Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
J Otolaryngol Head Neck Surg ; 47(1): 38, 2018 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-29801509

RESUMO

BACKGROUND: Providing adequate ventilation may remain complex in patients with severe proximal laryngotracheal stenosis, especially when the airway is shared with the surgeon during tracheal resection surgery. We describe an effective alternative to standard endotracheal intubation using a Rüsch flexible intubation guide catheter. METHODS: In two patients undergoing tracheal repair surgery, we failed to insert a 5.0 inner diameter endotracheal tube (6.9 mm outer diameter) or a 6.0 mm outer diameter endoscope through the laryngotracheal stenosis. However, using indirect laryngoscopy, a 6.0 outer diameter Rüsch flexible intubation guide catheter was passed successfully through the vocal cords and then through the stenosis. Controlled ventilation was achieved by means of the Rüsch guide, provided with its two large Murphy's eyes. When the trachea was opened, the Rüsch guide was removed just enough for the surgeons to place a Montandon tracheal tube, at that point taking over ventilation. A 7.0 inner diameter endotracheal cuffed tube had been inserted onto the Rüsch guide and left pending upstream from the vocal cords. Once the posterior tracheal wall was sutured, this endotracheal cuffed tube was slid along the Rüsch guide through the vocal cords with the cuff placed beyond the tracheal sutures. RESULTS: Controlled ventilation through the Rüsch flexible intubation guide catheter showed satisfying and stable ventilatory parameters in both patients. Inspiratory pressures of 25-30 mmHg were enough to reach adequate tidal volumes around 450 ml. End tidal CO2 was kept between 35 and 40 mmHg (PaCO2 showed similar values). Standard endotracheal intubation at the end of the tracheal resection was easy and safe thanks to the Rüsch guide still in place between the vocal cords. CONCLUSIONS: We suggest an effective and reliable method using a Rüsch flexible intubation guide catheter for airway management in patients suffering from laryngotracheal stenosis in the setting of tracheal repair surgery.


Assuntos
Catéteres , Intubação Intratraqueal/instrumentação , Laringoestenose/cirurgia , Estenose Traqueal/cirurgia , Adulto , Idoso , Feminino , Humanos , Intubação Intratraqueal/métodos , Respiração Artificial
5.
J Clin Anesth ; 32: 142-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27290963

RESUMO

INTRODUCTION: The authors modified an adult jet ventilation injector (Hunsaker Mon-Jet Ventilation Tube(®)) to be able to provide transglottal high-frequency jet ventilation (HFJV) in small children undergoing laryngeal procedures with CO2 laser. METHODS AND MATERIAL: Retrospective review of the anesthetic records of all children younger than 2years undergoing transglottal HFJV for CO2 laser laryngeal procedures using this modified adult injector between 2006 and 2013. RESULTS: Nine children (5 boys, 4 girls) were identified who underwent a total of 20 procedures. Mean age was 7.4 ± 6.9months, and mean weight was 6 ± 2.8 kg. No complications were observed with the use of HFJV or this modified injector. CONCLUSION: In experienced hands, this modified injector ensures excellent visibility and field access to the surgeon as well as adequate ventilation during laryngeal laser surgery in infants.


Assuntos
Ventilação em Jatos de Alta Frequência/métodos , Laringe/cirurgia , Terapia a Laser/métodos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
6.
Neurosurgery ; 63(3): 412-24; discussion 424-6, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18812952

RESUMO

OBJECTIVE: A twin neurosurgical magnetic resonance imaging (MRI) suite with 3-T intraoperative MRI (iMRI) was developed to be available to neurosurgeons for iMRI and for independent use by radiologists. METHODS: The suite was designed with one area dedicated to neurosurgery and the other to performing MRI under surgical conditions (sterility and anesthesia). The operating table is motorized, enabling transfer of the patient into the MRI system. These two areas can function independently, allowing the MRI area to be used for nonsurgical cases. We report the findings from the first 21 patients to undergo scheduled neurosurgery with iMRI in this suite (average age, 51 +/- 24 yr; intracranial tumor, 18 patients; epilepsy surgery, 3 patients). RESULTS: Twenty-six iMRI examinations were performed, 3 immediately before surgical incision, 9 during surgery (operative field partially closed), and 14 immediately postsurgery (operative field fully closed but patient still anesthetized and draped). Minor technical dysfunctions prolonged 10 iMRI procedures; however, no serious iMRI-related incidents occurred. Twenty-three iMRI examinations took an average of 78 +/- 20 minutes to perform. In three patients, iMRI led to further tumor resection because removable residual tumor was identified. Complete tumor resection was achieved in 15 of the 18 cases. CONCLUSION: The layout of the new complex allows open access to the 3-T iMRI system except when it is in use under surgical conditions. Three patients benefited from the iMRI examination to achieve total resection. No permanent complications were observed. Therefore, the 3-T iMRI is feasible and appears to be a safe tool for intraoperative surgical planning and assessment.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Monitorização Intraoperatória/métodos , Salas Cirúrgicas/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/efeitos adversos , Monitorização Intraoperatória/instrumentação , Neuronavegação/efeitos adversos , Neuronavegação/instrumentação , Neuronavegação/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/instrumentação , Procedimentos Neurocirúrgicos/métodos , Estudos Prospectivos , Equipamentos Cirúrgicos/efeitos adversos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...