Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Acta Cardiol ; 77(4): 322-327, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34218723

RESUMO

BACKGROUND: This study aimed to assess the reliability of pressure derived fractional flow reserve (FFR) measurement and the handling performance of the OptoWire Deux with an optical pressure sensor relative to both the PressureWire X and the Verrata Pressure wire with piezoresistive pressure sensors. METHODS: This single centre study included 80 patients between October 2016 and May 2017 undergoing a diagnostic coronary angiography. The reliability of FFR measurement measured with the OptoWire Deux relative to the PressureWire X and Verrata Pressure wire was assessed by the presence of drift. Drift was defined as a Pd/Pa measurement different from 1.00 ± 0.02 when pulled back after a FFR measurement at the location of the initial equalisation. Handling characteristics for all pressure wires were assessed qualitatively with respect to the PressureWire Aeris. RESULTS: Ninety-eight measurements in 78 patients were performed; two patients were excluded because the lesion could not be crossed. Very stable and reliable FFR measurements with the optical sensors were registered, relative to the piezoresistive pressure sensors. Drift was found in 11%, 37%, and 33% of the measurements for OptoWire Deux, PressureWire X, and Verrata Pressure wire respectively. The handling performance of the OptoWire Deux was better rated for steerability and torqueability in relation to the standard FFR wire. The handling of the PressureWire X was rated equally good whereas the handling of the Verrata pressure wire was rated inferior in relation to the standard FFR wire. CONCLUSIONS: In patients undergoing FFR measurement, the OptoWire Deux has a stable and reliable pressure hence FFR measurement with fewer drift events and has good handling characteristics.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Eur Heart J Acute Cardiovasc Care ; 5(2): 177-84, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25666938

RESUMO

BACKGROUND: High-sensitivity cardiac troponin testing is used to detect myocardial damage in patients with acute chest pain. Heart-type fatty acid binding protein (H-FABP) may be an alternative, available as point-of-care test. METHODS: Patients (n=203) referred by general practitioners for suspected acute coronary syndrome or presenting with typical chest pain and one major cardiovascular risk factor at the emergency department were prospectively included in a single-centre cohort study. High-sensitivity cardiac troponin T (hs-TnT) and point-of-care H-FABP testing were concomitantly performed at admission and after 6h. RESULTS: Maximal hs-TnT levels above the 99th percentile were observed in 152 patients (75%) with 127 (63%) fulfilling criteria for myocardial infarction. Upon admission, hs-TnT and H-FABP were associated with an area under the curve (95% CI) of 0.83 (0.77-0.89) and 0.79 (0.73-0.85), respectively, to predict myocardial infarction, which increased to 0.93 (0.90-0.97) and 0.88 (0.84-0.93), respectively, after 6h. The diagnostic accuracy for non-ST-segment elevation myocardial infarction was somewhat lower with an area under the curve (95% CI) of 0.80 (0.72-0.87), 0.90 (0.84-0.96), 0.73 (0.64-0.81) and 0.77 (0.67-0.86), respectively. When assessment was performed within 3h of chest pain onset, diagnostic accuracy of H-FABP versus hs-TnT was similar. Each standard deviation increase in admission H-FABP was associated with a 68% relative risk increase of all-cause mortality (p-value=0.027) during 666 ± 155 days of follow-up. CONCLUSIONS: Point-of-care H-FABP testing has lower diagnostic accuracy compared with hs-TnT assessment in patients with high pre-test acute coronary syndrome probability, but might be of interest when assessment is possible early after chest pain onset.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/metabolismo , Proteínas de Ligação a Ácido Graxo/metabolismo , Troponina T/metabolismo , Idoso , Área Sob a Curva , Estudos de Coortes , Diagnóstico Precoce , Serviço Hospitalar de Emergência , Proteína 3 Ligante de Ácido Graxo , Proteínas de Ligação a Ácido Graxo/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Troponina T/análise
5.
Eur Heart J ; 24(16): 1473-80, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12919770

RESUMO

BACKGROUND: Electrocardiographic abnormalities and premature ventricular contractions are common in athletes and are generally benign. However, the specific outcome of high-level endurance athletes with frequent and complex ventricular arrhythmias is unclear. Also, information on the predictive accuracy of different investigations in this subgroup is unknown. RESULTS: We report on 46 high-level endurance athletes with ventricular arrhythmias (45 male; median age 31 years) followed-up for a median of 4.7 years. Eighty percent were cyclists. Hypertrophic cardiomyopathy or coronary abnormalities were present in < or =5%. Eighty percent of the arrhythmias had a left bundle branch morphology. Right ventricular (RV) arrhythmogenic involvement (based on a combination of multiple criteria) was manifest in 59% of the athletes, and suggestive in another 30%. Eighteen athletes developed a major arrhythmic event (sudden death in nine, all cyclists). They were significantly younger than those without event (median 23 years vs 38 years; P=0.01). Outcome could not be predicted by presenting symptoms, non-invasive arrhythmia evaluation or morphological findings at baseline. Only the induction of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) during invasive electrophysiological testing was significantly related to outcome (RR 3.4; P=0.02). Focal arrhythmias were associated with a better prognosis than those due to reentry (P=0.02) but the mechanism could be determined in only 22 (48%). CONCLUSIONS: Complex ventricular arrhythmias do not necessarily represent a benign finding in endurance athletes. An electrophysiological study is indicated for risk evaluation, both by defining inducibility and identifying the arrhythmogenic mechanism. Endurance athletes with arrhythmias have a high prevalence of right ventricular structural and/or arrhythmic involvement. Endurance sports seems to be related to the development and/or progression of the underlying arrhythmogenic substrate.


Assuntos
Arritmias Cardíacas/fisiopatologia , Esportes/fisiologia , Adolescente , Adulto , Arritmias Cardíacas/terapia , Ciclismo/fisiologia , Eletrocardiografia Ambulatorial , Eletrofisiologia , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Análise de Sobrevida , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...