Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
JAMA ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023879

RESUMO

A woman with shortness of breath underwent imaging that showed an isolated dilatation in the mid ascending aorta and a bicuspid aortic valve but no pulmonary infiltrates, effusion, or embolism and no aortic stenosis or regurgitation; her family history is notable for aortic dissection. What would you do next?

2.
JTCVS Tech ; 24: 27-40, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38835563

RESUMO

Objective: To maximize successful repair of bicuspid aortic valves by adding figure-of-8 hitch-up stitches at commissures. Methods: From 2000 to 2022, bicuspid aortic valve repair was performed on 1112 patients at Cleveland Clinic, with 367 patients receiving figure-of-8 hitch-up stitches along with classical techniques, including Cabrol suture, cusp plication, raphe resection, and valve-sparing root replacement. Operative outcomes, repair durability, and survival were assessed in the figure-of-8 hitch-up stitches cohort, and outcomes were compared among 195 balancing-score-matched patient pairs who underwent bicuspid aortic valve repair with and without figure-of-8 hitch-up stitches. Results: Patients who underwent bicuspid aortic valve repair with figure-of-8 stitches had an operative mortality of 0.3% (1 of 367) and in-hospital reoperation for aortic valve dysfunction of 1.1% (4 of 367). At 10 years, prevalence of severe aortic regurgitation was 8.6%, mean gradient 24 mm Hg, freedom from aortic valve reoperation 75%, and survival 98%. In matched cohorts, operative mortality was similar (0.51% vs 0%; P > .9) as were morbidities, including in-hospital reoperation due to aortic valve dysfunction (1.0% vs 1.5%; P > .9). Comparable long-term outcomes were observed at 10 years (prevalence of severe aortic regurgitation of 8.7% vs 5.0% [P = .11], mean gradient 18 vs 17 mm Hg [P = .40]; freedom from aortic valve reoperation 80% vs 81% [P = .73]; and survival 99.5% vs 94.6% [P = .18]). Conclusions: Figure-of-8 hitch-up stitch is a safe bicuspid aortic valve repair technique. It increases the likelihood of a successful repair without increasing risk of cusp tear and achieves satisfactory long-term survival and durability when added to classical repair techniques.

3.
JTCVS Open ; 18: 12-30, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690415

RESUMO

Objective: Anterior mitral anular calcification, particularly in radiation heart disease, and previous valve replacement with destroyed intervalvular fibrosa are challenging for prosthesis sizing and placement. The Commando procedure with intervalvular fibrosa reconstruction permits double-valve replacement in these challenging conditions. We referenced outcomes after Commando procedures to standard double-valve replacements. Methods: From January 2011 to January 2022, 129 Commando procedures and 1191 aortic and mitral double-valve replacements were performed at the Cleveland Clinic, excluding endocarditis. Reasons for the Commando were severe calcification after radiation (n = 67), without radiation (n = 43), and others (n = 19). Commando procedures were referenced to a subset of double-valve replacements using balancing-score methods (109 pairs). Results: Between balanced groups, Commando versus double-valve replacement had higher total calcium scores (median 6140 vs 2680 HU, P = .03). Hospital outcomes were similar, including operative mortality (12/11% vs 8/7.3%, P = .35) and reoperation for bleeding (9/8.3% vs 5/4.6%, P = .28). Survival and freedom from reoperation at 5 years were 54% versus 67% (P = .33) and 87% versus 100% (P = .04), respectively. Higher calcium score was associated with lower survival after double-valve replacement but not after the Commando. The Commando procedure had lower aortic valve mean gradients at 4 years (9.4 vs 11 mm Hg, P = .04). After Commando procedures for calcification, 5-year survival was 60% and 59% with and without radiation, respectively (P = .47). Conclusions: The Commando procedure with reconstruction of the intervalvular fibrosa destroyed by mitral anular calcification, radiation, or previous surgery demonstrates acceptable outcomes similar to standard double-valve replacement. More experience and long-term outcomes are required to refine patient selection for and application of the Commando approach.

4.
J Thorac Cardiovasc Surg ; 167(1): 101-111.e4, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37532029

RESUMO

OBJECTIVE: To characterize residual aortic regurgitation (AR), identify its risk factors, and evaluate outcomes following aortic root replacement with aortic valve reimplantation. METHODS: From 2002 to 2020, 756 patients with a tricuspid aortic valve underwent elective reimplantation for aortic root aneurysm. AR on transthoracic echocardiograms before hospital discharge was graded as mild or greater. Machine learning was used to identify risk factors for residual AR and subsequent aortic valve reoperation. RESULTS: Sixty-five patients (8.6%) had mild (58 [7.7%]) or moderate (7 [0.93%]) residual postoperative AR. They had more severe preoperative AR (38% vs 12%; P < .0001), thickened cusps (7.7% vs 2.2%; P = .008), aortic valve repair (38% vs 23%; P = .004), and multiple returns to cardiopulmonary bypass for additional repair (11% vs 3.3%; P = .003) than those without AR. Predictors of residual AR were severe preoperative AR, smaller aortic root graft, and concomitant cusp repair. At 10 years, patients with versus without residual AR had more moderate or severe AR (48% vs 7.0%; P < .0001) and freedom from reoperation was worse (89% vs 98%; P < .0001). Residual AR was a risk factor for early reoperation. Concomitant coronary bypass, lower body mass index, and lower ejection fraction were risk factors for late reoperation. Ten-year survival was similar among patients with and without residual AR (97% vs 93%; P = .43). CONCLUSIONS: Residual AR after elective reimplantation of a tricuspid aortic valve for aortic root aneurysm is uncommon. Patients with severe preoperative AR and those who undergo valve repair have higher risk for residual AR, which can progress and increase risk of aortic valve reoperation.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Raiz da Aorta , Insuficiência da Valva Aórtica , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Reoperação , Reimplante/efeitos adversos , Estudos Retrospectivos
5.
Artigo em Inglês | MEDLINE | ID: mdl-38065521

RESUMO

OBJECTIVES: To describe patient characteristics and indications for surgical intervention, reoperation, and outcomes in patients with actin alpha-2 (ACTA2) variants. METHODS: A single-center retrospective cohort study with prospective follow-up was performed for 38 patients with an ACTA2 variant. RESULTS: From 1999 to 2020, 26 (70%) patients underwent surgery; 11 remain under surveillance (mean follow-up, 7.5 ± 5 years). Median age at index operation was 42 (range, 10-69) years, with 4 pediatric cases. Thoracic aortic aneurysm was present in 19 (73%) patients (mean adult max diameter, 5.2 ± 0.8 cm; pediatric z score, 10.7 ± 5.4). Aortic dissection was present in 13 (50%) patients, with 4 (15%) having type A dissection. Operations included replacement of the aortic root in 16 (17%), ascending aorta in 20 (77%), and aortic arch in 14 (54%) patients. Four (15%) patients had coronary artery disease, and 2 (7.7%) underwent concomitant coronary artery bypass grafting. There was no operative mortality, stroke, reoperation for bleeding, or dialysis-dependent renal failure; One (3.8%) patient developed acute on chronic kidney injury. Three patients (12%) required prolonged ventilation. Eleven (42%) patients underwent 26 reoperations, median time 45 (range, 4-147) months, including 5 open thoracoabdominal aneurysm repairs. CONCLUSIONS: Patients with ACTA2 variants frequently develop aortic aneurysm and are at risk of aortic dissection and coronary artery disease. However, age at diagnosis and symptoms at presentation are highly variable. Multiple operations are often required for disease management, particularly after dissection. Close monitoring and timely intervention are important in mitigating disease progression and improving outcomes.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38081538

RESUMO

OBJECTIVE: Patient characteristics, risks, and outcomes associated with reoperative multivalve cardiac surgery are poorly characterized. Effect of patient variables and surgical components of each reoperation were evaluated with regard to operative mortality. METHODS: From January 2008 to January 2022, 2324 patients with previous cardiac surgery underwent 2352 reoperations involving repair or replacement of multiple cardiac valves at Cleveland Clinic. Mean age was 66 ± 14 years. Number of surgical components representing surgical complexity (valve procedures, aortic surgery, coronary artery bypass grafting, and atrial fibrillation procedures) ranged from 2 to 6. Random forest for imbalanced data was used to identify risk factors for operative mortality. RESULTS: Surgery was elective in 1327 (56%), urgent in 1006 (43%), and emergency in 19 (0.8%). First-time reoperations were performed in 1796 (76%) and 556 (24%) had 2 or more previous operations. Isolated multivalve operations comprised 54% (1265) of cases; 1087 incorporated additional surgical components. Two valves were operated on in 80% (1889) of cases, 3 in 20% (461), and 4 in 0.09% (2). Operative mortality was 4.2% (98 out of 2352), with 1.7% (12 out of 704) for elective, isolated multivalve reoperations. For each added surgical component, operative mortality incrementally increased, from 2.4% for 2 components (24 out of 1009) to 17% for ≥5 (5 out of 30). Predictors of operative mortality included coronary artery bypass grafting, surgical urgency, cardiac, renal dysfunction, peripheral artery disease, New York Heart Association functional class, and anemia. CONCLUSIONS: Elective, isolated reoperative multivalve surgery can be performed with low mortality. Surgical complexity coupled with key physiologic factors can be used to inform surgical risk and decision making.

7.
JTCVS Tech ; 22: 159-168, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152191

RESUMO

Objective: The study objective was to determine repair durability and survival in patients with and without connective tissue disorders undergoing concomitant aortic valve reimplantation and mitral valve repair. Methods: From 2002 to 2019, 68 patients underwent concomitant aortic valve reimplantation and mitral valve repair, including 27 patients with Marfan syndrome (39.7%). Follow-up echocardiograms were analyzed using nonlinear multiphase mixed-effects cumulative logistic regression. The regurgitation grade over time was estimated by averaging patient-specific profiles. Survival and freedom from reoperation were estimated by the Kaplan-Meier method. Results: At 7 years, 11% of patients had aortic insufficiency greater than mild (severe in 2 patients). There was no difference in greater than mild aortic insufficiency between patients with or without Marfan syndrome (P = .37). Twenty percent of patients had progressed to mitral regurgitation greater than mild (severe in only 1 patient). The prevalence of recurrent mitral regurgitation was higher in those without Marfan syndrome, with greater than mild regurgitation increasing to 24% by 2 years and remaining constant thereafter (P = .04). Freedom from reoperation on the aortic valve or mitral valve was 83% at 10 years and did not differ between Marfan syndrome groups. There were no cases of perioperative mortality. Survival at 5 and 10 years was 94% and 87%, respectively, without a difference between those with and without Marfan syndrome. Conclusions: Patients can undergo a total repair strategy using combined aortic valve reimplantation and mitral valve repair procedures with a low risk of mortality and complications, with favorable freedom from both residual valve regurgitation and reoperation.

9.
Artigo em Inglês | MEDLINE | ID: mdl-37802330

RESUMO

BACKGROUND: Multisegment thoracic aortic disease typically requires total aortic arch replacement, affects a heterogenous population, and carries a high risk even at centers of excellence. Risk has been associated with the duration of operation and complexity of repair. A novel branched stented anastomosis frozen elephant trunk repair (B-SAFER) technique has been developed at our center and is currently being studied as a physician-sponsored investigation device exemption (PS-IDE). OBJECTIVE: This study aimed to assess the early safety of using this investigational technique to treat the proximal aorta in subjects with aortic disease involving multiple segments. METHODS: This prospective, single center, nonrandomized study enrolled patients undergoing B-SAFER for acute aortic syndrome (n = 73), aortic aneurysm with chronic aortic dissection (n = 68), degenerative aortic aneurysm (n = 33), or congenital aortic arch disease (n = 4). Devices are delivered antegrade under hypothermic circulatory arrest, and the arch reconstruction is performed as a single anastomosis single stent (SASS; n = 70), single anastomosis multiple stent (SAMA; n = 68), multiple anastomosis single stent (MASS; n = 21), or multiple anastomosis multiple stent (MAMS; n = 16) reconstruction. The primary safety endpoints were operative mortality, disabling stroke, and paraparesis/paralysis. RESULTS: Between May 27, 2021, and December 31, 2022, 178 patients underwent B-SAFER in the configurations and for the indications as described above. The median patient age was 65 years (range, 21 to 85 years), and 52 (29%) were female. The median cardiopulmonary bypass time was 188 minutes (interquartile range [IQR], 155 to 226 minutes), and 97% of the patients underwent repair with antegrade brain perfusion for a median of 46 minutes (IQR, 38 to 61 minutes). Operative mortality occurred in 10 patients (5.6%, including 6 [8.2%] with acute dissection, 2 [2.9%] with chronic dissection, 2 [6.1%] with degenerative aneurysm, and 0 with a congenital disorder), disabling stroke in 5 patients (2.9%), and paraparesis in 1 patient. Other serious complications included respiratory failure (n = 20; 11.4%) and acute kidney injury (n = 18; 10%). Thirty-two patients (18%) had undergone second-stage repairs (28 endovascular and 4 open), with 1 operative mortality after that procedure due to distal rupture. Estimated survival was 95% at 30 days, 88% at 90 days, 84% at 6 months, and 79% at 1 year. One-year survival differed by indication (72% for acute dissection, 91% for chronic dissection, 71% for degenerative aneurysm, and 100% for congenital disorders). CONCLUSIONS: The B-SAFER technique for total arch replacement in a complex cohort of patients with various indications for surgery is a safe and reproducible operation, as demonstrated by the early results from a very inclusive PS-IDE study. Further follow-up and analysis will help refine the technique. Novel devices to perform this procedure should be developed.

10.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37018150

RESUMO

OBJECTIVES: A better surgical approach for acute DeBakey type I dissection has been sought for decades. We compare operative trends, complications, reinterventions and survival after limited versus extended-classic versus modified frozen elephant trunk (mFET) repair for this condition. METHODS: From 1 January 1978 to 1 January 2018, 879 patients underwent surgery for acute DeBakey type I dissection at Cleveland Clinic. Repairs were limited to the ascending aorta/hemiarch (701.79%) or extended through the arch [extended classic (88.10%) or mFET (90.10%)]. Weighted propensity score matched established comparable groups. RESULTS: Among weighted propensity-matched patients, mFET repair had similar circulatory arrest times and postoperative complications to limited repair, except for postoperative renal failure, which was twice as high in the limited group [25% (n = 19) vs 12% (n = 9), P = 0.006]. Lower in-hospital mortality was observed following limited compared to extended-classic repair [9.1% (n = 7) vs 19% (n = 16), P = 0.03], but not after mFET repair [12% (n = 9) vs 9.5% (n = 8), P = 0.6]. Extended-classic repair had higher risk of early death than limited repair (P = 0.0005) with no difference between limited and mFET repair groups (P = 0.9); 7-year survival following mFET repair was 89% compared to 65% after limited repair. Most reinterventions following limited or extended-classic repair underwent open reintervention. All reinterventions following mFET repair were completed endovascularly. CONCLUSIONS: Without increasing in-hospital mortality or complications, less renal failure and a trend towards improved intermediate survival, mFET may be superior to limited or extended-classic repair for acute DeBakey type I dissections. mFET repair facilitates endovascular reintervention, potentially reducing future invasive reoperations and warranting continued study.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Aorta/cirurgia , Reoperação , Complicações Pós-Operatórias , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Aorta Torácica/cirurgia , Prótese Vascular
11.
J Thorac Cardiovasc Surg ; 166(6): 1561-1571.e8, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37061909

RESUMO

OBJECTIVE: The study objective was to determine the effect of sinutubular junction stabilization on long-term outcomes of bicuspid aortic valve repair. METHODS: From January 1998 to January 2020, 419 patients underwent bicuspid aortic valve repair with ascending aorta replacement and 421 without (bicuspid aortic valve repair alone). Propensity score matching (97 pairs) was used to compare outcomes. RESULTS: Before matching, prevalence of severe aortic regurgitation at 10 years was 5.4% after bicuspid aortic valve repair + ascending aorta replacement and 10% after bicuspid aortic valve repair alone; aortic valve gradient was 20 mm Hg after bicuspid aortic valve repair + ascending aorta replacement and 19 mm Hg after bicuspid aortic valve repair alone. Ten-year freedom from reoperation overall was 79% after bicuspid aortic valve repair + ascending aorta replacement and 75% after bicuspid aortic valve repair alone; freedom from late aortic regurgitation was 93% after bicuspid aortic valve repair + ascending aorta replacement and 92% after bicuspid aortic valve repair alone; and freedom from aortic stenosis was 87% after bicuspid aortic valve repair + ascending aorta replacement and 93% after bicuspid aortic valve repair alone. Ten-year survival was 95% after bicuspid aortic valve repair + ascending aorta replacement and 96% after bicuspid aortic valve repair alone. After matching, prevalence of severe aortic regurgitation at 10 years was 11% after bicuspid aortic valve repair + ascending aorta replacement and 9.1% after bicuspid aortic valve repair alone (P = .33); aortic valve gradient was 16 mm Hg after bicuspid aortic valve repair + ascending aorta replacement and 25 mm Hg after bicuspid aortic valve repair alone (P < .0001). Ten-year freedom from reoperation was 85% after bicuspid aortic valve repair + ascending aorta replacement and 72% after bicuspid aortic valve repair alone (P = .08) overall. Ten-year freedom from reoperation for late aortic regurgitation was 88% after bicuspid aortic valve repair + ascending aorta replacement and 86% after bicuspid aortic valve repair alone (P = .65). Freedom from aortic stenosis was 97% after bicuspid aortic valve repair + ascending aorta replacement and 91% after bicuspid aortic valve repair alone (P = .03). Ten-year survival was 96% after bicuspid aortic valve repair + ascending aorta replacement and 96% after bicuspid aortic valve repair alone (P = .16). CONCLUSIONS: Bicuspid aortic valve repair with or without ascending aorta replacement is associated with good short- and long-term outcomes. Bicuspid aortic valve repair + ascending aorta replacement has a minimal effect on long-term repair durability. Sinutubular junction stabilization should not be performed for the sole purpose of long-term repair durability.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Humanos , Doença da Válvula Aórtica Bicúspide/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Reoperação , Resultado do Tratamento , Estudos Retrospectivos
12.
J Thorac Cardiovasc Surg ; 166(6): 1617-1626.e6, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36740496

RESUMO

OBJECTIVE: The durability of reimplanted myxomatous aortic valves in root replacements for patients with connective tissue disorders (CTD) is unclear; therefore, we sought to evaluate the long-term resilience of these repairs. METHODS: From January 1980 to January 2020, 214 patients with CTD and 645 without CTD underwent primary, elective aortic valve reimplantation operations at Cleveland Clinic. The CTD cohort included 164 (77%) with Marfan, 23 (11%) with Loeys-Dietz, and 7 (3.3%) with Ehlers-Danlos CTD. We accounted for differing patient characteristics between the groups by propensity score matching to compare outcomes, yielding 96 matched pairs. Longitudinal echocardiographic measures were compared using nonlinear mixed effects models. RESULTS: In the CTD cohort, there were no operative mortalities (30-day or in-hospital), 1 (0.47%) stroke, and 1 (0.47%) early in-hospital reoperation for valve dysfunction. Ten-year prevalence of no aortic regurgitation was 86%, mild 11%, and moderate 3%. Ten-year freedom from reoperation was 97%. In propensity matched cohorts, there were no significant differences in in-hospital outcomes, longitudinal aortic regurgitation and mean gradient, risk of reoperation on the aortic valve, or risk of late death. CONCLUSIONS: Aortic valve reimplantation is a durable operation in patients with CTD and root aneurysms. These patients do not experience early degeneration of their reimplanted aortic valves.


Assuntos
Insuficiência da Valva Aórtica , Doenças do Tecido Conjuntivo , Síndrome de Marfan , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doenças do Tecido Conjuntivo/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Reoperação , Reimplante/efeitos adversos , Tecido Conjuntivo , Resultado do Tratamento , Estudos Retrospectivos , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/cirurgia
14.
J Endovasc Ther ; 30(4): 550-560, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35587698

RESUMO

BACKGROUND: Operative mortality for type A aortic dissection is still 10-20% at centers of excellence. Additionally, 10-20% are not considered as viable candidates for open surgical repair and not offered life-saving emergency surgery. ARISE is a multicenter investigation evaluating the novel GORE® Ascending Stent Graft (ASG; Flagstaff, AZ). OBJECTIVE: The purpose of this study is to assess early feasibility of using these investigational devices to treat ascending aortic dissection. METHODS: This a prospective, multicenter, non-randomized, single-arm study that enrolls patients at high surgical risk with appropriate anatomical requirements based on computed tomography imaging at 7 of 9 US sites. Devices are delivered transfemorally under fluoroscopic guidance. Primary endpoint is all-cause mortality at 30 days. Secondary endpoints include major adverse cardiovascular and cerebrovascular events (MACCE) at 30 days, 6 months, and 12 months. RESULTS: Nineteen patients were enrolled with a mean age of 75.7 years (range 47-91) and 11 (57.9%) were female. Ten (52.6%) had DeBakey type I disease, and the rest were type II. Sixteen (84.2%) of the patients were acute. Patients were treated with safe access, (7/19 (36.8%) percutaneous, 10/19 (52.6%) transfemoral, 2/19 (10.5%) iliac conduit), delivery, and deployment completed in all cases. Median procedure time was 154 mins (range 52-392) and median contrast used was 111 mL (range 75-200). MACCE at 30 days occurred in 5 patients including mortality 3/19 (15.8%), disabling stroke in 1/19 (5.3%), and myocardial infarction in 1/19 (5.3%). CONCLUSION: Results from the ARISE early feasibility study of a specific ascending stent graft device to treat ascending aortic dissection are promising.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Dissecção da Aorta Ascendente , Procedimentos Endovasculares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Prótese Vascular , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Stents , Complicações Pós-Operatórias/etiologia , Aneurisma da Aorta Torácica/cirurgia
15.
JTCVS Open ; 16: 105-122, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204640

RESUMO

Objective: During aortic valve reimplantation, cusp repair may be needed to produce a competent valve. We investigated whether the need for aortic valve cusp repair affects aortic valve reimplantation durability. Methods: Patients with tricuspid aortic valves who underwent aortic valve reimplantation from January 2002 to January 2020 at a single center were retrospectively analyzed. Propensity matching was used to compare outcomes between patients who did and did not require aortic valve cusp repair. Results: Cusp repair was performed in 181 of 756 patients (24%). Patients who required cusp repair were more often male, were older, had more aortic valve regurgitation, and less often had connective tissue disease. Patients who underwent cusp repair had longer aortic clamp time (124 ± 43 minutes vs 107 ± 36 minutes, P = .001). In-hospital outcomes were similar between groups and with no operative deaths. A total of 98.3% of patients with cusp repair and 99.3% of patients without cusp repair had mild or less aortic regurgitation at discharge. The median follow-up was 3.9 and 3.2 years for the cusp repair and no cusp repair groups, respectively. At 10 years, estimated prevalence of moderate or more aortic regurgitation was 12% for patients with cusp repair and 7.0% for patients without cusp repair (P = .30). Mean aortic valve gradients were 6.2 mm Hg and 8.0 mm Hg, respectively (P = .01). Ten-year freedom from reoperation was 99% versus 99% (P = .64) in the matched cohort and 97% versus 97%, respectively (P = .30), in the unmatched cohort. Survival at 10 years was 98% after cusp repair and 93% without cusp repair (P = .05). Conclusions: Aortic valve reimplantation for patients with tricuspid aortic valves has excellent long-term results. Need for aortic valve cusp repair does not affect long-term outcomes and should not deter surgeons from performing valve-sparing surgery.

16.
J Card Surg ; 37(12): 5451-5454, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36251267

RESUMO

Redo cardiac surgery can present a unique set of challenges even to the experienced surgeon. Although outcomes have steadily improved in the modern era; if an intraoperative adverse event occurs, there is a 5% incidence of mortality and 19% incidence of myocardial infarction, stroke or death. Overall, the modern incidence of mortality at reoperation varies but be segregated into low and higher risk cohorts depending on the planning computed tomography imaging and risk to substernal structures on re-entry. Patients with ascending aortic or root pseudoaneurysms represent a particularly difficult subset of high-risk patients requiring reoperative cardiac surgery due to the danger of exsanguination and air embolization. The gold standard for management of such cases remains the use of deep hypothermic circulatory arrest (DHCA) to achieve safe re-entry in such cases however this can result in unpredictable DHCA duration depending on the degree of pericardial adhesions. We report a case of aortic pseudoaneurysm in a patient with patent coronary grafts managed using an endoballoon precisely positioned relative to the proximal anastomoses resulting in a safe surgical re-entry and shorter DHCA time.


Assuntos
Falso Aneurisma , Procedimentos Cirúrgicos Cardíacos , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Resultado do Tratamento , Aorta/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Coração , Estudos Retrospectivos , Reoperação
17.
Artigo em Inglês | MEDLINE | ID: mdl-36243238

RESUMO

To characterize patient risk profiles and outcomes associated with staged ultra-hybrid repair of extensive aortic disease, in which open thoracoabdominal completion was performed after thoracic stent grafting. From 1/2006 to 1/2021, 92 patients underwent open thoracoabdominal repair of chronic dissection (n=58, 63%), degenerative aneurysm (n=28, 30%), endoleak (n=4, 4.3%), or symptomatic acute type B dissection (n=2, 2.2%) after descending thoracic stent grafting (69, 75%), frozen elephant trunk (5, 5%), or both (18, 20%). The surgical graft was sewn to the distal endovascular device in situ, reducing the extent of the open procedure and eliminating the need for hypothermic circulatory arrest. Mean age was 58±13 years, 89 (97%) were hypertensive, 38 (43%) had chronic obstructive pulmonary disease, 63 (72%) were smokers, 20 (24%) had a prior stroke, and 33 (36%) had a suspected or confirmed heritable aortic condition. Hospital mortality was 7.6% (n=7). Complications included dialysis (16, 20%), tracheostomy (8, 8.7%), stroke (5, 5.7%), and permanent paralysis (6, 6.9%). Survival at 1, 3, and 5 years was 80%, 71%, and 66%, respectively. Mortality was associated with higher blood urea nitrogen and longer distance between the distal endograft edge and proximal patent visceral vessel (P=0.004 and .01, respectively). Patients with extensive aortic disease undergoing open aortic repair after thoracic stent grafting are often young with chronic dissection, multiple comorbidities, or a heritable aortic condition. Success of staged ultra-hybrid operations demonstrates open and endovascular repair strategies are complementary, even when performed in a high-risk patient population.

18.
Catheter Cardiovasc Interv ; 100(5): 860-867, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36116028

RESUMO

BACKGROUND: Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has emerged in recent years as a safe alternative to redo surgery in high-risk patients. Although early results are encouraging, data beyond short-term outcomes are lacking. Herein, we aimed to assess the 2-year outcomes after ViV-TAVI. METHODS: Patients undergoing ViV-TAVI for degenerated surgical valves between 2013 and 2019 at the Cleveland Clinic were reviewed. The coprimary endpoints were all-cause mortality and congestive heart failure (CHF) hospitalizations. We used time-to-event analyses to assess the primary outcomes. Further, we measured the changes in transvalvular gradients and the incidence of structural valve deterioration (SVD). RESULTS: One hundred and eighty-eight patients were studied (mean age = 76 years; 65% males). At 2 years of follow-up, all-cause mortality and CHF hospitalizations occurred in 15 (8%) and 28 (14.9%) patients, respectively. On multivariable analysis, the postprocedural length of stay was a significant predictor for both all-cause mortality (hazard ratio [HR] = 1.1; 95% confidence interval [CI]: 1.01, 1.19) and CHF hospitalization (HR = 1.16; 95% CI: 1.07, 1.27). However, the internal diameter of the surgical valve was not associated with significant differences in both primary endpoints. For hemodynamic outcomes, nine patients (4.8%) developed SVD. The mean and peak transvalvular pressure gradients remained stable over the follow-up period. CONCLUSION: ViV-TAVI for degenerated surgical valves was associated with favorable 2-year clinical and hemodynamic outcomes. Further studies are needed to better understand the role of ViV-TAVI as a treatment option in the life management of aortic valve disease.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/métodos
19.
JTCVS Tech ; 14: 1-8, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35967241

RESUMO

Objectives: Debakey type I and IIIb aortic dissections are complicated by extension along the full length of the aorta. Over the long term, the thoracoabdominal aorta in these patients often continues to degenerate, requiring endovascular or open repair. The purpose of this investigation is to determine the early clinical outcome on aortic remodeling using a composite thoracic stent graft and thoracoabdominal bare metal extension stenting strategy. Methods: From April 2019 to April 2021, 73 patients with Debakey I/IIIb aortic dissection underwent endovascular stent graft repair of the descending thoracic aorta and repair of the thoracoabdominal aorta using bare metal extension stenting. Preoperative and follow-up surveillance computed tomography imaging scans were analyzed. Results: Fifty-three (73%) patients had a Debakey I aortic dissection, and 50 (69%) patients underwent surgery during the chronic (time to surgery >30 days) dissection phase. Mortality at 30 days was 4% (3 hyperacute patients). Stroke occurred in 3 (4%), paraparesis in 2 (2.7%), and acute renal failure requiring dialysis occurred in 2 (2.7%) patients. On postoperative and follow-up computed tomography, there was a significant increase in false lumen thrombosis (P < .001). This coincided with a significant increase in true lumen fraction suggestive of positive aortic remodeling (P < .001) at the time of latest follow-up. Conclusions: Altering the course of aortic remodeling, with placement of a dissection stent in the thoracoabdominal aorta simultaneous with descending thoracic aortic repair may promote true lumen re-expansion and false lumen thrombosis during acute and chronic dissection phases.

20.
Innovations (Phila) ; 17(3): 201-208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35604783

RESUMO

Objective: Patients with thoracic aortic disease commonly present with concomitant multisegment pathology. We describe the patient population, analyze outcomes, and define the patient selection strategy for valve-preserving aortic root reimplantation (VPARR) combined with the arch procedure. Methods: From 2008 to 2018, 98 patients underwent VPARR combined with the aortic arch procedure (hemi-arch, 50% [n = 49, limited repair]; total arch, 50% [n = 49, complete repair] including 39 with elephant trunk). Indications for surgery were aneurysmal disease (61%) and aortic dissection (39%). The median follow-up was 17 months (IQR, 8 to 60 months). Results: There were no operative deaths or paraplegia, and 5 patients underwent re-exploration for bleeding. During follow-up, 2 patients required aortic valve replacement for severe aortic insufficiency at 1 and 5 years, and 4 patients died. In the limited repair group, 1 patient underwent reintervention for aortic arch replacement, whereas 4 patients underwent planned intervention (1 endovascular and 3 open thoracoabdominal aortic repair). In the complete repair group, 23 patients underwent planned intervention (15 endovascular and 8 open thoracoabdominal repair). Conclusions: Single-stage, complete, proximal aortic repair including VPARR combined with total aortic arch replacement is as safe and feasible to perform as limited arch repair and facilitates further intervention in carefully selected patients with diffuse aortic pathology at centers of expertise.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Humanos , Seleção de Pacientes , Reimplante , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...