Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 69(12): 1911-4, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21497100

RESUMO

Gamma and fast neutron dose spatial distributions have been measured at the collimator exit of the epithermal neutron beam of LVR-15 reactor (Rez). Measurements were performed by means of optically analyzed Fricke-gel-layer detectors. The separation of the two dose contributions has been achieved by suitable pixel-to-pixel elaboration of the light transmittance images of Fricke-gel-layer detectors prepared with water and heavy water.

2.
Appl Radiat Isot ; 68(4-5): 772-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19879155

RESUMO

Normoxic polymer gel dosimeters are studied, with the aim of achieving a valid and advantageous method for in-phantom 3D dose determinations. Developments were carried out in the application of such dosimetric material to the method based on dosimeter gel layers that has shown good reliability for absorbed dose imaging in radiotherapy. The technique has been improved, in particular taking care of minimizing the oxygen infiltration into the gel matrix in order to suitably avoid its effect of inhibiting the polymerization process after exposure. A suitable choice of the material of dosimeter walls has brought to achieve good steadiness in time of dosimeter sensitivity and satisfactory results in dose imaging and depth-dose profiling.


Assuntos
Acrilamidas/química , Acrilamidas/efeitos da radiação , Radiometria/métodos , Radioterapia Conformacional/métodos , Géis/química , Géis/efeitos da radiação , Teste de Materiais , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Appl Radiat Isot ; 67(7-8 Suppl): S214-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19376722

RESUMO

A thorax phantom has been designed, consisting of PMMA and PE plates containing a cavity filled with a laboratory-made lung-substitute. Fricke-gel dosimeters have been placed in the lung-substitute volume, and the phantom has been irradiated at the epithermal column of LVR-15 reactor. Absorbed dose images have been obtained for both gamma radiation and charged particles emitted in the (10)B reactions with thermal neutrons. Measurements with thermoluminescence dosimeters (TLDs) and Monte Carlo (MC) calculations have been performed too, in order to attain inter-comparison of results.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Nêutrons Rápidos/uso terapêutico , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Boro/uso terapêutico , República Tcheca , Géis , Humanos , Isótopos/uso terapêutico , Reatores Nucleares , Fótons/uso terapêutico , Radiossensibilizantes/uso terapêutico , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Tórax
4.
Appl Radiat Isot ; 67(7-8 Suppl): S195-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19375935

RESUMO

Gel dosimeters in form of layers have shown noticeable potentiality for in-phantom dose profiling and imaging in BNCT neutron fields. Such dosimeters give the possibility of achieving spatial dose distributions of each dose contribution in neutron fields. The various dose components are separated by means of pixel-to-pixel manipulations of pairs of images acquired with gel dosimeters having different isotopic compositions. The reliability of polymer-gel-layer dosimeters (PGLD) for BNCT has been studied and their utilisation limits have been inspected.


Assuntos
Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Imagens de Fantasmas/estatística & dados numéricos , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Resinas Acrílicas , Géis , Humanos , Itália , Neoplasias/radioterapia
5.
Radiat Prot Dosimetry ; 126(1-4): 604-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17496302

RESUMO

A thorough evaluation of the dose inside a specially designed and built facility for extra-corporeal treatment of liver cancer by boron neutron capture therapy (BNCT) at the High Flux Reactor (HFR) Petten (The Netherlands) is the necessary step before animal studies can start. The absorbed doses are measured by means of gel dosemeters, which help to validate the Monte Carlo simulations of the spheroidal liver holder that will contain the human liver for irradiation with an epithermal neutron beam. These dosemeters allow imaging of the dose due to gammas and to the charged particles produced by the (10)B reaction. The thermal neutron flux is extrapolated from the boron dose images and compared to that obtained by the calculations. As an additional reference, Au, Cu and Mn foil measurements are performed. All results appear consistent with the calculations and confirm that the BNCT liver facility is able to provide an almost homogeneous thermal neutron distribution in the liver, which is a requirement for a successful treatment of liver metastases.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Géis/efeitos da radiação , Neoplasias Hepáticas/radioterapia , Nêutrons , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Terapia por Captura de Nêutron de Boro/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Itália , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...