1.
Pacing Clin Electrophysiol ; 23(4 Pt 1): 544-51, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10793452

RESUMO

The procedure of lead removal has recently matured into a definable, teachable art with its own specific tools and techniques. It is now time to recognize and formalize the practice of lead removal according to the current methods of medicine and the health care industry. In addition, since at this time the only prospective scientific study of lead extraction is the PLEXES trial, we suggest that studies relating to the techniques of and indications for lead extraction be designed. Recommendations for a common set of definitions, for a framework of training and reviewing physicians in the art, for general methods of reimbursement, and for consistency among clinical trials have been made. Implementation of these recommendations will require additional effort and cooperation from practicing physicians, medical societies, hospital administrations, and industry.


Assuntos
Cateterismo Periférico , Desfibriladores Implantáveis , Marca-Passo Artificial , Falha de Prótese , Procedimentos Cirúrgicos Cardíacos , Cateterismo Periférico/métodos , Cateterismo Periférico/normas , Humanos , Reoperação
2.
Pacing Clin Electrophysiol ; 22(9): 1348-57, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10527016

RESUMO

Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5-year period (1989-1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients was attempted at 226 centers. Indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix or Encore leads (46%), or other causes (2%). Patients were 64+/-17 years of age (range 5-96); 59% were men, 41% women. Leads were implanted 47+/-41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal was achieved for 93% of leads, partial for 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P<0.0001), less experienced physicians (P<0.0001), ventricular leads (P<0.005), noninfected patients (P<0.0005), and younger patients (P<0.0001). Major complications were reported for 1.4% of patients (<1% at centers with >300 cases), minor for 1.7%. Risk of complications increased with number of leads removed (P<0.005) and with less experienced physicians (P<0.005); risk of major complications was higher for women (P<0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.


Assuntos
Remoção de Dispositivo/estatística & dados numéricos , Marca-Passo Artificial/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Falha de Equipamento , Feminino , Humanos , Infecções/etiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Marca-Passo Artificial/estatística & dados numéricos , Fatores de Risco