Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
Biosens Bioelectron ; 246: 115874, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38039732

RESUMO

Electrical bioimpedance is a non-invasive and radiation-free technique that was proposed to be used in different clinical areas, however, its practical use is limited due to its low capacity to discriminate between tissues. In order to overcome this limitation, our research group proposes to incorporate the contrast media into the electrical bioimpedance procedure. The main objective of the present study was to assess the crystalloid solutions as a possible contrast media to discriminate between different tissue types in the bioimpedance technique. Two medical-grade crystalloid solutions (Hartmann and NaCl 0.9%) were injected into three biological ex vivo models: kidney, liver, and brain. BIOPAC system was used to acquire bioimpedance data before and after the injections. The data was adjusted to the Debye electrical model. The analysis of measured values showed substantial bioimpedance disparities in tissues subjected to isotonic solutions. The NaCl solution exhibited more pronounced changes in electrical parameters compared to the Hartmann solution. Similarly, NaCl solution displayed superior discriminatory capabilities among tissues, with variations of 465%, 157%, and 206%. Distinct spectral modifications were identified, with tissues demonstrating unique responses at each frequency of analysis relative to untreated tissue. Variations in bandwidth alterations were discernible among tissues, providing clear distinctions. In conclusion, the research showed that the crystalloid solution exhibited greater sensitivity and superior tissue contrast at specific frequencies. This study's findings underscore the feasibility of implementing crystalloid solutions to enhance tissue discrimination, similar to the effects of contrast agents.


Assuntos
Técnicas Biossensoriais , Cloreto de Sódio , Soluções Cristaloides , Meios de Contraste , Impedância Elétrica
3.
Rev. mex. ing. bioméd ; 43(3): 1298, Sep.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1450144

RESUMO

ABSTRACT Spirometry is a test for the diagnosis of chronic obstructive pulmonary disease. It is a technique that can be intolerant due to the essential use of a mouthpiece and a clamp. This study proposes the use of electrical impedance tomogra phy to measure respiratory parameters. Patients underwent spirometry and three respiratory exercises. The imped ance signals were convolved, and the resultant was analyzed by fast Fourier transform. The frequency spectrum was divided into seven segments (R1 to R7). Each segment was represented in terms of quartiles (Q25%, Q50%, Q75%). Each quartile of each segment was correlated with the spirometric parameters to obtain a fitting equation. FVC was correlated 70% with the 3 quartiles of R7, 3 equations were obtained with a fit of 60%. FEV1 correlated 70% with the Q50% of R7, obtaining an equation with a fit of 40%. FEV1/FVC correlated 69% with Q75% of R2, obtaining an equation with a fit of 60%. Spirometric parameters can be estimated from the implied carrier frequency components of the ventilatory impedance signal.


RESUMEN La espirometría es una prueba para el diagnóstico de enfermedad pulmonar obstructiva crónica. Es una técnica que puede resultar intolerante debido al uso imprescindible de una boquilla y una de pinza. Este estudio propone el uso de la tomografía de impedancia eléctrica para medir los parámetros respiratorios. Los pacientes realizaron una espi rometría y tres ejercicios respiratorios. Las señales de impedancia fueron convolucionadas, y la resultante se analizó mediante una transformada rápida de Fourier. El espectro en frecuencias se dividió en siete segmentos (R1 a R7). Cada segmento se representó en términos de cuartiles (Q25%, Q50%, Q75%). Cada cuartil de cada segmento se co rrelacionó con los parámetros espirométricos para obtener una ecuación de ajuste. La FVC se correlacionó en un 70% con los 3 cuartiles de R7, se obtuvieron 3 ecuaciones con un ajuste del 60%. El FEV1 se correlacionó en un 70% con el Q50% de R7, obteniéndose una ecuación con un ajuste del 40%. El FEV1/FVC se correlacionó en un 69% con el Q75% de R2, obteniéndose una ecuación con un ajuste del 60%. Los parámetros espirométricos pueden ser estimados a partir de los componentes de frecuencia portadora implícitos de la señal de impedancia ventilatoria.

4.
Int Urol Nephrol ; 54(12): 3107-3115, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36001269

RESUMO

PURPOSE: Detrusor pressure-volume relationship evaluation by urodynamics provides useful clinical information; however, it is invasive, and requires specific installations. An alternative technique proposed by our research group is the electrical bioimpedance (BI) which is an easily performed and non-invasive method. In this work, we assess the relationship between BI and detrusor bladder pressure in adults with neurogenic lower urinary tract dysfunction. METHODS: A prospective observational study was conducted. 20 patients (11 females and 9 male) previously diagnosed with neurogenic bladder were included. All participants underwent simultaneously a urodynamic evaluation (UDS) and BI determination, and both examination signals were recorded and subjected to Shapiro-Wilks statistical test. A correlational statistical test was used to compare the pressure parameters (detrusor, vesical and abdominal) with their respective BI determinations. Subsequently, a linear regression test was performed to evaluate the concordance between BI and their respective pressure values. RESULTS: From the 20 correlations, between detrusor bladder pressure (PDET) and abdominal bioimpedance determinations (ZABD), obtained for all participants, 16 evidenced significant results over 90% (p < 0.05). CONCLUSIONS: A significantly high correlation between abdominal bioimpedance determinations and the detrusor bladder pressures was evidenced. These results should be confirmed in a larger group of participants.


Assuntos
Bexiga Urinaria Neurogênica , Adulto , Feminino , Humanos , Masculino , Bexiga Urinaria Neurogênica/diagnóstico , Bexiga Urinaria Neurogênica/etiologia , Urodinâmica , Bexiga Urinária , Procedimentos Cirúrgicos Urológicos , Estudos Prospectivos
5.
Neurogastroenterol Motil ; 32(4): e13785, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32017336

RESUMO

BACKGROUND: Meal-related symptoms are common in paediatric functional dyspepsia (FD). There are only a small number of paediatric studies assessing mechanisms for meal-related symptoms, and these have not utilized Rome IV criteria. The aim of the current study was to assess gastric myoelectric and autonomic nervous system (ANS) responses to both liquid and solid meals in youth with Rome IV-defined FD. METHODS: In healthy controls (N = 14) and youth with FD (N = 12), we recorded electrocardiograph (to assess heart rate variability; HRV) and electrogastrograph (EGG) signals before and after two test meals, one liquid and one solid. EGG parameters and HRV were assessed for the entire pre- and postprandial periods and in short time intervals. Additionally, liquid gastric emptying was assessed utilizing a 13 C-acetate breath test. KEY RESULTS: During the EGG, the dominant power increased with both meals in controls but not patients with FD. During HRV assessment, the low frequency to high frequency ratio was higher after the liquid meal in controls, despite being similar preprandial, as compared to patients with FD. In controls, both standard deviation of normal to normal waves (SDNN) and root mean square of successive ECG R peaks (R-R interval) differences (rMSSD) increased after the liquid meal (but not after the solid meal) in controls but not patients with FD. CONCLUSIONS AND INFERENCES: Youth with Rome IV-defined FD lacks the normal postprandial EGG dominant power response or autonomic nervous system response following a liquid meal. The latter appears to indicate a lack of ANS flexibility.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Dispepsia/fisiopatologia , Adolescente , Criança , Eletrocardiografia , Eletromiografia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Refeições , Período Pós-Prandial/fisiologia
6.
Dig Dis Sci ; 65(4): 1074-1081, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31549333

RESUMO

BACKGROUND/AIMS: While stress has been implicated in functional dyspepsia (FD), the mechanisms by which stress results in symptoms are not well defined. The aim of the current study was to assess gastric myoelectric and autonomic changes in response to a physical stressor in youth with FD. METHODS: In a group of healthy controls and pediatric FD subjects, we recorded ECG and EGG signals 30 min before and 60 min after, a cold pressor task (CPT). Gastric EGG and heart rate variability (HRV) parameters were calculated in pre- and post-CPT stages and in short intervals. RESULTS: The pre-CPT percent tachygastria was higher in FD subjects as compared to controls. However, CPT did not induce any EGG changes in either controls or FD subjects and the two groups did not differ from each other post-CPT. The CPT resulted in an increase in HRV and standard deviation of NN intervals in controls; there was no change in any HRV parameter in FD subjects. CONCLUSIONS: Acute physical stress does not appear to induce gastric electrical abnormalities in youth with FD. Youth with FD appear to lack the normal flexible autonomic response to a physical stressor.


Assuntos
Temperatura Baixa/efeitos adversos , Dispepsia/diagnóstico , Dispepsia/fisiopatologia , Motilidade Gastrointestinal/fisiologia , Frequência Cardíaca/fisiologia , Estresse Fisiológico/fisiologia , Adolescente , Criança , Eletrocardiografia/métodos , Fenômenos Eletromagnéticos , Feminino , Humanos , Masculino , Medição da Dor/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...