Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 23(1): 249, 2023 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-37481588

RESUMO

BACKGROUND: In patients undergoing high-risk surgery, it is recommended to titrate fluid administration using stroke volume or a dynamic variable of fluid responsiveness (FR). However, this strategy usually requires the use of a hemodynamic monitor and/or an arterial catheter. Recently, it has been shown that variations of central venous pressure (ΔCVP) during an alveolar recruitment maneuver (ARM) can predict FR and that there is a correlation between CVP and peripheral venous pressure (PVP). This prospective study tested the hypothesis that variations of PVP (ΔPVP) induced by an ARM could predict FR. METHODS: We studied 60 consecutive patients scheduled for high-risk abdominal surgery, excluding those with preoperative cardiac arrhythmias or right ventricular dysfunction. All patients had a peripheral venous catheter, a central venous catheter and a radial arterial catheter linked to a pulse contour monitoring device. PVP was always measured via an 18-gauge catheter inserted at the antecubital fossa. Then an ARM consisting of a standardized gas insufflation to reach a plateau of 30 cmH2O for 30 s was performed before skin incision. Invasive mean arterial pressure (MAP), pulse pressure, heart rate, CVP, PVP, pulse pressure variation (PPV), and stroke volume index (SVI) were recorded before ARM (T1), at the end of ARM (T2), before volume expansion (T3), and one minute after volume expansion (T4). Receiver-operating curves (ROC) analysis with the corresponding grey zone approach were performed to assess the ability of ∆PVP (index test) to predict FR, defined as an ≥ 10% increase in SVI following the administration of a 4 ml/kg balanced crystalloid solution over 5 min. RESULTS: ∆PVP during ARM predicted FR with an area under the ROC curve of 0.76 (95%CI, 0.63 to 0.86). The optimal threshold determined by the Youden Index was a ∆PVP value of 5 mmHg (95%CI, 4 to 6) with a sensitivity of 66% (95%CI, 47 to 81) and a specificity of 82% (95%CI, 63 to 94). The AUC's for predicting FR were not different between ΔPVP, ΔCVP, and PPV. CONCLUSION: During high-risk abdominal surgery, ∆PVP induced by an ARM can moderately predict FR. Nevertheless, other hemodynamic variables did not perform better.


Assuntos
Cateteres de Demora , Humanos , Estudos Prospectivos , Pressão Venosa , Pressão Sanguínea , Pressão Venosa Central
2.
BMC Anesthesiol ; 22(1): 269, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35999508

RESUMO

BACKGROUND: Maintaining a constant driving pressure during a prolonged sigh breath lung recruitment manoeuvre (LRM) from 20 to 45 cmH20 peak inspiratory pressure in mechanically ventilated patients has been shown to be a functional test to predict fluid responsiveness (FR) when using a linear regression model of hemodynamic parameters, such as central venous pressure (CVP) and pulse pressure (PP). However, two important limitations have been raised, the use of high ventilation pressures and a regression slope calculation that is difficult to apply at bedside. This ancillary study aimed to reanalyse absolute variations of CVP (ΔCVP) and PP (ΔPP) values at lower stages of the LRM, (40, 35, and 30 cm H20 of peak inspiratory pressure) for their ability to predict fluid responsiveness. METHODS: Retrospective analysis of a prospective study data set in 18 mechanically ventilated patients, in an intensive care unit. CVP, systemic arterial pressure parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500 mL crystalloid volume expansion. Patients were considered as fluid responders if SV increased more than 10%. Receiver-operating curves (ROC) analysis with the corresponding grey zone approach were performed. RESULTS: Areas under the ROC to predict fluid responsiveness for ΔCVP and ΔPP were not different between the successive stepwise increase of inspiratory pressures [0.88 and 0.89 for ΔCVP at 45 and 30 cm H20 (P = 0.89), respectively, and 0.92 and 0.95 for ΔPP at 45 and 30 cm H20, respectively (P = 0.51)]. Using a maximum of 30 cmH2O inspiratory pressure during the LRM, ΔCVP and ΔPP had a threshold value to predict fluid responsiveness of 2 mmHg and 4 mmHg, with sensitivities of 89% and 89% and specificities of 67% and 89%, respectively. Combining ΔPP and ΔCVP decreased the proportion of the patients in the grey zone from 28 to 11% and showed a sensitivity of 88% and a specificity of 83%. CONCLUSIONS: A stepwise PEEP elevation recruitment manoeuvre of up to 30 cm H20 may predict fluid responsiveness as well as 45 cm H20. The combination of ΔPP and ΔCVP optimizes the categorization of responder and non-responder patients.


Assuntos
Hidratação , Respiração Artificial , Pressão Sanguínea , Pressão Venosa Central , Hemodinâmica , Humanos , Pulmão , Estudos Prospectivos , Estudos Retrospectivos , Volume Sistólico
3.
BMC Anesthesiol ; 22(1): 4, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34979928

RESUMO

OBJECTIVE: Assessment of fluid responsiveness is problematic in intensive care unit patients. Lung recruitment maneuvers (LRM) can be used as a functional test to predict fluid responsiveness. We propose a new test to predict fluid responsiveness in mechanically ventilated patients by analyzing the variations in central venous pressure (CVP) and systemic arterial parameters during a prolonged sigh breath LRM without the use of a cardiac output measuring device. DESIGN: Prospective observational cohort study. SETTING: Intensive Care Unit, Saint-Etienne University Central Hospital. PATIENTS: Patients under mechanical ventilation, equipped with invasive arterial blood pressure, CVP, pulse contour analysis (PICCO™), requiring volume expansion, with no right ventricular dysfunction. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: CVP, systemic arterial parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500 mL fluid expansion to asses fluid responsiveness. 25 patients were screened and 18 patients analyzed. 9 patients were responders to volume expansion and 9 were not. Evaluation of hemodynamic parameters suggested the use of a linear regression model. Slopes for systolic arterial pressure, pulse pressure (PP), CVP and SV were all significantly different between responders and non-responders during the pressure increase phase of LRM (STEP-UP) (p = 0.022, p = 0.014, p = 0.006 and p = 0.038, respectively). PP and CVP slopes during STEP-UP were strongly predictive of fluid responsiveness with an AUC of 0.926 (95% CI, 0.78 to 1.00), sensitivity = 100%, specificity = 89% and an AUC = 0.901 (95% CI, 0.76 to 1.00), sensibility = 78%, specificity = 100%, respectively. Combining sensitivity of PP and specificity of CVP, prediction of fluid responsiveness can be achieved with 100% sensitivity and 100% specificity (AUC = 0.96; 95% CI, 0.90 to 1.00). One patient showed inconclusive values using the grey zone approach (5.5%). CONCLUSIONS: In patients under mechanical ventilation with no right heart dysfunction, the association of PP and CVP slope analysis during a prolonged sigh breath LRM seems to offer a very promising method for prediction of fluid responsiveness without the use and associated cost of a cardiac output measurement device. TRIAL REGISTRATION: NCT04304521 , IRBN902018/CHUSTE. Registered 11 March 2020, Fluid responsiveness predicted by a stepwise PEEP elevation recruitment maneuver in mechanically ventilated patients (STEP-PEEP).


Assuntos
Cuidados Críticos/métodos , Hidratação/métodos , Pulmão/fisiologia , Respiração Artificial/métodos , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/métodos , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...