Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Nucl Med Commun ; 24(3): 241-9, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12612464

RESUMO

In today's cost containment environment it is important to consider changes to standard protocols which would reduce cost, particularly if there is no significant loss of diagnostic accuracy. The aim of the present study was to assess the usefulness of a gated stress-only Tc sestamibi protocol in comparison to conventional gated dual isotope rest-stress myocardial perfusion single photon emission computed tomography (SPECT) in the detection and localization of coronary artery disease (CAD). Sixty-five consecutive patients (65+/-10 years, 22 women) who had undergone conventional gated perfusion SPECT were chosen retrospectively. Fifty-three of these 65 patients had previous coronary arteriography, 45 with at least one stenosis, eight without stenosis, and 12 of these 65 patients had <5% likelihood of CAD. Three readers interpreted the gated stress-only and dual isotope studies in separate sessions blinded to (1). their previous readings, (2). the interpretation by others, and (3). the angiographic results. Readers used a five-point scale to score their visual and quantitative assessment of perfusion, function and compromised vascular territory. Their average score was used for determination of the accuracy by using receiver operating characteristic (ROC) analysis of the techniques. The areas under ROC curves were determined for the detection of CAD and localization of vascular territories. Fifty-four of these patients had 97 significant stress induced perfusion defects as determined by the CEqual quantitative program. The agreement between protocols for the assessment of reversibility in these 97 defects was analysed. There were no statistically significant differences between dual isotope rest/stress and gated stress-only studies for the detection and localization of CAD. The area under the dual isotope rest/stress ROC curve was 0.78+/-0.07 compared to the area under the gated stress-only ROC curve of 0.80+/-0.06, resulting in P=0.30. For the combined vessels comparison of the area under the dual isotope rest/stress ROC curve was 0.73+/-0.04 versus the area under the gated stress-only ROC curve of 0.74+/-0.04, resulting in P=0.27. Similar non-significant differences were obtained when comparing the area under the dual isotope versus gated stress-only ROC curves for the left anterior descending vascular territory (LAD, 0.61+/-0.08 vs 0.660.08, P=0.14), the left circumflex vascular territory (LCX, 0.82+/-0.07 vs 0.81+/-0.06, P =0.47) or the right coronary vascular territory (RCA, 0.80+/-0.06 vs 0.78+/-0.06, P=0.28). The analysis of the reversibility of stress induced perfusion defects yielded a global agreement between protocols of 93% (kappa=0.42). The differences were due to the expert readers, using the gated stress-only protocol, misinterpreting some patients with attenuation artefacts, subendocardial infarction and functional stunning. These results show that the lower cost gated stress-only myocardial Tc myocardial perfusion SPECT studies are comparable to the conventional dual isotope studies when the clinical question is the detection and localization of coronary artery disease. Nevertheless, we also showed that this approach is limited when attempting to interpret the reversibility of stress induced perfusion defects in patients who exhibit attenuation artefacts, subendocardial infarction and functional stunning.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Teste de Esforço , Imagem do Acúmulo Cardíaco de Comporta/métodos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
2.
J Nucl Cardiol ; 8(6): 645-51, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11725260

RESUMO

BACKGROUND: Two methods of computing left ventricular volumes and ejection fraction (EF) from 8-frame gated perfusion single photon emission computed tomography (SPECT) were compared with each other and with magnetic resonance (MR) imaging. METHODS AND RESULTS: Thirty-five subjects underwent 8-frame gated dual-isotope SPECT imaging and 12- to 16-frame gated MR imaging. Endocardial boundaries on short-axis MR images were hand traced by experts blinded to any SPECT results. Volumes and EF were computed with the use of Simpson's rule. SPECT images were analyzed for the same functional variables with the use of 2 automatic programs, Quantitative Gated SPECT (QGS) and the Emory Cardiac Toolbox (ECTb). The mean difference between MR and SPECT EF was 0.008 for ECTb and 0.08 for QGS. QGS showed a slight trend toward higher correlation for EF (r = 0.72, SE of the estimate = 0.08) than ECTb (r = 0.70, SE of the estimate = 0.09). For both SPECT methods, left ventricular volumes were similarly correlated with MR, although SPECT volumes were higher than MR values by approximately 30%. CONCLUSIONS: QGS and ECTb values of cardiac function computed from 8-frame gated perfusion SPECT correlate very well with each other and correlate well with MR. Averaged over all subjects, ECTb measurements of EF are not significantly different from MR values but QGS significantly underestimates the MR values.


Assuntos
Volume Cardíaco/fisiologia , Imageamento por Ressonância Magnética , Volume Sistólico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Disfunção Ventricular Esquerda/fisiopatologia
3.
J Nucl Med ; 41(12): 1941-6, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11138676

RESUMO

UNLABELLED: The objective of this study was to compare visual assessment of 3-dimensional color-modulated (to counts) surface displays with visual assessment of oblique tomographic slices of myocardial SPECT perfusion distributions in the detection and localization of coronary artery disease (CAD). METHODS: Sixty-two consecutive patients (41 men, 21 women; mean age, 61 +/- 11 y) who had undergone conventional dual-isotope perfusion SPECT were retrospectively chosen; 50 had undergone coronary arteriography previously, and 12 had less than a 5% likelihood of CAD. Four readers interpreted the 3-dimensional displays and slices in separate sessions while unaware of the findings of previous readings, the interpretations of others, and the angiographic results. The readers used a 5-point scoring system. Their average score was used for receiver operating characteristic (ROC) analysis. The area under the ROC curves was determined so that the ability of the 2 methods to detect and localize CAD could be compared. RESULTS: No significant differences were found between visual interpretation of 3-dimensional displays and visual interpretation of slices. CONCLUSION: These preliminary results indicate that visual interpretation of 3-dimensional displays of myocardial perfusion SPECT distributions may someday replace visual assessment of conventional slices without loss of diagnostic accuracy.


Assuntos
Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada de Emissão de Fóton Único , Área Sob a Curva , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
4.
Am J Cardiol ; 84(12): 1369-74, 1999 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-10606106

RESUMO

The aim of this study was to investigate the relation between reversible thallium single-photon emission computed tomography (SPECT) myocardial perfusion defects at 1-year after revascularization and quantitative indexes in Emory Angioplasty versus Surgery Trial (EAST) and outcomes 3 years after revascularization in 336 patients. EAST was a randomized controlled trial assessing cardiac outcomes for angioplasty versus bypass surgery for patients with multivessel coronary artery disease. During this prospective trial, a substudy included the evaluation of the prognostic value of reversible defects on quantitative thallium SPECT. At 1-year after revascularization, 336 patients underwent SPECT thallium-201 stress myocardial perfusion and 3-hour delayed imaging. Subsequent events, percutaneous transluminal coronary angioplasty, coronary artery bypass graft surgery, myocardial infarction, and death, were recorded at 3 years. A stress-induced reversible thallium-201 defect was defined using a quantitative index of a reversibility score >30% and severity score >500. Reversible defects were observed more frequently in the percutaneous transluminal coronary angioplasty than in the coronary artery bypass graft surgery treatment groups (46% vs 27%, p <0.001). A total of 123 patients had stress-induced, reversible thallium defects and more events than patients with other perfusion results (freedom from all events was 81.3% vs 94% [p <0.001], and freedom from myocardial infarction and death 88.3% vs 95.5% [p = 0.031]). Quantitative thallium SPECT at 1 year after revascularization risk stratifies patients as to their likelihood of major cardiac outcomes.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Causas de Morte , Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Teste de Esforço , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/mortalidade , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Complicações Pós-Operatórias/mortalidade , Prognóstico , Taxa de Sobrevida , Radioisótopos de Tálio
5.
J Nucl Med ; 40(4): 650-9, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10210225

RESUMO

UNLABELLED: A new technique for computing left ventricular function, including left ventricular volumes, mass and ejection fraction, has been developed. This method is a logical extension of the results of a standard perfusion quantification technique; thus, it allows integration of perfusion and functional information. METHODS: Anatomically based models of the endocardial and epicardial surfaces are generated using the myocardial samples for which perfusion values are quantified, for all frames in the cardiac cycle. With these surface points, left ventricular chamber volume and myocardial volume can be computed. A computer simulation was used to determine the sensitivity of the approach to the assumptions of the model. Validation of volume, mass and ejection fraction was performed with correlative MR studies, and ejection fraction and left ventricular volumes were further investigated using correlative first-pass studies. RESULTS: Automated processing was successful in 96% of the cases analyzed. End diastolic volume, end systolic volume, left ventricular mass and left ventricular ejection fraction correlated with MRI with r = 0.97, 0.99, 0.87, and 0.85, respectively. Ejection fraction from tomography correlated with first-pass values with r = 0.82, and end diastolic and end systolic volumes from tomography correlated with first-pass values with r = 0.85 and r = 0.91, respectively. CONCLUSION: The new integrated approach is accurate and robust for computing both perfusion and function from perfusion tomograms.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Infarto do Miocárdio/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Compostos Radiofarmacêuticos
7.
J Nucl Cardiol ; 4(2 Pt 1): 108-16, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9115062

RESUMO

BACKGROUND: Two-dimensional polar maps have been validated previously with coronary arteriography for determining vascular involvement of defects from a patient's myocardial perfusion distributions with and without quantification. The purpose of this study was to validate previously developed three-dimensional color-modulated surface displays representing myocardial perfusion. METHODS AND RESULTS: The validation consisted of comparing the agreement between the three-dimensional displays and two-dimensional polar maps in localizing perfusion defects to vascular territories in 30 patients (16 men/14 women) who underwent both a 1-day rest/stress exercise 99mTc-labeled sestamibi study and coronary arteriography. Reading by two experts was used to identify the size and location of quantified defects and corresponding areas of reversibility seen in the polar maps and, on a separate day, in the three-dimensional displays. Agreement between the two-dimensional polar maps and the three-dimensional displays resulted in identical percentages for the localization of both defects and reversibilities: left anterior descending coronary artery, 87% (26/30); left circumflex coronary artery, 97% (29/30); right coronary artery, 97% (29/30); and coronary artery disease, 97% (29/30). CONCLUSIONS: These results show that the color-modulated three-dimensional displays are at least as good as the CEqual polar maps in localizing a perfusion defect and its reversibility to angiographically defined vascular territories and thus could be used in the routine clinical evaluation of myocardial perfusion.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Angiografia Coronária , Doença das Coronárias/epidemiologia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos
8.
Semin Nucl Med ; 27(1): 55-67, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9122724

RESUMO

There is a resurgence of interest in lymphoscintigraphy because of attention to the sentinel node concept and the availability of the surgical gamma probe that can be used in the operating room to localize radiolabeled sentinel nodes. Conventional surgical management of melanoma has been altered for intermediate thickness tumors such that lymph node dissection is performed for a lymph node bed only if the sentinel node is tumor positive on histological exam after gamma probe-guided excision. This approach is cost effective, saving about 80% of these patients (sentinel node tumor negative) the cost and morbidity of unnecessary "elective lymph node dissection." In addition, a biopsy can be performed on all lymph node beds that receive lymphatic drainage from the tumor site thereby improving staging and perhaps survival by providing the most appropriate therapy. Substantial work has been done to develop optimum imaging techniques and the best radiopharmaceutical preparation to achieve accurate, reproducible lymphatic drainage images. Our methodology includes the following intradermal injections of a technetium 99m sulfur colloid (modified preparation) are followed by dynamic imaging (10 seconds per frame); static imaging up to 30 minutes and late imaging at 1 to 2 hours. Images show lymphatic channels that lead to sentinel nodes in 1, 2, 3, or more anatomic locations. Surgical management is altered to include sampling sentinel nodes of nodal beds, many of which would not have been sampled by previous conventional surgical estimates of lymphatic drainage. While clinical success of lymphoscintigraphy and intraoperative probe localization of the sentinel node in melanoma is evident, use of lymphoscintigraphy and the sentinel node concept in breast cancer is investigative, but promising. The radiopharmaceutical is injected around the tumor in the breast followed by imaging to delineate lymphatic drainage to the sentinel node(s). Optimum methodologies for radiopharmaceutical, volume and/or activity of injectate, and imaging have yet to be determined. Breast lymphatic drainage can be to axilla, internal mammary, and/or supraclavicular nodes in any combination.


Assuntos
Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Melanoma/secundário , Neoplasias Cutâneas/patologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Cuidados Intraoperatórios , Metástase Linfática , Masculino , Melanoma/cirurgia , Estadiamento de Neoplasias , Cintilografia/instrumentação , Compostos Radiofarmacêuticos , Neoplasias Cutâneas/cirurgia , Coloide de Enxofre Marcado com Tecnécio Tc 99m
9.
J Nucl Med ; 37(9): 1575-8, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8790222

RESUMO

UNLABELLED: There has been a resurgence in the use of lymphoscintigraphy for the external detection of lymph nodes for metastatic melanoma and breast tumors. Technetium-99m-antimony trisulfide colloid was the radiopharmaceutical developed for this procedure and was found to have a narrow distribution of small particles, 0.003-0.03 microns, but it was never approved by the FDA. Technetium-99m-sulfur colloid also forms particles and this article reports on the effects different preparation parameters have on its particle size distribution and stability. METHODS: Four groups of kits were evaluated, kits which utilized: (a) a reduced heating protocol with a new 99mTc-elution, (b) a reduced heating protocol with an old 99mTc-elution, (c) a prolonged heating protocol with a new 99mTc-elution and (d) a prolonged heating protocol with an old 99mTc-elution. The particle size distribution and the stability of the different 99mTc-sulfur colloid kit preparations were evaluated over 6 hr utilizing polycarbonate filters ranging from 0.03 to 10 microns. RESULTS: In vitro studies demonstrated no significant change in the particle size distribution over a 6-hr period and all 99mTc-sulfur colloid preparations had a bimodal particle size distribution pattern. Importantly, heating the kit for shorter periods of times utilizing [99mTc]pertechnetate, which had a longer ingrowth of [99mTc]pertechnetate, produced a formulation which had the largest percentage of particles smaller than 0.03 microns. CONCLUSION: In our clinical setting, 99mTc-sulfur colloid prepared with the reduced heating protocol and utilizing [99mTc]pertechnetate, which has the highest ingrowth of [99mTc]pertechnetate has proved to be an excellent agent for lymphoscintigraphy studies. This preparation has demonstrated rapid movement of the particles from the primary site to the lymph nodes in over 97% (106/109) of the patients we have studied.


Assuntos
Linfonodos/diagnóstico por imagem , Kit de Reagentes para Diagnóstico , Coloide de Enxofre Marcado com Tecnécio Tc 99m , Humanos , Tamanho da Partícula , Cintilografia , Coloide de Enxofre Marcado com Tecnécio Tc 99m/síntese química , Coloide de Enxofre Marcado com Tecnécio Tc 99m/farmacocinética , Fatores de Tempo , Distribuição Tecidual
10.
Radiology ; 199(1): 171-5, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8633142

RESUMO

PURPOSE: To assess the influence of lymphoscintigraphic and intraoperative gamma probe findings on the surgical management of melanoma and to test reproducibility of lymphoscintigraphic findings. MATERIALS AND METHODS: After lymphoscintigraphic identification of the sentinel node, intraoperative gamma probe localization and sentinel lymph node excision were performed in 25 patients. To assess reproducibility, 13 patients underwent lymphoscintigraphy twice within 2-17 days. A modified preparation of technetium-99m sulfur colloid with smaller particles than routinely obtained was injected intradermally around the lesion. Dynamic flow images were obtained at 10 seconds per frame followed by a series of static images obtained every 5 minutes for 30 minutes. RESULTS: A sentinel node was identified in all patients. In eight patients, multiple drainage pathways were seen and surgical management was changed. In 11 of the 13 who underwent lymphoscintigraphy twice, sentinel node identification was reproducible. CONCLUSION: Lymphoscintigraphy is reproducible in detection of the sentinel node and with the surgical probe helps effectively guide surgical management.


Assuntos
Linfonodos/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Melanoma/secundário , Neoplasias Cutâneas/diagnóstico por imagem , Feminino , Humanos , Cuidados Intraoperatórios , Excisão de Linfonodo , Metástase Linfática , Masculino , Melanoma/cirurgia , Pessoa de Meia-Idade , Cintilografia , Reprodutibilidade dos Testes , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/cirurgia , Coloide de Enxofre Marcado com Tecnécio Tc 99m
11.
J Nucl Med ; 36(4): 697-703, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7699467

RESUMO

UNLABELLED: Two methods for generating left ventricular epicardial surface from SPECT perfusion tomograms are described and validated. Both methods use the locations of the maximal reconstructed count values determined from a perfusion quantification procedure as a basis for generating surfaces. METHODS: The first method fits circular contours, which are perpendicular to the long-axis, to the points obtained from perfusion quantification. The second method applies median and linear filters to the points to remove noise but maintain the basic shape of the surface. Both models are validated against an automatic technique and against the user-traced surfaces of both the perfusion image and an MR image of the same patient. RESULTS: The median-filtered model was found to be closer to the standard surfaces than the circular model in all cases, and 85% of the points on the median-filtered surfaces were within one SPECT pixel length of the hand-traced MR surfaces. CONCLUSION: Accurate, three-dimensional left ventricular epicardial surfaces can be generated quickly and easily from already existing perfusion quantification software. The resulting images may be useful for realistic displays of ventricular size, shape and the three-dimensional distribution of perfusion.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Circulação Coronária/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Modelos Cardiovasculares , Isquemia Miocárdica/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi
12.
J Nucl Med ; 35(8): 1237-44, 1994 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8046474

RESUMO

UNLABELLED: A detailed analysis of intrapatient reproducibility of exercise SPECT thallium studies is presented. METHODS: Twenty patients in stable condition were re-examined with exercise-redistribution SPECT201 Tl within 3-9 days without intervening procedures. At peak stress, 3.5 mCi 201Tl were given intravenously 1 min prior to exercise termination. SPECT imaging started at 5 and 180 min. Acquisition and processing protocols were the same for all studies. Coronary angiography was performed on 19 patients and showed coronary artery disease (CAD) in 18, and no CAD in one; one patient did not have coronary arteriography. RESULTS: For 16 of 20 patients, exercise levels and ECG were comparable for both studies. Ten patients reproduced ST-segment depression; two reproduced angina; one had left bundle branch block (LBBB) on both studies after 1 min of exercise. The remaining seven patients had no ECG changes or symptoms during exercise. Four of 20 (20%) thallium scans differed: three in degree of redistribution and one (5%) in presence of a second stress defect. In three of four patients whose thallium studies showed some nonreproducibility, there were differences in exercise. Thallium results were identical in 15 of 16 patients whose ECG/exercise tests were reproducible (94%). Interobserver agreement was 95%. CONCLUSION: There was excellent reproducibility of 201Tl SPECT scintigraphy in patients who reproduced exercise test performance and symptoms.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Angiografia Coronária , Doença das Coronárias/epidemiologia , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Fatores de Tempo
14.
Clin Nucl Med ; 17(6): 431-8, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1319860

RESUMO

Thirty-three patients with biopsy-proven lung cancer and a total of 150 lesions diagnosed by conventional staging procedures were imaged using a Tc-99m labeled monoclonal Fab fragment of an IgG2B murine monoclonal antibody (MoAb) (NR-LU-10, NeoRx Corporation). Immunoscintigraphy demonstrated 100% of primary and 78% of metastatic lesions. MoAb imaging detected 88% of lesions in 12 small cell lung cancer (SCLC) patients and 77% of lesions in 21 non-small cell lung cancer (NSCLC) patients. Based on initial evaluation by other methods, 29 sites of MoAb activity were not associated with evidence of disease. Eleven of these were subsequently shown to represent sites of metastases; 18 remain unconfirmed. Four of ten patients studied with limited NSCLC had eight unsuspected lesions on MoAb imaging. Confirmation of unsuspected lesions in two patients altered initial clinical staging, and surgical therapy was abandoned. This study demonstrates that Tc-99m labeled NR-LU-10 can accurately stage patients with lung cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Radioimunodetecção , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/secundário , Carcinoma de Células Pequenas/patologia , Carcinoma de Células Pequenas/secundário , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único
15.
Radiology ; 177(2): 473-9, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2217788

RESUMO

Magnetic resonance (MR) imaging and phosphorus-31 MR spectroscopy were used to examine four patients with dermatomyositis and five control subjects. T2-weighted images of the thigh muscles of patients showed increased signal intensity, with focal and inhomogeneous involvement predominantly in the vastus lateralis and secondarily in the vastus intermedius and vastus medialis. T1 and T2 values of the vastus lateralis in patients were significantly higher than those of the control subjects. T1 values of the rectus femoris and biceps femoris with more generalized inflammation were moderately elevated but still significantly higher than those of the control subjects. P-31 MR spectra of the quadriceps muscles were obtained during rest, during exercise at two graded levels, and in recovery. Concentrations of adenosine triphosphate and phosphocreatine (PCr) in the diseased muscles were 30% below normal values, and the inorganic phosphate/PCr ratios were increased in the patients' muscles at rest and throughout exercise. The T1 and T2 values as well as the P-31 metabolite data correlated with symptoms and clinical assessment.


Assuntos
Dermatomiosite/diagnóstico , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Adulto , Dermatomiosite/metabolismo , Dermatomiosite/fisiopatologia , Estudos de Avaliação como Assunto , Exercício Físico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fosfatos/metabolismo , Fosfocreatina/metabolismo , Fósforo
16.
Clin Nucl Med ; 15(11): 783-6, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2292148

RESUMO

Radionuclide venography (RNV) is an accepted, reliable, and simple method for detecting thrombi of the deep venous system of the lower extremity. No universal agreement, however, has been established regarding specific techniques for tourniquet applications. In fact, present data reflect a general consensus that tourniquet use and location other than above the ankles has no appreciable or recognizable effect on study outcome. A prospective study was performed on 20 consecutive patients referred for RNV with the clinical impression of deep venous thrombosis (DVT). Each patient was studied initially with tourniquets above the knee and ankle, then with tourniquets above the ankle only, and finally without tourniquets. On the basis of standard criteria for DVT, 8 out of 20 patients were positive for DVT when the study was performed with tourniquets only above the ankle. Four of the eight positive studies became negative, however, when additional tourniquets were placed above the knees (20% false-positive rate). It is concluded that the routine application of additional tourniquets above the knees would eliminate a significant number of false-positive studies and should be part of an established routine protocol.


Assuntos
Tromboflebite/diagnóstico por imagem , Torniquetes , Adulto , Idoso , Tornozelo , Reações Falso-Positivas , Humanos , Joelho , Perna (Membro)/irrigação sanguínea , Pessoa de Meia-Idade , Estudos Prospectivos , Cintilografia , Agregado de Albumina Marcado com Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...