Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Med Brux ; 35(4): 228-32, 2014 Sep.
Artigo em Francês | MEDLINE | ID: mdl-25675624

RESUMO

Muskuloskeletal ultrasound has been incorporated by rheumatologist to the clinical practice over the past decade. The technical improvements of the devices allowed the production of high quality images contributing to better identification of joint inflammation and structural damage. In this review, we highlight the applications of ultrasound in the study of different rheumatic conditions.


Assuntos
Doenças Reumáticas/diagnóstico por imagem , Humanos , Sistema Musculoesquelético/diagnóstico por imagem , Ultrassonografia
2.
Ann Oncol ; 24(2): 350-355, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23038762

RESUMO

BACKGROUND: Aromatase inhibitors (AIs) frequently lead to the AI-induced musculoskeletal syndrome (AIMSS). Looking into its pathophysiology, 6 months of AI therapy thickens the tendon sheath with intra-articular fluid (IAF) retention and loss of grip strength. We here report 24-month follow-up data. PATIENTS AND METHODS: A prospective cohort study of 33 postmenopausal breast cancer patients received adjuvant endocrine therapy; 27 received an AI and 6 received tamoxifen. At baseline, 6 and 24 months patients had a rheumatologic examination, including a grip strength test, and magnetic resonance imaging of both hands and wrists. The primary end point was tenosynovial changes; secondary end points were changes in morning stiffness, grip strength and IAF. RESULTS: Twenty-three AI and 5 tamoxifen patients completed all investigations. Between month 6 and 24, IAF further increased in AI users (P = 0.04) but not in tamoxifen users, and grip strength further decreased in both groups. The worsened tenosynovial changes were strongly correlated with a decrease in grip strength. At 24 months, morning stiffness continued to be present in over a third of AI users. CONCLUSION: AIMSS represents a substantial problem in breast cancer patients. It is associated with tenosynovial changes, IAF retention, joint stiffness and loss of grip strength that do not improve with prolonged use.


Assuntos
Inibidores da Aromatase , Neoplasias da Mama/tratamento farmacológico , Membrana Sinovial/efeitos dos fármacos , Tamoxifeno , Tendões/efeitos dos fármacos , Idoso , Antineoplásicos Hormonais/efeitos adversos , Antineoplásicos Hormonais/farmacologia , Antineoplásicos Hormonais/uso terapêutico , Inibidores da Aromatase/efeitos adversos , Inibidores da Aromatase/farmacologia , Inibidores da Aromatase/uso terapêutico , Quimioterapia Adjuvante/efeitos adversos , Estudos de Coortes , Feminino , Seguimentos , Força da Mão , Humanos , Pessoa de Meia-Idade , Doenças Musculoesqueléticas , Pós-Menopausa , Estudos Prospectivos , Tamoxifeno/efeitos adversos , Tamoxifeno/farmacologia , Tamoxifeno/uso terapêutico
3.
Ann Oncol ; 22(8): 1763-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21273342

RESUMO

BACKGROUND: Our preliminary results showed that tenosynovial changes and decrease in grip strength are associated with the aromatase inhibitor-induced musculoskeletal syndrome (AIMSS). Here, we report the final results and assess the relationship between grip strength and body mass index (BMI). PATIENTS AND METHODS: We conducted a prospective study including postmenopausal early breast cancer patients receiving either an aromatase inhibitor (AI) or tamoxifen. Primary end point was change from baseline in tenosynovial abnormalities. Secondary end points were changes from baseline in morning stiffness, intra-articular fluid and grip strength and its association with BMI. RESULTS: After 6 months of therapy, 74% [95% confidence interval (CI) 51% to 89%] of AI-treated patients had worsened tenosynovial abnormalities, 56% (95% CI 34% to 75%) had increased intra-articular fluid, and 22% (95% CI 9% to 45%) had increased morning stiffness. Grip strength decreased 8% for the left hand (95% CI 2% to 21%) and 11% for the right (95% CI 4% to 17%). Regression analysis suggested that grip strength decreased more for subjects with high or with low BMI. CONCLUSIONS: AIMSS is characterized by tenosynovial changes, intra-articular fluid and morning stiffness. We hypothesize that the quadratic association between BMI and loss of grip strength reflects AI-induced changes on the endocrine control of the growth hormone insulin-like growth factor-I pathway.


Assuntos
Inibidores da Aromatase/efeitos adversos , Índice de Massa Corporal , Neoplasias da Mama/tratamento farmacológico , Força da Mão , Doenças Musculoesqueléticas/induzido quimicamente , Neoplasias Hormônio-Dependentes/tratamento farmacológico , Idoso , Anastrozol , Androstadienos/efeitos adversos , Androstadienos/uso terapêutico , Inibidores da Aromatase/uso terapêutico , Artralgia/induzido quimicamente , Artralgia/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Letrozol , Pessoa de Meia-Idade , Doenças Musculoesqueléticas/fisiopatologia , Nitrilas/efeitos adversos , Nitrilas/uso terapêutico , Pós-Menopausa , Síndrome , Tamoxifeno/efeitos adversos , Tamoxifeno/uso terapêutico , Triazóis/efeitos adversos , Triazóis/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...