Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Radiat Prot Dosimetry ; 118(2): 219-26, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16513818

RESUMO

One of the objectives of the European Sixth Framework integrated project MAESTRO is to perform an assessment of risk due to various radiotherapy modalities, regarding secondary tumour induction. Initially, the study will focus on cancer of the prostate and the present work represents the first step towards that goal. One of the intended tools, to be used in the assessment, is the Monte Carlo radiation transport code ORANGE. A validation of the ORANGE code's capability to tally dose on a grid superimposed on an existing MCNP geometry is given. Preliminary results on the dose distribution due to conventional radiotherapy treatment of prostate cancer are discussed. Two mathematical models of the patient are proposed and the clinical relevance of the ADAM phantom is investigated. A problem in comparing average doses provided by commercial treatment planning systems and those calculated with Monte Carlo is noticed. The two proposed models are shown to receive a lower dose and average energy deposition than a 'real' patient.


Assuntos
Neoplasias Induzidas por Radiação/diagnóstico , Neoplasias/radioterapia , Radioterapia/métodos , Algoritmos , Europa (Continente) , Humanos , Masculino , Modelos Teóricos , Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Medição de Risco , Software
3.
Phys Med Biol ; 50(4): 625-41, 2005 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15773624

RESUMO

This study presents data for the verification of ORANGE, a fast MCNP-based dose engine for radiotherapy treatment planning. In order to verify the new algorithm, it has been benchmarked against DOSXYZ and against measurements. For the benchmarking, first calculations have been done using the ICCR-XIII benchmark. Next, calculations have been done with DOSXYZ and ORANGE in five different phantoms (one homogeneous, two with bone equivalent inserts and two with lung equivalent inserts). The calculations have been done with two mono-energetic photon beams (2 MeV and 6 MeV) and two mono-energetic electron beams (10 MeV and 20 MeV). Comparison of the calculated data (from DOSXYZ and ORANGE) against measurements was possible for a realistic 10 MV photon beam and a realistic 15 MeV electron beam in a homogeneous phantom only. For the comparison of the calculated dose distributions and dose distributions against measurements, the concept of the confidence limit (CL) has been used. This concept reduces the difference between two data sets to a single number, which gives the deviation for 90% of the dose distributions. Using this concept, it was found that ORANGE was always within the statistical bandwidth with DOSXYZ and the measurements. The ICCR-XIII benchmark showed that ORANGE is seven times faster than DOSXYZ, a result comparable with other accelerated Monte Carlo dose systems when no variance reduction is used. As shown for XVMC, using variance reduction techniques has the potential for further acceleration. Using modern computer hardware, this brings the total calculation time for a dose distribution with 1.5% (statistical) accuracy within the clinical range (less then 10 min). This means that ORANGE can be a candidate for a dose engine in radiotherapy treatment planning.


Assuntos
Algoritmos , Modelos Biológicos , Método de Monte Carlo , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Software , Carga Corporal (Radioterapia) , Simulação por Computador , Fracionamento da Dose de Radiação , Humanos , Modelos Estatísticos , Dosagem Radioterapêutica , Eficiência Biológica Relativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...