-ventricular wall thickness (controls, 1.22 (IQR, 1.10-1.67) mm/kg; FGR elongated, 1.52 (IQR, 1.28-1.86) mm/kg; FGR globular, 1.65 (IQR, 1.39-1.99) mm/kg; FGR hypertrophic, 3.68 (IQR, 3.45-4.71) mm/kg; P = 0.001) and cardiac dimensions. Globular and elongated phenotypes showed a fetoplacental profile of late-onset FGR, while the hypertrophic phenotype showed signs of early-onset FGR. The hypertrophic group also had the poorest perinatal results, having the lowest birth-weight centile, gestational age at delivery and Apgar score and the highest postnatal blood pressure and aorta intima-media thickness. CONCLUSIONS: FGR induces at least three different cardiac phenotypes, with early-onset FGR cases being associated with a hypertrophic response and worse perinatal outcomes. This cardiac phenotypic classification may improve identification of FGR cases with the highest perinatal and long-term cardiovascular risks. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Coração/diagnóstico por imagem , Estudos de Casos e Controles , Estudos de Coortes , Ecocardiografia , Feminino , Idade Gestacional , Humanos , Fenótipo , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal
7.
Ultrasound Obstet Gynecol ; 50(1): 63-70, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27420642

RESUMO

OBJECTIVE: Fetuses conceived by assisted reproductive technology (ART) and those that are small-for-gestational age (SGA) show cardiovascular remodeling in utero; however, these two conditions are often associated. We aimed to evaluate the differential effect of ART and SGA on fetal cardiac remodeling. METHODS: This was a prospective cohort study of term singleton pregnancies seen at our department between April 2011 and September 2013. The cohort was divided according to fetal growth and mode of conception into the following four groups: 102 appropriate-for-gestational-age (AGA) fetuses conceived spontaneously (controls), 72 AGA fetuses conceived by ART (ART-AGA), 31 SGA fetuses conceived by ART (ART-SGA) and 28 SGA fetuses conceived naturally (Spont-SGA). SGA was defined as birth weight < 10th centile. Fetal echocardiography was performed at 28-32 weeks to assess cardiac dimensions, geometry and function. RESULTS: ART fetuses had dilated atria (mean left atrium-to-heart area ratio: controls, 15 ± 2.7%; ART-AGA, 18 ± 4.1%; Spont-SGA, 14 ± 3.7%) and more globular ventricles (left ventricular sphericity index: controls, 1.77 ± 0.2; ART-AGA, 1.68 ± 0.2; Spont-SGA, 1.72 ± 0.2), with normally sized hearts. In contrast, SGA fetuses had enlarged hearts (cardiothoracic ratio: controls, 24 ± 3%; ART-AGA, 24 ± 4%; Spont-SGA, 29 ± 6%), preserved atrial size, more globular and concentric hypertrophic ventricles (left ventricle relative wall thickness: controls, 0.48 ± 0.17; ART-AGA, 0.54 ± 0.13; Spont-SGA, 0.63 ± 0.23). Both ART and SGA fetuses had decreased longitudinal motion (tricuspid annular ring displacement: controls, 6.5 ± 0.8 mm; ART-AGA, 5.5 ± 0.7 mm; Spont-SGA, 5.9 ± 0.6 mm) and impaired relaxation (left isovolumetric relaxation time: controls, 47.0 ± 7.3 ms; ART-AGA, 50.0 ± 7.9 ms; Spont-SGA, 49.5 ± 9.3 ms). ART-SGA fetuses presented a combination of features from both ART and SGA groups. CONCLUSION: SGA and conception with ART were associated with distinct patterns of fetal cardiac remodeling, supporting the concept that they are independent causes of cardiac programming. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Coração Fetal/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional , Técnicas de Reprodução Assistida , Remodelação Ventricular , Adulto , Estudos de Casos e Controles , Estudos de Coortes , Ecocardiografia , Feminino , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez , Estudos Prospectivos , Espanha , Ultrassonografia Pré-Natal
8.
Ultrasound Obstet Gynecol ; 48(3): 349-56, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26415719

RESUMO

OBJECTIVES: Intrauterine growth restriction is associated with increased cardiovascular risk later in life but the link between fetal disease and postnatal risk is not well-documented. We evaluated longitudinally the association between cardiovascular remodeling in small-for-gestational-age (SGA) fetuses and at 6 months of age. METHODS: A cohort of 80 SGA fetuses (defined by estimated fetal and birth weights < 10(th) centile) delivered > 34 weeks' gestation was compared with 80 normally grown age-matched control fetuses, with follow-up at 6 months of corrected age (i.e. 6 months from estimated date of delivery according to first-trimester crown-rump length). Cardiovascular evaluation included a comprehensive echocardiographic assessment in both fetuses and infants and blood pressure and aortic intima-media thickness (aIMT) measurement in infants. Parameters were adjusted by linear regression analysis for gender, gestational age at delivery, pre-eclampsia, prenatal glucocorticoid exposure, Cesarean delivery, admission to neonatal intensive care unit and body surface area. RESULTS: Both pre- and postnatally, when compared with controls, the SGA group showed a more globular cardiac shape (left sphericity index: controls 2.06 vs SGA 1.87 (P = 0.022) prenatally and 1.92 vs 1.67 (P = 0.007) postnatally), as well as signs of systolic longitudinal dysfunction (systolic annular peak velocity (S'): 7.2 vs 6.3 cm/s (P = 0.003) prenatally and 7.9 vs 6.4 cm/s (P < 0.001) postnatally; tricuspid annular plane systolic excursion: 7.2 vs 6.8 mm (P = 0.015) prenatally and 16.0 vs 14.2 mm (P < 0.001) postnatally) and diastolic dysfunction (left isovolumetric relaxation time: 46 vs 52 ms (P < 0.001) prenatally and 50 vs 57 ms (P = 0.034) postnatally). In addition, infants in the SGA group had increased mean blood pressure (mean: 61 vs 70 mmHg, P < 0.001) and maximum aIMT (0.57 vs 0.66 mm; P < 0.001). CONCLUSIONS: Primary cardiovascular changes are already present in the SGA fetus and persist at 6 months of age. These data support prenatal cardiovascular remodeling as a mechanistic pathway of increased risk later in life in cases of SGA, regardless of Doppler abnormalities. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Doenças Cardiovasculares/fisiopatologia , Sistema Cardiovascular/fisiopatologia , Retardo do Crescimento Fetal/fisiopatologia , Ultrassonografia Pré-Natal , Adulto , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/embriologia , Sistema Cardiovascular/diagnóstico por imagem , Sistema Cardiovascular/embriologia , Espessura Intima-Media Carotídea , Estatura Cabeça-Cóccix , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Estudos Longitudinais , Masculino , Gravidez , Estudos Prospectivos , Fatores de Risco , Remodelação Vascular , Remodelação Ventricular
9.
Ultrasound Obstet Gynecol ; 43(6): 632-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24639072

RESUMO

OBJECTIVE: To compare left myocardial performance index (MPI) values and reproducibility using different settings and ultrasound equipment in order to standardize optimal machine settings. METHODS: Left MPI was prospectively evaluated by one observer performing conventional Doppler in 62 fetuses (28-36 weeks of gestational age) using different settings (changing sweep speed, gain and wall motion filter (WMF)) and two different ultrasound devices (Siemens Antares, Siemens; Voluson 730 Expert, GE Medical Systems). Intraclass coefficients of agreement (ICCs) were calculated using Bland-Altman analysis. RESULTS: Using baseline settings on the Siemens, mean (SD) MPI was 0.44 (0.05) with an ICC of 0.81. Decreasing the sweep speed resulted in decreasing average MPI values (0.43) and decreasing ICC (0.61). Lowering gain also influenced average MPI values (0.46) and ICC (0.76). Raising gain resulted in similar MPI values (0.45) with better ICC (0.90) compared with baseline settings. Raising wall motion filter (WMF) provided the best ICC (0.94) compared with the other settings. Changing the ultrasound equipment resulted in an ICC of 0.64. The optimal settings to achieve the highest reproducibility in measurement of MPI were sweep speed 8, gain 60 dB and WMF 281 Hz for Siemens Antares and sweep speed 5, gain -10 dB and WMF 210 Hz for Voluson 730 Expert. CONCLUSION: Changing ultrasound settings or equipment may affect the calculation and repeatability of measurement of MPI values. Strict standardization of methods decreases the variability of this parameter for fetal cardiac function assessment.


Assuntos
Coração Fetal/fisiologia , Adulto , Ecocardiografia Doppler/métodos , Ecocardiografia Doppler/normas , Feminino , Coração Fetal/diagnóstico por imagem , Idade Gestacional , Humanos , Masculino , Gravidez , Resultado da Gravidez , Estudos Prospectivos , Fluxo Pulsátil/fisiologia , Valores de Referência , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/normas , Artérias Umbilicais/fisiologia
10.
Ultrasound Obstet Gynecol ; 43(6): 625-31, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24272754

RESUMO

OBJECTIVE: To assess carotid and aortic intima-media thickness (IMT) in term small-for-gestational-age (SGA) newborns with and without prenatal signs of severity. METHODS: This prospective study comprised 67 cases diagnosed prenatally and 134 normally grown newborns. Cases were subclassified into SGA with no signs of severity and those with signs of severity, defined as a birth weight below the 3(rd) percentile or abnormal uterine artery Doppler or cerebroplacental ratio. Blood pressure and vascular IMT were evaluated. RESULTS: SGA newborns showed a non-significant trend for higher values of blood pressure. IMT values were significantly increased in SGA newborns, with and without signs of severity, compared with controls. The magnitude of the increase was higher in SGA newborns with signs of severity. CONCLUSIONS: Vascular IMT was increased in SGA newborns, irrespective of the presence or absence of prenatal signs of severity. This finding challenges the notion of 'constitutionally small' SGA, and supports the premise that the majority of SGA newborns have true growth restriction and suffer fetal cardiovascular programming.


Assuntos
Retardo do Crescimento Fetal/fisiopatologia , Recém-Nascido Pequeno para a Idade Gestacional/fisiologia , Análise de Variância , Aorta/patologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/patologia , Pressão Sanguínea/fisiologia , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/patologia , Espessura Intima-Media Carotídea , Estudos de Casos e Controles , Feminino , Retardo do Crescimento Fetal/patologia , Humanos , Recém-Nascido , Variações Dependentes do Observador , Insuficiência Placentária/patologia , Insuficiência Placentária/fisiopatologia , Gravidez , Estudos Prospectivos , Túnica Íntima/patologia , Túnica Média/patologia
11.
Ultrasound Obstet Gynecol ; 42(2): 175-81, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23280816

RESUMO

OBJECTIVE: To compare the ability of two different methods for longitudinal annular motion measurement, M-mode and tissue Doppler imaging (TDI), to demonstrate cardiac dysfunction in intrauterine-growth-restricted (IUGR) fetuses. METHODS: Cardiac longitudinal annular motion in the basal free wall of the left ventricle (mitral annulus), interventricular septum and tricuspid annulus was assessed in 23 early-onset IUGR cases and 43 controls by TDI (annular peak velocities) and M-mode (displacement). RESULTS: All annular parameters were significantly decreased in the IUGR group with respect to controls using both methods. M-mode showed a trend towards equal performance as classifier between cases and controls, as compared to TDI, mainly in the tricuspid annulus. CONCLUSIONS: Both M-mode and TDI demonstrate annular motion changes and consequently cardiac dysfunction in IUGR fetuses. M-mode imaging is simpler to perform and could be as sensitive as TDI for detecting subtle changes.


Assuntos
Retardo do Crescimento Fetal/fisiopatologia , Coração Fetal/fisiopatologia , Cardiopatias/fisiopatologia , Ecocardiografia Doppler/métodos , Feminino , Coração Fetal/embriologia , Cardiopatias/diagnóstico por imagem , Cardiopatias/embriologia , Septos Cardíacos/embriologia , Septos Cardíacos/fisiologia , Ventrículos do Coração/embriologia , Humanos , Valva Mitral/embriologia , Valva Mitral/fisiologia , Movimento/fisiologia , Valva Tricúspide/embriologia , Valva Tricúspide/fisiologia , Ultrassonografia Pré-Natal/métodos , Função Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...