Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 124(9): 093901, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32202875

RESUMO

Submicron-thick hexagonal boron nitride crystals embedded in noble metals form planar Fabry-Perot half-microcavities. Depositing Au nanoparticles on top of these microcavities forms previously unidentified angle- and polarization-sensitive nanoresonator modes that are tightly laterally confined by the nanoparticle. Comparing dark-field scattering with reflection spectroscopies shows plasmonic and Fabry-Perot-like enhancements magnify subtle interference contributions, which lead to unexpected redshifts in the dark-field spectra, explained by the presence of these new modes.

2.
Sci Rep ; 6: 29818, 2016 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-27436496

RESUMO

This paper presents the investigation of path loss variation for subject-specific on-body radio propagation channels, considering the effect of metallic spectacles and loop like metallic accessories. Adding metallic items may affect the operability of Body Centric Wireless Communications (BCWC). Measurements were carried out in an RF-shielded room lined with microwave absorbing sheets for strategically placed bodyworn antennas covering the upper front torso and the lower limbs. The path loss of the on-body radio channel was characterized explicitly taking into account the body size of the subjects. For metallic loop-like accessories, the results indicate that for underweight subjects, there was a slightly higher influence, up to 2%, compared to normal and overweight subjects. Our findings indicate that a noticeable effect exists on on-body channels for dynamic movements where the metallic watch acts as a local scatterer that affects the non-line-of-sight (NLOS) signal path between transmitter and receiver for underweight subjects in comparison to normal and overweight subjects. The path loss decreases when the receiving terminal was positioned very close to the metallic item. If a loop-like metallic accessory is not appropriately considered when designing the radio channel on a subject, the reliability of the body-centric wireless system may degrade.

3.
Adv Mater ; 26(24): 4074-81, 2014 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-24740481

RESUMO

Circularly polarized light is incident on a nanostructured chiral meta-surface. In the nanostructured unit cells whose chirality matches that of light, superchiral light is forming and strong optical second harmonic generation can be observed.

4.
Opt Express ; 21(13): 15464-74, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23842334

RESUMO

We have studied both theoretically and experimentally symmetric and asymmetric planar metallic Split Ring Resonators. We demonstrate that introducing structural asymmetry makes it possible to excite several higher order modes of both even (l = 2) and odd (l = 3, 5) order, which are otherwise inaccessible for a normally incident plane wave in symmetric structures. Experimentally we observe that the even mode resonances of asymmetric resonators have a quality factor 5.8 times higher than the higher order odd resonances.

6.
Opt Express ; 20(1): 256-64, 2012 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-22274348

RESUMO

While it has been demonstrated that, above its resolution limit, Second Harmonic Generation (SHG) microscopy can map chiral local field enhancements, below that limit, structural defects were found to play a major role. Here we show that, even below the resolution limit, the contributions from chiral local field enhancements to the SHG signal can dominate over those by structural defects. We report highly homogeneous SHG micrographs of star-shaped gold nanostructures, where the SHG circular dichroism effect is clearly visible from virtually every single nanostructure. Most likely, size and geometry determine the dominant contributions to the SHG signal in nanostructured systems.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Phys Rev Lett ; 106(22): 226803, 2011 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-21702624

RESUMO

In high definition mapping of the plasmonic patterns on the surfaces of nanostructures, the diffraction limit of light remains an important obstacle. Here we demonstrate that this diffraction limit can be completely circumvented. We show that upon illuminating nanostructures made of nickel and palladium, the resulting surface-plasmon pattern is imprinted on the structures themselves; the hotspots (regions of local field enhancement) are decorated with overgrowths, allowing for their subsequent imaging with scanning-probe techniques. The resulting resolution of plasmon pattern imaging is correspondingly improved.

8.
Phys Rev Lett ; 104(12): 127401, 2010 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-20366565

RESUMO

We present a new electromagnetic phenomenon-the asymmetric second-harmonic generation from planar chiral structures. The effect consists in distinguishing the handedness of a chiral material by rotating the sample in an experiment involving solely linearly polarized light. This phenomenon originates in the surface plasmon resonance of chiral gold nanostructures, where homodyne interference of anisotropic and chiral electric and/or magnetic multipoles appears to play an important role.

9.
Urol Radiol ; 10(3): 144-50, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-3206742

RESUMO

Vascular problems represent the most frequent cause of organic impotence. Abnormal venous drainage from the corpora cavernosa is now widely accepted as the major cause of vasculogenic impotence. Based on our experience with more than 450 radiologic procedures, we describe the technique of cavernosography and cavernosometry, the effect of papaverine injection, and we review the literature.


Assuntos
Disfunção Erétil/diagnóstico por imagem , Pênis/diagnóstico por imagem , Disfunção Erétil/patologia , Humanos , Masculino , Métodos , Papaverina/farmacologia , Ereção Peniana/efeitos dos fármacos , Pênis/irrigação sanguínea , Pênis/patologia , Flebografia , Veias/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...