Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Spectrosc ; 61(7): 671-8, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17697459

RESUMO

Different spatial separations between an illumination ring and a bundle of 50 collection fibers focused to collect light in the center of the ring were used to investigate the recovery of subsurface Raman spectra. The depth of Raman signal recovery and the preservation of spatial information in the recovered signal were investigated using polymer blocks stacked in different geometries. The illumination rings were then combined into a single data set to increase variation in the signal. Multivariate data analysis was used to recover the Raman spectra of the subsurface component. The Raman spectrum of a Delrin target was recoverable at depths up to 22.6 mm of overlying Teflon. Spatial information was lost at approximately 6.5 mm below the Teflon surface. The same protocols were used to recover canine bone spectra transcutaneously at depths up to 5 mm below the skin's surface. The recovered bone spectra were validated by exposed bone measurements.


Assuntos
Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos , Tíbia , Tomografia/instrumentação , Tomografia/métodos , Animais , Cães , Tecnologia de Fibra Óptica/instrumentação , Tecnologia de Fibra Óptica/métodos , Membro Posterior , Análise Multivariada , Fibras Ópticas , Polietileno , Politetrafluoretileno , Resinas Sintéticas
2.
J Biomed Opt ; 11(6): 060502, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17212521

RESUMO

Transcutaneous bone Raman spectroscopy with an exciting annulus of 785-nm laser light surrounding the field of view of a circular array of collection fibers is demonstrated. The configuration provides distributed laser light. The annulus is located 2 to 3 mm beyond the edge of the field of view of the collection fibers to reject contributions from skin and other overlying tissues. Data are presented for rat and chicken tissue. For rat tibia, the carbonate/phosphate ratio measured at a depth of 1 mm below the skin is in error by 2.3% at an integration time of 120 s and within 10% at a 30-s integration time. For chicken tibia 4 mm below the skin surface, the error is less than 8% with a 120-s integration time.


Assuntos
Densidade Óssea , Osso e Ossos/química , Carbonatos/análise , Tecnologia de Fibra Óptica/instrumentação , Iluminação/instrumentação , Fosfatos/análise , Análise Espectral Raman/instrumentação , Animais , Galinhas , Desenho de Equipamento , Análise de Falha de Equipamento , Iluminação/métodos , Fibras Ópticas , Ratos , Ratos Sprague-Dawley , Análise Espectral Raman/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...