Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 75(6): 2464-72, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26997332

RESUMO

PURPOSE: We explore the advantages of using a double-ring radiofrequency (RF) array and slice orientation to design parallel transmission (pTx) multiband (MB) pulses for simultaneous multislice (SMS) imaging with whole-brain coverage at 7 Tesla (T). METHODS: A double-ring head array with 16 elements split evenly in two rings stacked in the z-direction was modeled and compared with two single-ring arrays consisting of 8 or 16 elements. The array performance was evaluated by designing band-specific pTx MB pulses with local specific absorption rate (SAR) control. The impact of slice orientations was also investigated. RESULTS: The double-ring array consistently and significantly outperformed the other two single-ring arrays, with peak local SAR reduced by up to 40% at a fixed excitation error of 0.024. For all three arrays, exciting sagittal or coronal slices yielded better RF performance than exciting axial or oblique slices. CONCLUSIONS: A double-ring RF array can be used to drastically improve SAR versus excitation fidelity tradeoff for pTx MB pulse design for brain imaging at 7 T; therefore, it is preferable against single-ring RF array designs when pursuing various biomedical applications of pTx SMS imaging. In comparing the stripline arrays, coronal and sagittal slices are more advantageous than axial and oblique slices for pTx MB pulses. Magn Reson Med 75:2464-2472, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Modelos Biológicos , Imagens de Fantasmas
2.
Magn Reson Med ; 59(4): 936-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18383292

RESUMO

This work investigates probe construction materials for their signal contribution to ultrashort echo time spectroscopy and imaging. (1)H, (13)C, and (31)P spectra were obtained at a field strength of 9.4 T for 16 materials considered for use in probe and holder design and construction. Four of the materials were found to be suited for the construction of NMR probes, housing of RF coils, and holders for in vivo experiments.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Manejo de Espécimes/instrumentação , Transdutores , Espectroscopia de Ressonância Magnética/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...