Phys Eng Sci Med ; 47(1): 261-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38150058

RESUMO

Diagnostic ultrasound (US) scanners are generally evaluated using proprietary quality assurance (QA) phantoms, but their prohibitively high cost may prevent organizations to perform the necessary tests. This study aimed to develop a low-cost gel wax phantom with targets to determine the lateral and axial resolution and diameter of a hyperechoic target in an US scanner. The acoustic property (AP) of gel wax, which includes the speed of sound (cus), acoustic impedance (Z), and attenuation coefficient (µ), were determined for multiple transducers operating at 2.25, 5, 10, 15, and 30 MHz. These results were compared to the AP of soft tissue. Two polytetrafluoroethylene (PTFE) rectangular frames with holes separated by 5, 10, and 20 mm were constructed. Nylon filaments and stainless-steel disc (SS disc) (diameter = 16.8 mm) were threaded through the frames and suitably placed in gel wax to obtain orthogonal targets in the phantom. The target dimensions obtained from computerized tomography (CT) and US images of the phantom were compared for phantom validation. The average cus=1431.4 m/s, mass density ρ = 0.87 g/cm3, Z = 1.24 MRayls, and µ ranged from 0.7 to 0.98 dB/cm/MHz for gel wax at 22 °C. The US image measurement exhibited a maximum error in determining the diameter of the SS disc, resulting in a value of 18 mm instead of its actual value of 16.8 mm. The phantom volume decreased by 1.8% in 62 weeks. The present phantom is affordable, stable, customizable, and can be used to evaluate diagnostic US scanners across multiple centers.


Assuntos
Tomografia Computadorizada por Raios X , Ultrassom , Ultrassonografia/métodos , Imagens de Fantasmas , Acústica
2.
Phys Eng Sci Med ; 43(4): 1171-1181, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32809141

RESUMO

Materials with acoustic properties similar to soft-tissue are essential as tissue-mimicking materials (TMMs) for diagnostic ultrasound (US). The velocity (cus), acoustic impedance (AI) and attenuation coefficient of US (µ) in a material collectively define its acoustic property. In this work, the acoustic properties of polychloroprene rubber, beeswax, and Carbomer-gel are determined. The pulse-echo technique is used to estimate cus and µ. The product of a sample density (ρ) and cus gives its AI. Using a reference based on the International Commission on Radiation Units and Measurements Report-61, Tissue Substitutes, Phantoms and Computational Modelling in Medical Ultrasound, the results are evaluated. The acceptance criteria are 1.043 ± 0.021 g/cm3 (ρ), 1561 ± 31.22 m/s (cus), 1.63 ± 0.065 MRayls (AI) and µ within 0.5-0.7 dB/cm/MHz. Sample computerized tomography (CT) and US scanning are performed to evaluate their similarities (contrast and speckle pattern) with respective images of the human liver (a clinical soft-tissue). The average errors in measuring cus and µ were 0.14% and 1.2% respectively. From the present findings, acoustic properties of polychloroprene and beeswax are unacceptable. However, the results of Carbomer-gel ρ = 1.03 g/cm3, cus = 1567 m/s, AI = 1.61 MRayls are satisfactory and µ = 0.73 dB/cm/MHz, is higher than the reference (4.3%). Carbomer-gel could produce CT and US images, efficiently mimicking the respective liver images. Carbomer-gel containing 95% water is a low-cost material with a simple formulation. Present results suggest, Carbomer- gel mimics soft-tissue and can be used as a TMM for diagnostic US.


Assuntos
Acústica , Neopreno , Resinas Acrílicas , Humanos , Ultrassonografia , Ceras
3.
Biomed Phys Eng Express ; 6(4): 045006, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33444267

RESUMO

More often the embolic materials in the brain create artefacts in the planning CT images that could lead to a dose variation in planned and delivered dose. The aim of the study was to evaluate the dosimetric effect of artefacts generated by the Onyx™ embolization material during Stereotactic Radiosurgery/Radiotherapy (SRS/SRT) planning. An in-house made novel Polymethyl Methacrylate (PMMA) head phantom (specially designed for SRS/SRT plans) was used for this purpose. For the evaluation process, we have created concentric ring structures around the central Onyx materials on both the CT sets (with and without Onyx material). The verification plans were generated using different algorithms namely Analytical Anisotropic Algorithm (AAA), Acuros XB and Monaco based Monte Carlo on both CT sets. Mean integral dose over the region of interest were calculated in both CT sets. The dosimetric results shows, due to the presence of Onyx material, relative variation in mean integral dose to the proximal structure (Ring 1) were -4.02%, -2.98%, and -2.49% for Monte Carlo, Acuros XB, and AAA respectively. Observed variations are attributed to the presence of artefacts due to Onyx material. Artefacts influence the accuracy of dose calculation during the planning. All the calculation algorithms are not equally capable to account such variations. Special cares are to be taken while choosing the calculation algorithms as it impacts the results of treatment outcome.


Assuntos
Radiometria/instrumentação , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Anisotropia , Artefatos , Desenho de Equipamento , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Polimetil Metacrilato/química , Radiometria/métodos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X