Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gait Posture ; 113: 46-52, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38843706

RESUMO

BACKGROUND: A bone-anchored limb (BAL) is an alternative to a traditional socket-type prosthesis for people with transfemoral amputation. Early laboratory-based evidence suggests improvement in joint and limb loading mechanics during walking with a BAL compared to socket prosthesis use. However, changes in cumulative joint and limb loading measures, which may be predictive of degenerative joint disease progression, remain unknown. RESEARCH QUESTION: Do cumulative total limb and hip joint loading during walking change using a BAL for people with unilateral transfemoral amputation, compared to prior socket prosthesis use? METHODS: A case-series cohort of eight participants with prior unilateral transfemoral amputation who underwent BAL hardware implantation surgery were retrospectively analyzed (4 M/4 F; BMI: 27.7 ± 3.1 kg/m2; age: 50.4 ± 10.2 years). Daily step count and whole-body motion capture data were collected before (using socket prosthesis) and one-year after BAL hardware implantation. Cumulative total limb and hip joint loading and between-limb loading symmetry metrics were calculated during overground walking at both time points and compared using Cohen's d effect sizes. RESULTS: One year after BAL hardware implantation, participants demonstrated bilateral increases in cumulative total limb loading (amputated: d = -0.65; intact: d = -0.72) and frontal-plane hip moment (amputated: d = -1.29; intact: d = -1.68). Total limb loading and hip joint loading in all planes remained asymmetric over time, with relative overloading of the intact limb in all variables of interest at the one-year point. SIGNIFICANCE: Despite increases in cumulative total limb and hip joint loading, between-limb loading asymmetries persist. Habitual loading asymmetry has been implicated in contributing to negative long-term joint health and onset or progression of degenerative joint diseases. Improved understanding of methods to address habitual loading asymmetries is needed to optimize rehabilitation and long-term joint health as people with transfemoral amputation increase physical activity when using a BAL.

2.
J Biomech ; 168: 112098, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38636112

RESUMO

Individuals with unilateral transtibial amputation (TTA) using socket prostheses demonstrate asymmetric joint biomechanics during walking, which increases the risk of secondary comorbidities (e.g., low back pain (LBP), osteoarthritis (OA)). Bone-anchored limbs are an alternative to socket prostheses, yet it remains unknown how they influence multi-joint loading. Our objective was to determine the influence of bone-anchored limb use on multi-joint biomechanics during walking. Motion capture data (kinematics, ground reaction forces) were collected during overground walking from ten participants with unilateral TTA prior to (using socket prostheses) and 12-months after bone-anchored limb implantation. Within this year, each participant completed a rehabilitation protocol that guided progression of loading based on patient pain response and optimized biomechanics. Musculoskeletal models were developed at each testing timepoint (baseline or 12-months after implantation) and used to calculate joint kinematics, internal joint moments, and joint reaction forces (JRFs). Analyses were performed during three stance periods on each limb. The between-limb normalized symmetry index (NSI) was calculated for joint moments and JRF impulses. Discrete (range of motion (ROM), impulse NSI) dependent variables were compared before and after implantation using paired t-tests with Bonferroni-Holm corrections while continuous (ensemble averages of kinematics, moments, JRFs) were compared using statistical parametric mapping (p < 0.05). When using a bone-anchored limb, frontal plane pelvic (residual: pre = 9.6 ± 3.3°, post = 6.3 ± 2.5°, p = 0.004; intact: pre = 10.2 ± 3.9°, post = 7.9 ± 2.6°, p = 0.006) and lumbar (residual: pre = 15.9 ± 7.0°, post = 10.6 ± 2.5°, p = 0.024, intact: pre = 17.1 ± 7.0°, post = 11.4 ± 2.8°, p = 0.014) ROM was reduced compared to socket prosthesis use. The intact limb hip extension moment impulse increased (pre = -11.0 ± 3.6 Nm*s/kg, post = -16.5 ± 4.4 Nm*s/kg, p = 0.005) and sagittal plane hip moment impulse symmetry improved (flexion: pre = 23.1 ± 16.0 %, post = -3.9 ± 19.5 %, p = 0.004, extension: pre = 29.2 ± 20.3 %, post = 8.7 ± 22.9 %, p = 0.049). Residual limb knee extension moment impulse decreased compared to baseline (pre = 15.7 ± 10.8 Nm*s/kg, post = 7.8 ± 3.9 Nm*s/kg, p = 0.030). These results indicate that bone-anchored limb implantation alters multi-joint biomechanics, which may impact LBP or OA risk factors in the TTA population longitudinally.


Assuntos
Tíbia , Caminhada , Humanos , Masculino , Caminhada/fisiologia , Fenômenos Biomecânicos , Feminino , Pessoa de Meia-Idade , Tíbia/cirurgia , Tíbia/fisiologia , Adulto , Amplitude de Movimento Articular , Membros Artificiais , Prótese Ancorada no Osso , Amputação Cirúrgica/reabilitação , Idoso , Articulação do Joelho/fisiologia , Articulação do Joelho/fisiopatologia , Articulação do Quadril/fisiologia , Articulação do Quadril/cirurgia
3.
J Biomech ; 155: 111658, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37276681

RESUMO

People with unilateral transfemoral amputation using socket prostheses are at increased risk for developing osteoarthritis in both the residual hip and intact lower-limb joints. Osseointegrated prostheses are a surgical alternative to socket prostheses that directly attach to the residual femur via a bone-anchored implant, however their multi-joint loading effect is largely unknown. Our objective was to establish how osseointegrated prostheses influence joint loading during walking. Motion capture data (kinematics, ground reaction forces) were collected from 12 participants at baseline, with socket prostheses, and 12-months after prosthesis osseointegration during overground walking at self-selected speeds. Subject-specific musculoskeletal models were developed at each timepoint relative to osseointegration. Internal joint moments were calculated using inverse dynamics, muscle and joint reaction forces (JRFs) were estimated with static optimization. Changes in internal joint moments, JRFs, and joint loading-symmetry were compared using statistical parametric mapping (p≤ 0.05) before and after osseointegration. Amputated limb hip flexion moments and anterior JRFs decreased during terminal stance (p = 0.002, <0.001; respectively), while amputated limb hip abduction moments increased during mid-stance (p < 0.001), amputated hip rotation moment changed from internal to external throughout early stance (p < 0.001). Intact limb hip extension and knee flexion moments (p = 0.028, 0.032; respectively), superior and resultant knee JRFs (p = 0.046, 0.049; respectively) decreased during the loading response following prosthesis osseointegration. These results may indicate that the direct loading transmission of these novel prostheses create a more typical mechanical environment in bilateral joints, which is comparable with loading observed in able-bodied individuals and could decrease the risk of development or progression of osteoarthritis.


Assuntos
Membros Artificiais , Osseointegração , Humanos , Caminhada/fisiologia , Implantação de Prótese/métodos , Amputação Cirúrgica , Membros Artificiais/efeitos adversos , Fenômenos Biomecânicos , Marcha/fisiologia
4.
Clin Biomech (Bristol, Avon) ; 98: 105715, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35839740

RESUMO

BACKGROUND: Patients with transfemoral amputation and socket prostheses are at a heightened risk of developing musculoskeletal overuse injuries, commonly due to altered joint biomechanics. Osseointegrated prostheses, which involve direct anchorage of the prosthesis to the residual limb through a bone anchored prosthesis, are a novel alternative to sockets yet their biomechanical effect is largely unknown. METHODS: Four patients scheduled to undergo unilateral transfemoral prosthesis osseointegration completed two data collections (baseline with socket prosthesis and 12-months after prosthesis osseointegration) in which whole-body kinematics and ground reaction forces were collected during stand-to-sit tasks. Trunk, pelvis, and hip kinematics, and the surrounding muscle forces, were calculated using subject-specific musculoskeletal models developed in OpenSim. Peak joint angles and muscle forces were compared between timepoints using Cohen's d effect sizes. FINDINGS: Compared to baseline with socket prostheses, patients with osseointegrated prostheses demonstrated reduced lateral trunk bending (d = 1.46), pelvic obliquity (d = 1.09), and rotation (d = 1.77) toward the amputated limb during the stand to sit task. This was accompanied by increased amputated limb hip flexor, abductor, and rotator muscle forces (d> > 0.8). INTERPRETATION: Improved lumbopelvic movement patterns and stabilizing muscle forces when using an osseointegrated prosthesis indicate that this novel prosthesis type likely reduces the risk of the development and/or progression of overuse injuries, such as low back pain and osteoarthritis. We attribute the increased muscle hip muscle forces to the increased load transmission between the osseointegrated prosthesis and residual limb, which allows a greater eccentric ability of the amputated limb to control lowering during the stand-to-sit task.


Assuntos
Amputados , Membros Artificiais , Transtornos Traumáticos Cumulativos , Amputação Cirúrgica , Fenômenos Biomecânicos , Transtornos Traumáticos Cumulativos/etiologia , Humanos , Osseointegração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...