Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
EuroIntervention ; 19(9): 766-771, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37605804

RESUMO

About one-third of patients undergoing transcatheter aortic valve implantation (TAVI) use oral anticoagulants (OAC), mainly due to atrial fibrillation. General guidelines advise interrupting OAC in patients with a high risk of bleeding undergoing interventions. However, preliminary observational data suggest that the continuation of OAC during TAVI is safe and may reduce the risk of periprocedural thromboembolic events. The Periprocedural Continuation Versus Interruption of Oral Anticoagulant Drugs During Transcatheter Aortic Valve Implantation (POPular PAUSE TAVI) is a multicentre, randomised clinical trial with open-label treatment and blinded endpoint assessment. Patients are randomised 1:1 to periprocedural continuation versus interruption of OAC and are stratified for vitamin K antagonist or direct oral anticoagulant use. The primary endpoint is a composite of cardiovascular mortality, all stroke, myocardial infarction, major vascular complications and type 2-4 bleeding within 30 days after TAVI, according to the Valve Academic Research Consortium-3 criteria. Secondary endpoints include separate individual and composite outcomes, quality of life and cost-effectiveness. Since continuation of OAC is associated with the ancillary benefit that it simplifies periprocedural management, the primary outcome is first analysed for non-inferiority; if non-inferiority is proven, superiority will be tested. Recruitment started in November 2020, and the trial will continue until a total of 858 patients have been included and followed for 90 days. In summary, POPular PAUSE TAVI is the first randomised clinical trial to assess the safety and efficacy of periprocedural continuation versus interruption of OAC in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Qualidade de Vida , Anticoagulantes/uso terapêutico , Hemorragia , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
2.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
4.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
5.
N Engl J Med ; 383(15): 1447-1457, 2020 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-32865376

RESUMO

BACKGROUND: The effect of single as compared with dual antiplatelet treatment on bleeding and thromboembolic events after transcatheter aortic-valve implantation (TAVI) in patients who do not have an indication for long-term anticoagulation has not been well studied. METHODS: In a randomized, controlled trial, we assigned a subgroup of patients who were undergoing TAVI and did not have an indication for long-term anticoagulation, in a 1:1 ratio, to receive aspirin alone or aspirin plus clopidogrel for 3 months. The two primary outcomes were all bleeding (including minor, major, and life-threatening or disabling bleeding) and non-procedure-related bleeding over a period of 12 months. Most bleeding at the TAVI puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2) at 1 year, with both outcomes tested sequentially for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: A total of 331 patients were assigned to receive aspirin alone and 334 were assigned to receive aspirin plus clopidogrel. A bleeding event occurred in 50 patients (15.1%) receiving aspirin alone and in 89 (26.6%) receiving aspirin plus clopidogrel (risk ratio, 0.57; 95% confidence interval [CI], 0.42 to 0.77; P = 0.001). Non-procedure-related bleeding occurred in 50 patients (15.1%) and 83 patients (24.9%), respectively (risk ratio, 0.61; 95% CI, 0.44 to 0.83; P = 0.005). A secondary composite 1 event occurred in 76 patients (23.0%) receiving aspirin alone and in 104 (31.1%) receiving aspirin plus clopidogrel (difference, -8.2 percentage points; 95% CI for noninferiority, -14.9 to -1.5; P<0.001; risk ratio, 0.74; 95% CI for superiority, 0.57 to 0.95; P = 0.04). A secondary composite 2 event occurred in 32 patients (9.7%) and 33 patients (9.9%), respectively (difference, -0.2 percentage points; 95% CI for noninferiority, -4.7 to 4.3; P = 0.004; risk ratio, 0.98; 95% CI for superiority, 0.62 to 1.55; P = 0.93). A total of 44 patients (13.3%) and 32 (9.6%), respectively, received oral anticoagulation during the trial. CONCLUSIONS: Among patients undergoing TAVI who did not have an indication for oral anticoagulation, the incidence of bleeding and the composite of bleeding or thromboembolic events at 1 year were significantly less frequent with aspirin than with aspirin plus clopidogrel administered for 3 months. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Feminino , Hemorragia/epidemiologia , Humanos , Incidência , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Período Pós-Operatório , Trombose/epidemiologia
6.
Am. j. cardiol ; 125(9): 1369-1377, May., 2020. graf.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1099637

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on preBAV was available for 1,262 patients (99.9%). Primary endpoints were pre-discharge moderate-tosevere paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation (PPI), and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n=1,051) or without predilatation (n=211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs. 3.4%, p=0.214; 30-day PPI 9.0% vs. 8.0%, p=0.660; 30-day death or stroke 4.9% vs. 4.4%, p=0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification. (AU)


Assuntos
Substituição da Valva Aórtica Transcateter , Valva Aórtica
7.
N Engl J Med ; 382(18): 1696-1707, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32223116

RESUMO

BACKGROUND: The roles of anticoagulation alone or with an antiplatelet agent after transcatheter aortic-valve implantation (TAVI) have not been well studied. METHODS: We performed a randomized trial of clopidogrel in patients undergoing TAVI who were receiving oral anticoagulation for appropriate indications. Patients were assigned before TAVI in a 1:1 ratio not to receive clopidogrel or to receive clopidogrel for 3 months. The two primary outcomes were all bleeding and non-procedure-related bleeding over a period of 12 months. Procedure-related bleeding was defined as Bleeding Academic Research Consortium type 4 severe bleeding, and therefore most bleeding at the puncture site was counted as non-procedure-related. The two secondary outcomes were a composite of death from cardiovascular causes, non-procedure-related bleeding, stroke, or myocardial infarction at 12 months (secondary composite 1) and a composite of death from cardiovascular causes, ischemic stroke, or myocardial infarction (secondary composite 2), both tested for noninferiority (noninferiority margin, 7.5 percentage points) and superiority. RESULTS: Bleeding occurred in 34 of the 157 patients (21.7%) receiving oral anticoagulation alone and in 54 of the 156 (34.6%) receiving oral anticoagulation plus clopidogrel (risk ratio, 0.63; 95% confidence interval [CI], 0.43 to 0.90; P = 0.01); most bleeding events were at the TAVI access site. Non-procedure-related bleeding occurred in 34 patients (21.7%) and in 53 (34.0%), respectively (risk ratio, 0.64; 95% CI, 0.44 to 0.92; P = 0.02). Most bleeding occurred in the first month and was minor. A secondary composite 1 event occurred in 49 patients (31.2%) receiving oral anticoagulation alone and in 71 (45.5%) receiving oral anticoagulation plus clopidogrel (difference, -14.3 percentage points; 95% CI for noninferiority, -25.0 to -3.6; risk ratio, 0.69; 95% CI for superiority, 0.51 to 0.92). A secondary composite 2 event occurred in 21 patients (13.4%) and in 27 (17.3%), respectively (difference, -3.9 percentage points; 95% CI for noninferiority, -11.9 to 4.0; risk ratio, 0.77; 95% CI for superiority, 0.46 to 1.31). CONCLUSIONS: In patients undergoing TAVI who were receiving oral anticoagulation, the incidence of serious bleeding over a period of 1 month or 1 year was lower with oral anticoagulation alone than with oral anticoagulation plus clopidogrel. (Funded by the Netherlands Organization for Health Research and Development; POPular TAVI EU Clinical Trials Register number, 2013-003125-28; ClinicalTrials.gov number, NCT02247128.).


Assuntos
Anticoagulantes/uso terapêutico , Clopidogrel/uso terapêutico , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Substituição da Valva Aórtica Transcateter , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Hemorragia/epidemiologia , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32098656

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Dilatação/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Período Pré-Operatório , Sistema de Registros , Estudos Retrospectivos
9.
Curr Cardiol Rep ; 21(5): 37, 2019 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-30924027

RESUMO

PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Humanos , Resultado do Tratamento
10.
JACC Cardiovasc Interv ; 12(5): 433-443, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30846081

RESUMO

OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
Int J Cardiol ; 283: 84-87, 2019 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-30449693

RESUMO

Percutaneous recanalization of coronary chronic total occlusions (CTOs) traditionally relies on the use of dual access and large bore catheters, with trans-femoral approach adoption in most of the cases. Aim of this manuscript is to describe an alternative algorithm, that we called "Minimalistic Hybrid Algorithm", in order to minimize the use of double access, large bore catheters, and femoral approach thus reducing patient's discomfort and possibly procedural complications. This algorithm can be interpreted as an evolution of the classic "Hybrid Algorithm" and requires the operator to be confident with all techniques known in this conventional algorithm. Indeed, all possible techniques and approaches of the conventional hybrid approach to treat CTOs are included in a novel diagram for procedural strategy, which offers an alternative sequence of steps to limit, whenever possible, the invasiveness of the procedure. After dividing the cases in "simple" or "complex" CTO lesions according to the available complexity scores and to the "feeling", knowledge and expertise of the operator, a systematic description of the procedural steps is provided. This includes antegrade and retrograde approaches, as well as sub-intimal and intra-luminal techniques, in order to maintain the simpler single-catheter transradial strategies in the first line for the simple CTO, and the adoption of more complex, double access and transfemoral ones in the further steps. The minimalistic hybrid algorithm herein described is a possible alternative sequence of steps in the setting of CTO recanalization, with the potential of limiting the use of double access, large bore catheters, and femoral approach.


Assuntos
Algoritmos , Oclusão Coronária/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Intervenção Coronária Percutânea/métodos , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Artéria Femoral , Humanos , Artéria Radial
12.
Catheter Cardiovasc Interv ; 93(6): 1097-1105, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30461187

RESUMO

OBJECTIVE: The aim of this study was to describe the early use of dedicated patient specific computer modeling in patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve implantation (TAVI), in predicting procedure feasibility and patient related outcome. BACKGROUND: Dedicated patient specific computer modeling, used for optimizing TAVI procedures, is currently validated for the prediction of contact pressure, valve morphology and paravalvular leakage (PVL). The simulation of TAVI procedures is increasingly used in patients with tricuspid aortic valve stenosis. Currently, BAV disease is considered as a relative contra-indication for TAVI due to its specific anatomical characteristics. METHODS: This single center study consisted of seven patients with BAV undergoing TAVI. A patient specific computer simulation was performed based on multislice computer tomography images. The model advised the best fitting prosthetic valve size or sizes and simulated this valve on different implantation depths with the corresponding presence and severity of PVL and prosthetic valve morphology. The simulation results were compared with the procedural outcomes using transesophageal echocardiography (TEE) and fluoroscopy. RESULTS: The patient specific computer modeling predicted accurately the outcome (PVL and valve morphology) of TAVI in all cases. In one case, the TAVI procedure was unsuccessful and retrospectively not suitable for TAVI, which was correctly predicted by the model. CONCLUSION: The patient specific computer modeling adequately predicts feasibility and outcome of TAVI in patients with BAV disease and may extend the applicability of TAVI. Moreover, it improves decision-making and therefore individual procedural outcomes in this difficult patient population.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Técnicas de Apoio para a Decisão , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Desenho de Prótese , Estudos Retrospectivos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
14.
Am J Cardiol ; 121(10): 1239-1245, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29525062

RESUMO

Transcatheter aortic valve implantation (TAVI) is associated with acute kidney injury (AKI), but can also improve the kidney function (IKF). We assessed the effects of kidney function changes in relation to baseline kidney function on 2-year clinical outcomes after TAVI. In total, 639 consecutive patients with aortic stenosis who underwent TAVI were stratified into 3 groups according to the ratio of serum creatinine post- to pre-TAVI: IKF (≤0.80; n = 95 [15%]), stable kidney function (0.80 to 1.5; n = 477 [75%]), and AKI (≥1.5; n = 67 [10%]). Different AKI risk scores were compared using receiving-operator characteristics. Median follow-up was 24 (8 to 44) months. At 3 months, the increase in estimated glomerular filtration rate in the IKF group remained, and the decreased estimated glomerular filtration rate in the AKI group recovered. Compared with a stable kidney function, AKI showed a higher 2-year mortality rate (adjusted hazard ratio [HR] 3.69, 95% confidence interval [CI] 2.43 to 5.62) and IKF a lower mortality rate (adjusted hazard ratio 0.53, 95% CI 0.30 to 0.93). AKI also predicted major and life-threatening bleeding (adjusted odds ratio 2.94, 95% CI 1.27 to 6.78). Independent predictors of AKI were chronic kidney disease and pulmonary hypertension. Independent predictors of IKF were female gender, a preserved kidney function, absence of atrial fibrillation, and hemoglobin level. Established AKI risk scores performed moderately and did not differentiate between AKI and IKF. In conclusion, AKI is transient and is independently associated with a higher mortality rate, whereas IKF is sustained and is associated with a lower mortality rate. These effects are independent of baseline kidney function. Further studies are warranted to investigate the role of IKF and generate a dedicated prediction model.


Assuntos
Estenose da Valva Aórtica/cirurgia , Creatinina/metabolismo , Taxa de Filtração Glomerular , Insuficiência Renal Crônica/metabolismo , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Comorbidade , Feminino , Hemorragia/epidemiologia , Humanos , Hipertensão Pulmonar/epidemiologia , Modelos Lineares , Modelos Logísticos , Masculino , Mortalidade , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Insuficiência Renal Crônica/epidemiologia , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 92(5): E299-E307, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29411523

RESUMO

BACKGROUND: Coronary chronic total occlusions (CTO) usually coexist with diffusely diseased coronary segments proximal and/or distal to the CTO segment. During percutaneous treatment of CTO, multiple overlapping stents are often needed to treat these long lesions. OBJECTIVES: Aim of this study is to report the first use of long, tapered coronary sirolimus-eluting stents (SES) in this setting. METHODS AND RESULTS: This is a retrospective analysis of 100 consecutive patients undergoing CTO recanalization following the hybrid algorithm. Procedural success rate was 89% (11 failures). Among the successful cases, "conventional" drug-eluting stents(DES) were used in 40(44.9%) patients, while in 49(55%) patients long-tapered SES were attempted with a success rate of 98% (1 cross-over to regular stents). Total stent length in the long-tapered DES group was higher compared to the "conventional" stenting group (76 ± 28 mm vs 46 ± 22 mm, P < .001), with a similar total number of stent (1.6 ± 0.8 vs 1.9 ± 0.8). At quantitative coronary analysis, proximal and distal segment involvement was more extended in patients undergoing long-tapered stenting, with longer overall lesion length. No differences in periprocedural complications and clinical outcomes at a mean follow-up of 303 ± 179 days were observed. CONCLUSIONS: The use of long tapered coronary DES is technically feasible and safe for the percutaneous treatment of CTOs, especially for patients presenting with long lesions.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Oclusão Coronária/terapia , Stents Farmacológicos , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
Am J Cardiol ; 120(11): 2035-2040, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29033048

RESUMO

Percutaneous mitral valve repair with the MitraClip is an established treatment for patients with mitral regurgitation (MR) who are inoperable or at high risk for surgery. Atrial Fibrillation (AF) frequently coincides with MR, but only scarce data of the influence of AF on outcome after MitraClip is available. The aim of the current study was to compare the clinical outcome after MitraClip treatment in patients with versus without atrial fibrillation. Between January 2009 and January 2016, all consecutive patients treated with a MitraClip in 5 Dutch centers were included. Outcome measures were survival, symptoms, MR grade, and stroke incidence. In total, 618 patients were treated with a MitraClip. Patients with AF were older, had higher N-terminal B-type natriuretic peptide levels, more tricuspid regurgitation, less often coronary artery disease and a better left ventricular function. Survival of patients treated with the MitraClip was similar for patients with AF (82%) and without AF (non-AF; 85%) after 1 year (p = 0.30), but significantly different after 5-year follow-up (AF 34%; non-AF 47%; p = 0.006). After 1 month, 64% of the patients with AF were in New York Heart Association class I or II, in contrast to 77% of the patients without AF (p = 0.001). The stroke incidence appeared not to be significantly different (AF 1.8%; non-AF 1.0%; p = 0.40). In conclusion, patients with AF had similar 1-year survival, MR reduction, and stroke incidence compared with non-AF patients. However, MitraClip patients with AF had reduced long-term survival and remained more symptomatic compared with those without AF.


Assuntos
Fibrilação Atrial/complicações , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias/epidemiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/mortalidade , Países Baixos/epidemiologia , Desenho de Prótese , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
18.
J Heart Valve Dis ; 26(6): 651-658, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-30207115

RESUMO

BACKGROUND: The MitraClip® system is a percutaneous treatment for mitral regurgitation (MR) that has shown promising results in patients who are inoperable or at high risk for mitral surgery. Data on the efficacy of the system over optimal medical therapy, above all in patients with functional MR, are scarce. The study aim was to assess the effect of MitraClip on the survival of patients with moderate/severe or severe MR compared to medical therapy, using meta-analytical techniques. METHODS: Independently, reviewers searched electronically for relevant articles based on predefined criteria and end-points. Only articles with a comparison between MitraClip and conservative therapy were included. Standard meta-analysis techniques were used. The primary outcomes were 30-day and one-year mortalities. RESULTS: Five observational reports were included that enrolled a total of 1,271 patients: 720 patients underwent percutaneous mitral valve repair (PMVR) with the MitraClip device, and 551 were managed conservatively. A total of 49 all-cause mortality events was reported at 30 days: 3.05% (22/720) in the PMVR arm, and 4.90% (27/510) in the conservative group, with no significant differences in all-cause mortality (OR 0.64; 95% CI 0.36-1.14). A total of 269 all-cause mortality events at one year was reported: 15.14% (109/720) in the PMVR arm, and 29.04% (160/551) in the conservative group. A significant difference favoring PMVR with the MitraClip system over medical therapy alone was observed (OR 0.44; 95% CI 0.30-0.64, p <0.0001). Neither significance between study heterogeneity (p = 0.18) nor publication bias was detected (p = 0.3). CONCLUSIONS: PMVR with the MitraClip system may be associated with an improvement in one-year survival compared to stand-alone medical management.


Assuntos
Procedimentos Endovasculares/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Tratamento Conservador , Humanos , Insuficiência da Valva Mitral/mortalidade
20.
Cardiovasc Diagn Ther ; 6(2): 160-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27054105

RESUMO

Percutaneous edge-to-edge mitral valve (MV) repair is a relatively new treatment option for mitral regurgitation (MR). After the feasibility and safety having been proved in low-surgical-risk patients, the use of this procedure has shifted more to the treatment of high-risk patients. With the absence of randomized controlled trials (RCT) for this particular subgroup, observational studies try to add evidence to the safety aspect of this procedure. These also provide short- and mid-term mortality figures. Several mortality predictors have been identified, which may help the optimal selection of patients who will benefit most from this technique. In this article we provide an overview of the literature about mortality and its predictors in patients treated with the percutaneous edge-to-edge device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...