1.
Catheter Cardiovasc Interv ; 84(5): 734-41, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24948549

RESUMO

BACKGROUND: The Cappella Sideguard (CS) sidebranch stent is a self-expanding, thin-strut, nitinol device with anatomic flaring at the sidebranch ostium designed to treat bifurcation lesions. OBJECTIVE: To evaluate the mechanism of long-term lumen patency of the novel, self-expanding CS sidebranch stent compared with a balloon-expandable stent in the main vessel. METHODS: We performed intravascular ultrasound postintervention and at follow-up in 24 CS stents and in 28 balloon-expandable drug-eluting stents deployed in the corresponding main vessel. Thirteen patients also had optical coherence tomography (OCT) at follow-up to evaluate neointimal hyperplasia and strut coverage. RESULTS: CS stent area at the sidebranch carina increased significantly from 3.8 ± 1.2 mm(2) postintervention to 4.6 ± 1.2 mm(2) at follow-up (P < 0.001), resulting in no change in lumen area (3.8 ± 1.2 mm(2) to 3.7 ± 1.2 mm(2) , P = 0.72) despite a neointimal area at follow-up of 0.9 ± 0.8 mm(2) . Volumetric changes were similar, and the distribution of neointimal hyperplasia peaked 1-2 mm distal to the carina. Change of lumen volume inversely correlated to the neointimal volume (R = -0.48, P < 0.001), but correlated positively to the change in stent volume (R = 0.52, P < 0.0001). By OCT, most CS struts were covered (100% [98.9, 100]) at the bifurcation site, whereas 61% of floating DES struts that crossed the sidebranch were covered by smooth tissue with a similar texture compared with neointima. CONCLUSION: Although neointimal hyperplasia accumulates within the CS stent mainly 1-2 mm distal to the carina, the self-expanding CS stent may be effective in maintaining an adequate patency in the sidebranch by continued stent expansion noted at follow-up.


Assuntos
Estenose Coronária/terapia , Stents Farmacológicos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Grau de Desobstrução Vascular/fisiologia , Idoso , Ligas , Análise de Variância , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Neointima/patologia , Neointima/fisiopatologia , Maleabilidade , Estudos Prospectivos , Desenho de Prótese , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...