Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mol Recognit ; 17(1): 67-75, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14872539

RESUMO

Conformational analysis of peptide 1, H-Leu-Leu-Ile-Leu-OMe on complexing with macro cycle calix[8]arene has been carried out using (1)H-NMR and FTIR spectroscopic techniques. Stoichiometry of the complex formed in the 1:8 ratio was evidenced by a Job plot. NMR studies of the above peptide show a marked downfield shift and an increase in (3)J values for NH resonances on complexing with calix[8]arene. The characteristic NOE connectivity between N(i+1)H and C(ialpha)H confirm beta-sheet conformation in the complexed state. Both (1)H-NMR and FTIR results indicate that the alpha-amino group of Leu I is proximal to the macrocycle and is involved in hydrogen bond formation with phenolic hydrogen atom of the calix[8]arene. This suggests that calix[8]arene provides a suitable platform for peptide 1 to self-assemble in a parallel beta-sheet conformation. The nature of calix[8]arene interaction with peptide 1 has been studied using dynamic NMR studies, which concludes that a bifurcated hydrogen bonding interaction exists in the molecular interfaces of the assembly.


Assuntos
Oligopeptídeos/química , Compostos Policíclicos/farmacologia , Calixarenos , Ligação de Hidrogênio , Espectroscopia de Ressonância Magnética , Compostos Policíclicos/química , Conformação Proteica/efeitos dos fármacos , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura , Titulometria
2.
Australas Radiol ; 43(3): 342-5, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10901931

RESUMO

Stereotactic irradiation, either in the form of stereotactic radiosurgery (SRS) or stereotactic radiotherapy (SRT) of brain lesions requires high precision and submillimetre accuracy in the isocentre, the main determinants being gantry and couch rotations. It is thus necessary to evaluate the isocentre variation due to gantry and couch rotations in the particular setup for SRS/SRT. This paper describes variation in the isocentre of a Philips (now Elekta) SL-20 linear accelerator modified for adapting a couch-mounted radiosurgery system. By considering the isocentre as defined by a mechanical index as the standard, the variations in the isocentre of the linear accelerator were independently measured for the gantry and for couch rotations. The variation in the isocentre for gantry rotation was found to be between 0.1 mm and 0.9 mm, conforming to the submillimetre accuracy required for SRS/SRT. However, the isocentre variation due to couch rotation varied considerably, possibly because the couch is of the RAM type. The isocentre variation due to couch rotation is rectified by microadjusting the couch mount at the time of treatment using a laser target localizing frame. It is our conclusion that a modified linear accelerator can be used for performing SRS/SRT after careful and separate evaluation of the isocentre stability due to gantry and couch rotations.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Radiocirurgia/instrumentação , Radioterapia/instrumentação , Desenho de Equipamento , Humanos , Controle de Qualidade , Radiocirurgia/normas , Radioterapia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...