Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 14(5): 768-77, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-14986055

RESUMO

The purpose was to evaluate supine/left decubitus as an alternative to supine/prone scanning in computed tomographic colonography (CT colonography). Fifty patients were randomised to supine/prone, another 50 to supine/left decubitus scanning. Patients were scanned using a single-slice CT scanner. The colon was divided into eight segments. Comparisons of distension, breathing artefacts, residus and polyp detection were made between the two groups as well as between the different positions. Adequate distension was found in approximately 85, 97 and 95% of segments in the supine, prone and left decubitus positions, respectively. Combined scanning increased the percentage of adequate distension to 98.5% for prone-supine and 97.7% for left decubitus-supine scanning ( P<0.0005 compared to supine, P=0.001 compared to left decubitus and P=0.046 compared to prone scanning). Absence of residual material was found in approximately 62.7, 69.7 and 64% of segments in the supine, prone and left decubitus positions, respectively. Combined scanning increased this percentage to approximately 99% for both groups. No significant differences towards distension or residual material were found between combined supine-prone or supine-left decubitus scanning. In the supine-prone group, combined scanning additionally revealed four lesions and improved conspicuity in two cases of stalked polyps. In the supine-left decubitus group, combined scanning additionally revealed two lesions and improved conspicuity in one stalked polyp. There were significantly fewer breathing artefacts with left decubitus scanning than prone scanning ( P=0.005). A strong positive correlation was found between breathing artefacts and the age of patients in both patient groups. Colonic distension and preparation is improved by using supine and prone or supine and left decubitus scanning in combination, with a subsequent improved polyp detection. There were no significant differences between the two scanning protocols. Prone scanning, however, is hampered by breathing artefacts, especially in the elderly. Therefore, supine-left decubitus scanning is considered a valuable alternative to supine-prone scanning for the elderly.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Postura/fisiologia , Adulto , Fatores Etários , Idoso , Artefatos , Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Decúbito Ventral/fisiologia , Estudos Prospectivos , Respiração , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Decúbito Dorsal/fisiologia
2.
Radiology ; 224(2): 393-403, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12147834

RESUMO

PURPOSE: To compare reduced colonic cleansing based on dietary fecal tagging (FT) with standard (non-FT) colonic cleansing with regard to patient acceptance, sensitivity, and specificity. MATERIALS AND METHODS: In 50 patients (FT group), FT was performed by means of diet, magnesium citrate, and a barium suspension. In another 50 patients (non-FT group), preparation was based on polyethylene glycol administration. All patients underwent conventional colonoscopy after computed tomographic (CT) colonography. Sensitivity and specificity for polyp detection were calculated by using conventional colonography as the reference standard. At CT colonography, fecal residue was evaluated. Patients were interviewed to determine discomfort, side effects, sleep quality, final opinion on examination comfort, and whether they would be reluctant to undergo the same examination again. RESULTS: FT left more fecal residue but improved differentiation from polyps (FT specificity, 88% [30 of 34 patients]; non-FT, 77% [23 of 30 patients]). Sensitivities were comparable: FT, 88% (14 of 16 patients); non-FT, 85% (17 of 20 patients). FT significantly reduced discomfort, side effects, and sleep disturbance, and resulted in an improved final opinion of how comfortable the examination was (P <.05). Although FT improved patient willingness to repeat the examination, this improvement was not statistically significant (P >.05). CONCLUSION: FT offers the patient a well-tolerated preparation and improves specificity, with improved differentiation of polyps from residual stool.


Assuntos
Compostos de Bário , Catárticos/administração & dosagem , Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Dieta , Fezes , Tomografia Computadorizada por Raios X , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Compostos de Bário/efeitos adversos , Bisacodil/administração & dosagem , Catárticos/efeitos adversos , Ácido Cítrico/administração & dosagem , Pólipos do Colo/diagnóstico , Colonoscopia , Meios de Contraste/efeitos adversos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Cooperação do Paciente , Satisfação do Paciente , Polietilenoglicóis/administração & dosagem , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Supositórios , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...