1.
Methods Mol Biol ; 2313: 259-268, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34478143

RESUMO

The quantitation of therapeutic antibodies by mass spectrometry often utilizes a surrogate peptide approach following enzymatic digestion of the antibody. Although this approach has been widely adopted, it is labor intensive with limited throughput in most instances. In addition, this approach can pose challenges when attempting to infer details such as quantity and modification state of the intact analyte. Recent enhancements in instrumentation and sample preparation have enabled quantitation through mass spectrometry detection of the intact protein circumnavigating many limitations of the surrogate peptide approach. Presented here is a method for quantitative analysis of therapeutic monoclonal antibodies (mAb) at the fully intact level in a complex pharmacokinetic study. This methodology yielded sensitivity down to 0.1µg/mL from 30µL of a biological sample volume to be utilized across multiple preclinical species without the need for pooling.


Assuntos
Espectrometria de Massas , Anticorpos Monoclonais , Peptídeos
2.
Analyst ; 145(8): 3148-3156, 2020 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32191233

RESUMO

Continued interest in protein therapeutics has motivated the development of improved bioanalytical tools to support development programs. LC-MS offers specificity, sensitivity, and multiplexing capabilities without the need for target-specific reagents, making it a valuable alternative to ligand binding assays. Immunoaffinity purification (IP) and enzymatic digestion are critical, yet extensive and time-consuming components of the "gold standard" bottom-up approach to LC-MS-based protein quantitation. In the present work, commercially available technology, based on membrane-immobilized reagents in spin column and plate format, is applied to reduce IP and digestion times from hours to minutes. For a standard monoclonal antibody, the lower limit of quantitation was 0.1 ng µL-1 compared to 0.05 ng µL-1 for the standard method. A pharmacokinetics (PK) study dosing Herceptin in rat was analyzed by both the membrane and the standard method with a total sample processing time of 4 h and 20 h, respectively. The calculated concentrations at each time point agreed within 8% between both methods, and PK values including area under the curve (AUC), half-life (T1/2), mean residence time (MRT), clearance (CL), and volume of distribution (Vdss) agreed within 6% underscoring the utility of the membrane methodology for quantitative bioanalysis workflows.


Assuntos
Cromatografia de Afinidade/métodos , Enzimas Imobilizadas/química , Membranas Artificiais , Trastuzumab/análise , Sequência de Aminoácidos , Animais , Masculino , Estudo de Prova de Conceito , Proteólise , Ratos Sprague-Dawley , Proteína Estafilocócica A/química , Fatores de Tempo , Trastuzumab/química , Trastuzumab/isolamento & purificação , Trastuzumab/farmacocinética , Tripsina/química
3.
Bioanalysis ; 11(3): 203-213, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30734579

RESUMO

Aim: The quantitation of therapeutic antibodies by MS often utilizes a surrogate peptide approach. Recent enhancements in instrumentation and sample preparation have enabled quantitation by detection of the intact molecule using MS. Methods & Results: A comparison of three methods for quantitative analysis of therapeutic monoclonal antibodies including analysis after deglycosylation, after hinge digestion and at the fully intact antibody level is reported. The optimized methodology provided sensitivity down to 0.1 µg/ml and a lower limit of quantitation of 0.5 ug/ml from a 30 µl sample volume. Conclusion: Application of this approach to a pharmacokinetic study compared with a conventional surrogate peptide and a ligand-binding assays provided consistent data with direct detection of the dosed molecule.

4.
Bioanalysis ; 10(13): 1039-1054, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29952237

RESUMO

AIM: The requirements for developing antibody biotherapeutics benefit from understanding the nature and relevant aspects of the entire molecule. The method presented herein employs on-line multidimensional LC-quadrupole time-of-flight (QTOF)-MS for the quantitative determination of an antibody isolated from biological samples while maintaining the intact native biologically active conformation of the antibody. RESULTS: Following method optimization for a model antibody, an incurred biotherapeutic in cynomologus monkey was quantified in its intact top-down native conformation. A partial method validation demonstrated acceptable precision and accuracy although improved sensitivity requires further studies. CONCLUSION: An on-line multidimensional LC-MS approach presents a proof-of-principle example for quantifying an intact, native antibody isolated from an incurred biological sample via immunoaffinity techniques coupled with top-down QTOF LC-MS bioanalysis.


Assuntos
Anticorpos Monoclonais/sangue , Animais , Anticorpos Monoclonais/metabolismo , Cromatografia Líquida , Haplorrinos , Espectrometria de Massas , Camundongos
5.
Anal Chem ; 90(1): 866-871, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29206445

RESUMO

Large molecule quantitation by LC-MS/MS commonly relies on bottom-up or so-called surrogate peptide measurements to infer the whole-molecule concentration. This can lead to questions about what is actually being measured in the assay (intact drug and/or other drug related material). An intact sequential affinity capture (ISAC) assay was developed utilizing two different immunoaffinity (IA) reagents. The reagents were selective for the heavy and light chain of a monoclonal antibody, which when used consecutively, ensures that only the intact form of the antibody is represented by the surrogate peptide. The approach provided comparable results to a traditional sandwich IA assay indicating similar capture populations. The use of an initial ISAC assessment of affinity capture purification, should add a degree of confidence in the use of a single IA-LC-MS/MS quantitation assay.


Assuntos
Anticorpos Monoclonais/sangue , Bioensaio/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Anticorpos Monoclonais/química , Macaca mulatta , Proteólise , Tripsina/química
6.
Bioanalysis ; 8(7): 649-59, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26977979

RESUMO

AIM: Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. METHODS & RESULTS: We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. CONCLUSION: Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.


Assuntos
Proteínas/análise , Sequência de Aminoácidos , Animais , Anticorpos Monoclonais/análise , Anticorpos Monoclonais/farmacocinética , Automação , Coleta de Amostras Sanguíneas , Cromatografia Líquida de Alta Pressão , Teste em Amostras de Sangue Seco , Meia-Vida , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Miniaturização , Dados de Sequência Molecular , Proteínas/farmacocinética , Espectrometria de Massas em Tandem
7.
J Proteome Res ; 14(4): 1900-10, 2015 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-25748058

RESUMO

A majority of high-grade (HG) serous ovarian cancer (SOC) patients develop resistant disease despite high initial response rates to platinum/paclitaxel-based chemotherapy. We identified shed/secreted proteins in preclinical models of paclitaxel-resistant human HGSOC models and correlated these candidate proteins with patient outcomes using public data from HGSOC patients. Proteomic analyses of a HGSOC cell line secretome was compared to those from a syngeneic paclitaxel-resistant variant and from a line established from an intrinsically chemorefractory HGSOC patient. Associations between the identified candidate proteins and patient outcome were assessed in a discovery cohort of 545 patients and two validation cohorts totaling 795 independent SOC patients. Among the 81 differentially abundant proteins identified (q < 0.05) from paclitaxel-sensitive vs -resistant HGSOC cell secretomes, AKAP12 was verified to be elevated in all models of paclitaxel-resistant HGSOC. Furthermore, elevated AKAP12 transcript expression was associated with worse progression-free and overall survival. Associations with outcome were observed in three independent cohorts and remained significant after adjusted multivariate modeling. We further provide evidence to support that differential gene methylation status is associated with elevated expression of AKAP12 in taxol-resistant ovarian cancer cells and ovarian cancer patient subsets. Elevated expression and shedding/secretion of AKAP12 is characteristic of paclitaxel-resistant HGSOC cells, and elevated AKAP12 transcript expression is a poor prognostic and predictive marker for progression-free and overall survival in SOC patients.


Assuntos
Proteínas de Ancoragem à Quinase A/metabolismo , Proteínas de Ciclo Celular/metabolismo , Metilação de DNA/genética , Resistencia a Medicamentos Antineoplásicos/fisiologia , Regulação Neoplásica da Expressão Gênica/fisiologia , Neoplasias Ovarianas/diagnóstico , Paclitaxel/metabolismo , Estudos de Coortes , Feminino , Humanos , Avaliação de Resultados da Assistência ao Paciente , Prognóstico , Proteômica/métodos
8.
J Am Soc Mass Spectrom ; 22(6): 1105-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21953052

RESUMO

We modified a dual pressure linear ion trap Orbitrap to permit infrared multiphoton dissociation (IRMPD) in the higher energy collisional dissociation (HCD) cell for high resolution analysis. A number of parameters, including the pressures of the C-trap and HCD cell, the radio frequency (rf) amplitude applied to the C-trap, and the HCD DC offset, were evaluated to optimize IRMPD efficiency and maintain a high signal-to-noise ratio. IRMPD was utilized for characterization of phosphopeptides, supercharged peptides, and N-terminal modified peptides, as well as for top-down protein analysis. The high resolution and high mass accuracy capabilities of the Orbitrap analyzer facilitated confident assignment of product ions arising from IRMPD.


Assuntos
Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Peptídeos/química , Sequência de Aminoácidos , Dados de Sequência Molecular , Processos Fotoquímicos , Proteômica/instrumentação , Proteômica/métodos
9.
J Am Soc Mass Spectrom ; 20(3): 377-84, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19027323

RESUMO

A strategy for improving the sequencing of peptides by infrared multiphoton dissociation (IRMPD) in a linear ion trap mass spectrometer is described. We have developed an N-terminal derivatization reagent, 4-methylphosphonophenylisothiocyanate (PPITC), which allows the attachment of an IR-chromogenic phosphonite group to the N-terminus of peptides, thus enhancing their IRMPD efficiencies. After the facile derivatization process, the PPITC-modified peptides require shorter irradiation times for efficient IRMPD and yield extensive series of y ions, including those of low m/z that are not detected upon traditional CID. The resulting IRMPD mass spectra afford more complete sequence coverage for both model peptides and tryptic peptides from cytochrome c. We compare the effectiveness of this derivatization/IRMPD approach to that of a common N-terminal sulfonation reaction that utilizes 4-sulfophenylisothiocyanate (SPITC) in conjunction with CID and IRMPD.


Assuntos
Espectrometria de Massas/métodos , Peptídeos/química , Análise de Sequência de Proteína/métodos , Tiocianatos/química , Benzenossulfonatos/química , Isotiocianatos/química , Organofosfonatos/química
10.
Anal Chem ; 80(13): 4807-19, 2008 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-18517224

RESUMO

We have developed a new IR chromogenic cross-linker (IRCX) to aid in rapidly distinguishing cross-linked peptides from unmodified species in complex mixtures. By incorporating a phosphate functional group into the cross-linker, one can take advantage of its unique IR absorption properties, affording selective infrared multiphoton dissociation (IRMPD) of the cross-linked peptides. In a mock mixture of unmodified peptides and IRCX-cross-linked peptides (intramolecularly and intermolecularly cross-linked), only the peptides containing the IRCX modification were shown to dissociate upon exposure to 50 ms of 10.6-microm radiation. LC-IRMPD-MS proved to be an effective method to distinguish the cross-linked peptides in a tryptic digest of IRCX-cross-linked ubiquitin. A total of four intermolecular cross-links and two dead-end modifications were identified using IRCX and LC-IRMPD-MS. IRMPD of these cross-linked peptides resulted in secondary dissociation of all primary fragment ions containing the chromophore, producing a series of unmodified b- or y-type ions that allowed the cross-linked peptides to be sequenced without the need for collision-induced dissociation.


Assuntos
Reagentes de Ligações Cruzadas/química , Organofosfatos/química , Peptídeos/química , Succinimidas/química , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Reagentes de Ligações Cruzadas/síntese química , Organofosfatos/síntese química , Succinimidas/síntese química , Ubiquitina/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...