Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 62(29): 7560-7570, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37855462

RESUMO

The development of atmospheric hypersonic flight and re-entry capabilities requires the characterization of the thermo-chemical state of representative test environments. This study demonstrates the usage of multiplex nanosecond N 2 coherent anti-Stokes Raman scattering (CARS) to measure temperatures in an atmospheric, high-temperature (>6000K), air plasma plume, generated by an inductively coupled plasma torch. These are some of the highest temperatures ever accessed via gas-phase CARS, to our knowledge. Temperatures of N 2 in the equilibrium plasma plume are determined via theoretical fits to measured CARS spectra. We discuss the practical implementation of CARS at very high temperatures, including the scaling of the N 2 CARS signal strength from 300 to 6700 K, where the expected peak signal from the high-temperature plasma torch gases is two orders of magnitude less than commonly encountered in combustion environments. An intensified CCD camera enables single-laser-shot detection at temperatures as high as 6200 K, by increasing sensitivity and providing a time gate against intense background luminosity. We also discuss the impacts of unwanted two-beam CARS contributions from outside the nominal three-beam measurement volume. We present mean axial and radial temperature profiles, as well as time-series data derived from both single-laser-shot and accumulated CARS spectra. The single-laser-shot precision is 1.7%-2.6% at temperatures of 3500 to 6200 K. The presented results pave the way for the use of CARS at very high temperatures and the measurement of spatially resolved interface processes in high-enthalpy flows.

2.
Opt Lett ; 46(9): 2160-2163, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33929443

RESUMO

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic ${{\rm H}_2} \text{-} {\rm air}$ flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. This technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

3.
J Geophys Res Planets ; 125(8)2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33959468

RESUMO

Understanding how spacecraft alter planetary environments can offer important insights into key physical processes, as well as being critical to planning mission operations and observations. In this context, it is important to recognize that almost any powered lunar landing will be an active volatile release experiment, due to the release of exhaust gases during descent. This presents both an opportunity to study the interaction of volatiles with the lunar surface, and a need to predict how non-indigenous gases are dispersed, and how long they persist in the lunar environment. This work investigates these questions through numerical simulations of the transport of water vapor during a nominal lunar landing and for two lunar days afterwards. Simulation results indicate that the water vapor component of spacecraft exhaust is globally redistributed, with a significant amount reaching permanently shadowed regions (cold traps) near the closest pole, where temperatures are sufficiently low that volatiles may remain stable over geological timescales. Exospheric evolution and surface deposition patterns are highly sensitive to desorption activation energy, providing a means to constrain this critical parameter through landed or orbital measurements during future missions. Contamination of cold traps by exhaust gases is likely to scale with exhaust mass and proximity of the landing site to the poles. Exhaust propagation is perhaps the most widespread and long-lived impact of spacecraft operations on a nominally airless solar system body, and should be a key consideration in mission planning and in interpreting measurements made by landed lunar missions, particularly at near-polar regions. PLAIN LANGUAGE SUMMARY: There has been increasing interest lately in learning more about the origin and distribution of water on the Moon. However, whenever a spacecraft descends to land on the lunar surface, it releases water vapor and other gases into the lunar environment, complicating the situation. In this work, we use computer simulations to understand what happens to the water released by a spacecraft during a typical landing. The simulated landing creates a temporary, very thin atmosphere all around the Moon. The behavior of this atmosphere depends on how strongly water sticks to the lunar surface, such that comparing simulations to measurements of water in the lunar environment during and after future lunar landings could help us figure out the "stickiness" of the lunar surface - something that we don't yet accurately know, but is important to understanding the past, present and future distribution of water on the Moon. Our simulations also show that some spacecraft-delivered water travels to regions near the poles that are cold enough to trap water for very long periods of time. If the spacecraft is heavier, or lands closer to the poles, its influence on the lunar surface and atmosphere may be more significant.

4.
Appl Opt ; 52(20): 5007-21, 2013 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-23852217

RESUMO

A multiple-pass cell is aligned to focus light at two regions at the center of the cell. The two "points" are separated by 2.0 mm. Each probe region is 200 µm×300 µm. The cell is used to amplify spontaneous Raman scattering from a CH4-air laminar flame. The signal gain is 20, and the improvement in signal-to-noise ratio varies according to the number of laser pulses used for signal acquisition. The temperature is inferred by curve fitting high-resolution spectra of the Stokes signal from N2. The model accounts for details, such as the angular dependence of Raman scattering, the presence of a rare isotope of N2 in air, anharmonic oscillator terms in the vibrational polarizability matrix elements, and the dependence of Herman-Wallis factors on the vibrational level. The apparatus function is modeled using a new line shape function that is the convolution of a trapezoid function and a Lorentzian. The uncertainty in the value of temperature arising from noise, the uncertainty in the model input parameters, and various approximations in the theory have been characterized. We estimate that the uncertainty in our measurement of flame temperature in the least noisy data is ±9 K.

5.
Appl Opt ; 50(24): 4805-16, 2011 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-21857704

RESUMO

An improved Raman gain spectrometer for flame measurements of gas temperature and species concentrations is described. This instrument uses a multiple-pass optical cell to enhance the incident light intensity in the measurement volume. The Raman signal is 83 times larger than from a single pass, and the Raman signal-to-noise ratio (SNR) in room-temperature air of 153 is an improvement over that from a single-pass cell by a factor of 9.3 when the cell is operated with 100 passes and the signal is integrated over 20 laser shots. The SNR improvement with the multipass cell is even higher for flame measurements at atmospheric pressure, because detector readout noise is more significant for single-pass measurements when the gas density is lower. Raman scattering is collected and dispersed in a spectrograph with a transmission grating and recorded with a fast gated CCD array detector to help eliminate flame interferences. The instrument is used to record spontaneous Raman spectra from N(2), CO(2), O(2), and CO in a methane-air flame. Curve fits of the recorded Raman spectra to detailed simulations of nitrogen spectra are used to determine the flame temperature from the shapes of the spectral signatures and from the ratio of the total intensities of the Stokes and anti-Stokes signals. The temperatures measured are in good agreement with radiation-corrected thermocouple measurements for a range of equivalence ratios.

6.
Breast J ; 14(1): 61-7, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18186867

RESUMO

Sentinel lymph node (SLN) biopsy has emerged as an effective diagnostic tool in axillary staging in breast cancer. The commonly used technique employs isosulfan blue/patent blue V combined with radioactive colloid tracer. Methylene blue (MB) is a less expensive and readily available alternative dye. The study evaluated the safety and efficacy of MB in SLN localization. A retrospective study of 329 patients with early breast cancer who had SLN localization as part of an ethically approved prospective evaluation study of SLN localization technique was carried out. Lymph node positive, tumors >2 cm on clinical and radiological evaluation, those with previous breast and axillary surgery, neo-adjuvant chemotherapy were excluded from the study. One hundred seventy three patients underwent SLN localization using 1 mL of 1% MB, and a combined MB-radio colloid tracer technique was used in the other 156 patients. Allocation to the groups was by simple randomization. Injection of the dye and radioisotope was into the subdermal plane in the sub-areolar region. Patients underwent breast conservation surgery or mastectomy with SLN directed four node axillary sampling +/- axillary clearance. The lymph node was examined by standard microscopy. There were no reported complications with the use of MB aside from temporary tattooing. The technique failed in eight patients giving an identification rate of 97.6%. Ten of the 258 (3.9%) patients had false-negative SLN, with negative predictive value of 96.1%, sensitivity of predicting further axillary disease of 73%, specificity of 87.3%, and overall accuracy of 85.7%. Reported adverse reaction to isosulfan blue/patent blue V varied from minor to severe anaphylactic reactions (1-3%) requiring vigorous resuscitation. Subdermal sub-areolar injection of MB is safe and effective readily available dye for SLN localization in axillary staging of breast cancer with no major adverse reaction.


Assuntos
Neoplasias da Mama/patologia , Corantes , Linfonodos/patologia , Metástase Linfática/diagnóstico , Azul de Metileno , Biópsia de Linfonodo Sentinela , Neoplasias da Mama/diagnóstico , Feminino , Humanos , Metástase Linfática/patologia , Estadiamento de Neoplasias , Estudos Retrospectivos
7.
Diagn Microbiol Infect Dis ; 59(4): 389-94, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17878062

RESUMO

The conventional bacteriologic methods used for diagnosing pleural tuberculosis are less sensitive and time consuming. The objective of this study was to develop nonbacteriologic methods and to assess their potential utilities for the rapid diagnosis, especially in smear/culture-negative patients. One hundred forty patients with pleural effusion were investigated for tuberculous etiology by bacteriologic methods. Mycobacterium tuberculosis in the pleural fluid specimens was isolated in 11 patients. To establish a tuberculous etiology in the remaining 129 patients, we performed the following assays: a) estimation of tuberculosis-associated glycolipid antigen (TBGL) by a modified indirect enzyme-linked immunosorbent assay (ELISA), b) an immunocytochemical method for the demonstration of TBGL antigen in the Cytospin smears, and c) detection of mycobacterial DNA by polymerase chain reaction (PCR). Estimation of TBGL antigen by ELISA showed 100% specificity and overall 85.5% sensitivity. Immunocytochemistry could be applied only in those samples with adequate number of macrophages. PCR carried sensitivity and specificity of 87% and 93%, respectively. Estimation of TBGL antigen in pleural fluid specimens by ELISA has a definite role in establishing tuberculous etiology, particularly in those patients in whom bacteriologic methods did not demonstrate M. tuberculosis and also in those in whom a distinction between tuberculous and nontuberculous etiology was not possible based on the clinical and radiologic features of the thorax.


Assuntos
Mycobacterium tuberculosis/isolamento & purificação , Derrame Pleural , Tuberculose Pleural , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos de Bactérias/análise , DNA Bacteriano/análise , DNA Bacteriano/isolamento & purificação , Ensaio de Imunoadsorção Enzimática , Feminino , Glicolipídeos/análise , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Derrame Pleural/diagnóstico , Derrame Pleural/microbiologia , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade , Tuberculose Pleural/diagnóstico , Tuberculose Pleural/microbiologia
8.
Congenit Heart Dis ; 2(5): 347-50, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18377452

RESUMO

We report the case of an 8-month-old infant who was referred for mechanical circulatory support (extracorporeal membrane oxygenation). Aortogram was compatible with the diagnosis of anomalous origin of left coronary artery to pulmonary trunk. A definitive diagnosis of atresia of the left coronary ostium was only established intraoperatively. Patient underwent successful surgical angioplasty with an autologous pericardial patch.


Assuntos
Anomalias dos Vasos Coronários/cirurgia , Revascularização Miocárdica , Artéria Pulmonar/anormalidades , Aortografia , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico , Ecocardiografia , Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/etiologia , Hemorragia/etiologia , Hemorragia/terapia , Humanos , Lactente , Pneumopatias/etiologia , Pneumopatias/terapia , Masculino , Revascularização Miocárdica/métodos , Resultado do Tratamento
9.
10.
Appl Opt ; 44(31): 6786-95, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16270567

RESUMO

A tunable diode laser was used for absorption tomography in an axisymmetric atmospheric pressure flat-flame burner. A rapid tomographic inversion algorithm was used to facilitate the many reconstructions at a relatively sparse set of projections typical of laser absorption tomography. Profiles of temperature and CO2 mole fraction were measured simultaneously in methane-air flames. Absorption measurements were made near the R-branch bandhead at 4.17 microm to minimize interferences with other species, while providing good temperature and concentration sensitivity at flame conditions. The procedure showed the advantage of reconstructing detailed spectra at each radial node.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...