1.
Pregnancy Hypertens ; 35: 30-31, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38118334

RESUMO

We performed longitudinal examinations of the arterial retinal microvasculature using Adaptive Optics Retinal Imaging in a 30-year-old healthy woman with twin pregnancy from the 23rd week of gestation (wog) to three days postpartum. Two blinded graders recorded the average wall-to-lumen ratio (WLR) of the examined retinal artery. There was a significant increase in the mean WLR over the course of pregnancy followed by a decreasing WLR from the 37th wog. The demonstrated changes in WLR may be an expression of vascular remodeling and adaptation to volume load which indicates that pregnancy can be viewed as a cardiovascular stress test.


Assuntos
Hipertensão , Pré-Eclâmpsia , Artéria Retiniana , Feminino , Humanos , Gravidez , Adulto , Pressão Sanguínea , Coração
2.
Biomed Opt Express ; 14(6): 2645-2657, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342721

RESUMO

The phenomenon of retinal vein pulsation is still not a deeply understood topic in retinal hemodynamics. In this paper, we present a novel hardware solution for recording retinal video sequences and physiological signals using synchronized acquisition, we apply the photoplethysmographic principle for the semi-automatic processing of retinal video sequences and we analyse the timing of the vein collapse within the cardiac cycle using of an electrocardiographic signal (ECG). We measured the left eyes of healthy subjects and determined the phases of vein collapse within the cardiac cycle using a principle of photoplethysmography and a semi-automatic image processing approach. We found that the time to vein collapse (Tvc) is between 60 ms and 220 ms after the R-wave of the ECG signal, which corresponds to 6% to 28% of the cardiac cycle. We found no correlation between Tvc and the duration of the cardiac cycle and only a weak correlation between Tvc and age (0.37, p = 0.20), and Tvc and systolic blood pressure (-0.33, p = 0.25). The Tvc values are comparable to those of previously published papers and can contribute to the studies that analyze vein pulsations.

3.
Biomed Opt Express ; 14(2): 945-970, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874506

RESUMO

This work presents a novel fully automated method for retinal analysis in images acquired with a flood illuminated adaptive optics retinal camera (AO-FIO). The proposed processing pipeline consists of several steps: First, we register single AO-FIO images in a montage image capturing a larger retinal area. The registration is performed by combination of phase correlation and the scale-invariant feature transform method. A set of 200 AO-FIO images from 10 healthy subjects (10 images from left eye and 10 images from right eye) is processed into 20 montage images and mutually aligned according to the automatically detected fovea center. As a second step, the photoreceptors in the montage images are detected using a method based on regional maxima localization, where the detector parameters were determined with Bayesian optimization according to manually labeled photoreceptors by three evaluators. The detection assessment, based on Dice coefficient, ranges from 0.72 to 0.8. In the next step, the corresponding density maps are generated for each of the montage images. As a final step, representative averaged photoreceptor density maps are created for the left and right eye and thus enabling comprehensive analysis across the montage images and a straightforward comparison with available histological data and other published studies. Our proposed method and software thus enable us to generate AO-based photoreceptor density maps for all measured locations fully automatically, and thus it is suitable for large studies, as those are in pressing need for automated approaches. In addition, the application MATADOR (MATlab ADaptive Optics Retinal Image Analysis) that implements the described pipeline and the dataset with photoreceptor labels are made publicly available.

4.
J Biophotonics ; 15(9): e202200094, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35604408

RESUMO

Multispectral imaging is used in various applications including astronomy, industry and agriculture. In retinal imaging, the single-shot multispectral image stack is typically acquired and analyzed. This multispectral analysis can provide information on various structural or metabolic properties. This paper describes the multispectral improvement of a video-ophthalmoscope, which can acquire retinal video sequences of the optic nerve head and peripapillary area using various spectral light illumination. The description of the multispectral video imaging is provided and several applications are described. These applications include multispectral retinal photoplethysmography, visualization of spontaneous vein pulsation and multispectral RGB image generation.


Assuntos
Iluminação , Disco Óptico , Tecnologia de Fibra Óptica , Oftalmoscópios , Oftalmoscopia/métodos , Disco Óptico/diagnóstico por imagem , Retina/diagnóstico por imagem , Retina/fisiologia
5.
Ultramicroscopy ; 225: 113283, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33906009

RESUMO

Inspired by the standard computed tomography, a new method of 3D X-ray imaging embedded in FIB-SEM microscope is proposed. The unique combination of TEM-like specimen stage enabling in lens STEM detection (referred to as CompuStage), nanomanipulator (referred to as EasyLift) facilitating in-situ sample transfer from bulk sample to TEM-like stage and pixelated in-situ Timepix X-ray detector in Helios G4 FX FIB-SEM system offers an unprecedented workflow. Motivated by common circular CT scan known from microCT world, the object under study is placed on CompuStage rod which enables two possible rotation (in TEM/SEM terminology called tilt) movements - α-tilt - rotation of the CompuStage rod around its axis, and ß-tilt - rotation around axis perpendicular to CompuStage rod. ß-tilt rotation enables a circular movement of the sample while α-tilt sets the correct position of sample with respect to target and detector. Thin metal lamella of suitable material welded to EasyLift manipulator needle is used as an X-ray target. The final target-sample geometry - position, distance - can be fine-tuned using position control of CompuStage and EasyLift and in-situ monitored by SEM. Both sample and target can also be easily prepared in-situ. Radiographs are recorded by Timepix detector with inherent noise-free operation and energy filtration. For the 3D reconstruction standard microCT reconstruction algorithm is used with the procedure adjusted for the format and quality of nanoCT images. The experiments were carried out on Helios G4 FX DualBeam using titanium and tungsten targets and various semiconductor samples. The ultimate resolution of the proposed method in orders of tens of nanometers was achieved both by the possibility of close target to sample positioning and of adjustment of primary beam energy down to low energies reducing the interaction volume in the target. Since the lower energy radiation is well suited for life-science, the method was also tested on several bio-samples using silver target. The silver target, thanks to its massive low energy Lα line, allowed to distinguish subtle structures in the resin embedded stained mouse brain and also to observe and reconstruct canaliculi in the mouse bone (earlier reported by Dierolf et al. 2010, Nature 467 436).


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Microscopia Eletrônica de Varredura , Microtomografia por Raio-X , Algoritmos , Animais , Fêmur/ultraestrutura , Camundongos , Microscopia Eletrônica de Varredura/instrumentação , Microscopia Eletrônica de Varredura/métodos , Imagens de Fantasmas , Microtomografia por Raio-X/instrumentação , Microtomografia por Raio-X/métodos
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 4721-4724, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946916

RESUMO

The fundus observation by ophthalmoscope is a non-invasive approach for diagnosis of various retinal diseases. The vein and artery pulsation are usually clearly apparent on fundus and might be also important for medical practice. Thus our method focuses on these changes and analyzes the time delay between the pulsation signal detected in the vein and the artery region. Data acquired by an experimental video-ophthalmoscope from five subjects with no eye diseases are analyzed. The analysis is based on the selection of artery and vein regions of interest and computation of averaged brightness within these regions for each frame. These extracted signals are filtered, interpolated and the trend is eliminated. Finally, the delays between artery and vein pulsation signals are determined using phase spectra. The measured delays are in the range of 15 to 95 ms, which is comparable with other published results.


Assuntos
Fundo de Olho , Oftalmoscópios , Retina/diagnóstico por imagem , Artéria Retiniana/diagnóstico por imagem , Veia Retiniana/diagnóstico por imagem , Humanos , Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...