Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Neuroradiol J ; 32(5): 317-327, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31282311

RESUMO

PURPOSE: The purpose of this preliminary study is to apply diffusional kurtosis imaging to assess the early response of recurrent glioblastoma to bevacizumab treatment. METHODS: This prospective cohort study included 10 patients who had been diagnosed with recurrent glioblastoma and scheduled to receive bevacizumab treatment. Diffusional kurtosis images were obtained from all the patients 0-7 days before (pre-bevacizumab) and 28 days after (post-bevacizumab) initiating bevacizumab treatment. The mean, 10th, and 90th percentile values were derived from the histogram of diffusional kurtosis imaging metrics in enhancing and non-enhancing lesions, selected on post-contrast T1-weighted and fluid-attenuated inversion recovery images. Correlations of imaging measures with progression-free survival and overall survival were evaluated using Spearman's rank correlation coefficient. The significance level was set at P < 0.05. RESULTS: Higher pre-bevacizumab non-enhancing lesion volume was correlated with poor overall survival (r = -0.65, P = 0.049). Higher post-bevacizumab mean diffusivity and axial diffusivity (D∥, D∥10% and D∥90%) in non-enhancing lesions were correlated with poor progression-free survival (r = -0.73, -0.83, -0.71 and -0.85; P < 0.05). Lower post-bevacizumab axial kurtosis (K∥10%) in non-enhancing lesions was correlated with poor progression-free survival (r = 0.81, P = 0.008). CONCLUSIONS: This preliminary study demonstrates that diffusional kurtosis imaging metrics allow the detection of tissue changes 28 days after initiating bevacizumab treatment and that they may provide information about tumor progression.


Assuntos
Antineoplásicos Imunológicos/uso terapêutico , Bevacizumab/uso terapêutico , Neoplasias Encefálicas/tratamento farmacológico , Glioblastoma/tratamento farmacológico , Recidiva Local de Neoplasia/tratamento farmacológico , Adulto , Idoso , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Imagem de Difusão por Ressonância Magnética , Feminino , Glioblastoma/patologia , Glioblastoma/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/cirurgia , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Resultado do Tratamento
2.
IEEE J Transl Eng Health Med ; 5: 3800204, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29285420

RESUMO

Qualitative assessments of the blink reflex are used clinically to assess neurological status in critical care, operating room, and rehabilitative settings. Despite decades of literature supporting the use of quantitative measurements of the blink reflex in the evaluation of multiple neurological disorders, clinical adoption has failed. Thus, there remains an unmet clinical need for an objective, portable, non-invasive metric of neurological health that can be used in a variety of settings. We have developed a high-speed videography-based device to trigger, record, and analyze a blink reflex. A pilot study was performed to compare the device's measurements to the published literature of electromyographic measurements, currently the gold standard. The study results indicate that the device is a viable tool to obtain fast, objective, and quantitative metrics of a blink reflex, and has promise as a non-invasive diagnostic assessment of neurological health.

3.
Radiology ; 276(3): 706-14, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25786157

RESUMO

PURPOSE: To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. MATERIALS AND METHODS: By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. RESULTS: Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). CONCLUSION: The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.


Assuntos
Vasos Coronários , Processamento de Imagem Assistida por Computador , Stents , Tomografia Computadorizada por Raios X , Algoritmos , Imagens de Fantasmas , Desenho de Prótese
4.
Med Image Anal ; 13(3): 519-29, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19332378

RESUMO

Creation of a transjugular intrahepatic portosystemic shunt (TIPS) requires passage of a needle toward a moving target that is only seen transiently by X-ray prior to needle passage. Intraoperative, 3D target localization would facilitate target access and improve the safety of the procedure. The clinical assumption is that patients undergoing the TIPS procedure possess rigid, cirrhotic livers that undergo only intraoperative translation without significant deformation or rotation. Based upon this assumption, we hypothesize that the position of any unseen, 3D target point within the liver can be determined intraoperatively by precalculation of the relative positions of the target point to a different 3D point that can be tracked intraoperatively. This paper examines this hypothesis using intraoperatively acquired, biplane, X-ray images of seven patients. In six, we tracked the effects of cardiac and respiratory motion, and in three the effects of needle pressure. Methods involved reconstruction of 3D vessel bifurcation and other trackable intrahepatic points from biplane angiograms, measurement of liver deformation by examining changing distances between these 3D points over time, and comparison of expected to actual displacements of these points with respect to a fixed reference point in the liver. We conclude that, for the rigid livers associated with patients undergoing TIPS, that there is less intraoperative deformation than previously reported by other groups addressing healthy liver deformation, and that the location of an unseen target can be predicted within 3mm accuracy.


Assuntos
Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/cirurgia , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Angiografia/métodos , Inteligência Artificial , Humanos , Reconhecimento Automatizado de Padrão/métodos
5.
J Agric Food Chem ; 54(21): 8244-52, 2006 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-17032035

RESUMO

Understanding how the environment and production and cultivation practices influence the composition and quality of food crops is fundamental to the production of high-quality nutritious foods. In this 3-year study, total phenolics, percent soluble solids, ascorbic acid, and the flavonoid aglycones quercetin, kaempferol, and luteolin were measured in two varieties of tomato (Lycopersicon esculentum L. cv. Ropreco and Burbank) and two varieties of bell peppers (Capsicum annuum L. cv. California Wonder and Excalibur) grown by certified organic and conventional practices in a model system. Significantly higher levels of percent soluble solids (17%), quercetin (30%), kaempferol (17%), and ascorbic acid (26%) were found in Burbank tomatoes (fresh weight basis; FWB), whereas only levels of percent soluble solids (10%) and kaempferol (20%) were significantly higher in organic Ropreco tomatoes (FWB). Year-to-year variability was significant, and high values from 2003 influenced the 3-year average value of quercetin reported for organic Burbank tomatoes. Burbank tomatoes generally had higher levels of quercetin, kaempferol, total phenolics, and ascorbic acid as compared to Ropreco tomatoes. Bell peppers were influenced less by environment and did not display cropping system differences.


Assuntos
Antioxidantes/análise , Capsicum/química , Alimentos Orgânicos/análise , Valor Nutritivo , Controle de Qualidade , Solanum lycopersicum/química , Ácido Ascórbico/análise , Frutas/química , Quempferóis/análise , Quercetina/análise
6.
Artigo em Inglês | MEDLINE | ID: mdl-17354829

RESUMO

We have developed a novel model-to-image registration technique which aligns a 3-dimensional model of vasculature with two semiorthogonal fluoroscopic projections. Our vascular registration method is used to intra-operatively initialize the alignment of a catheter and a preoperative vascular model in the context of image-guided TIPS (Transjugular, Intrahepatic, Portosystemic Shunt formation) surgery. Registration optimization is driven by the intensity information from the projection pairs at sample points along the centerlines of the model. Our algorithm shows speed, accuracy and consistency given clinical data.


Assuntos
Imageamento Tridimensional/métodos , Modelos Biológicos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Técnica de Subtração , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Inteligência Artificial , Simulação por Computador , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/cirurgia , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/cirurgia , Humanos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador
8.
Artigo em Inglês | MEDLINE | ID: mdl-16685965

RESUMO

Accurate 3D/2D vessel registration is complicated by issues of image quality, occlusion, and other problems. This study performs a quantitative comparison of 3D/2D vessel registration in which vessels segmented from preoperative CT or MR are registered with biplane x-ray angiograms by either a) simultaneous two-view registration with advance calculation of the relative pose of the two views, or b) sequential registration with each view. We conclude on the basis of phantom studies that, even in the absence of image errors, simultaneous two-view registration is more accurate than sequential registration. In more complex settings, including clinical conditions, the relative accuracy of simultaneous two-view registration is even greater.


Assuntos
Algoritmos , Angiografia/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Angiografia/instrumentação , Inteligência Artificial , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA