2.
Vopr Med Khim ; 43(1): 20-8, 1997.
Artigo em Russo | MEDLINE | ID: mdl-9281221

RESUMO

Integrated thin film biosensors for simultaneous measurement of L-glutamine and L-glutamate in a micro-flow cell were developed. Due to a novel glutaminase with an activity optimum in the neutral pH range a direct monitoring of glutamine in mammalian cell culture medium could be performed. The glutamine bienzyme sensor was prepared by coimmobilization of glutaminase with glutamate oxidase within a photo patterned poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogel membrane. The sensor response is linear in the concentration range of 55 mmol to 10 mmol glutamine/l. Additionally a glutamate biosensor is integrated on the sensor chip for difference measurement of possible glutamate interferences. The sensor chip can be used for at least 300 measurements without any alteration in the performance of its sensors. A new sensor chip with an integrated flow cell provides the possibility of simultaneous measurement of four different parameters at a cell volumina of 1 ml. Completing the microsystem a battery operated surface mounted device (SMD) potentiostat was developed to get a "lab on chip".


Assuntos
Técnicas Biossensoriais , Ácido Glutâmico/análise , Glutamina/análise , Concentração de Íons de Hidrogênio
3.
Anal Chem ; 68(18): 3173-9, 1996 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-8797377

RESUMO

A miniaturized device for simultaneous measurement of glucose and lactate levels was produced by means of photopatterning of enzyme-containing photosensitive membrane precursors. This device shows no cross-talk and a lifetime for both the glucose and the lactate sensors of more than 2 weeks when continuously operated in undiluted bovine serum. Linear response ranges of up to 40 mM for glucose and 25 mM for L-lactate, in combination with 95% response times of < 30 s, were realized. The devices are mass produced by means of thin-film technology on flexible carriers to give catheter-type multisensing devices for in vivo applications. Ex vivo experiments, performed with human volunteers, where the device was continuously operated in an extracorporeal, undiluted, heparinized blood stream for 6 h, gave a correlation of r > 0.98 with respect to laboratory techniques. Subcutaneous measurements of glucose levels in pigs were close to the corresponding blood levels obtained without in vivo calibration.


Assuntos
Técnicas Biossensoriais , Glicemia/análise , Ácido Láctico/sangue , Adulto , Animais , Eletroquímica , Feminino , Humanos , Masculino , Poli-Hidroxietil Metacrilato/análogos & derivados , Suínos
4.
Biosens Bioelectron ; 10(6-7): 527-32, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7612205

RESUMO

Integrated thin film biosensors were developed for the simultaneous measurement of L-glutamine and L-glutamate in a mu-flow cell. Due to a novel glutaminase with an activity optimum in the neutral pH range, direct monitoring of glutamine in a mammalian cell culture medium could be performed. The glutamine bienzyme sensor was prepared by co-immobilization of glutaminase with glutamate oxidase within a photopatterned poly(2-hydroxyethyl methacrylate) (pHEMA) hydrogel membrane. The sensor response was linear in the concentration range of 50 mumol to 10 mmol glutamine/l. Additionally, a glutamate biosensor was integrated on the sensor chip for difference measurement of possible glutamate interferences. The sensor-chip could be used for at least 300 measurements without any alteration in the performance of its sensors. A new sensor-chip with an integrated flow cell provided the possibility of simultaneous measurement of four different parameters at a cell volume of 1 microliter. In order to complete the microsystem, and in order to obtain a "lab on chip", a battery operated surface mounted device (SMD) potentiostat was developed.


Assuntos
Técnicas Biossensoriais , Ácido Glutâmico/análise , Glutamina/análise , Calibragem , Concentração de Íons de Hidrogênio