RESUMO
This study evaluated the antimicrobial efficacy of a new intracanal drug based on Pentaclethra macroloba extract, a plant of Amazonian origin, against Enterococcus faecalis using macrodilution test and intratubular evaluation with Confocal Laser Scanning Microscopy (CLSM). The minimum inhibitory concentration (MIC) and the minimum bactericidal concentration (MBC) of the pure extract of Pentaclethra macroloba andits association with calcium hydroxide and ultracall were determined. Then, thirty-three dentin cylinders were prepared and inoculated with E. faecalis, to evaluate the antimicrobial effect of the medications on the dentinal tubules with CLSM. The data was analyzed using the Kruskal-Wallis and Dunn tests. The extract in association with calcium hydroxide showed a lower CBM, and in the intratubular test all tested medications were effective against E. faecalis (P >0.05). The new intracanal drug based on P. macroloba extract has an antimicrobial effect against E. faecalis and further studies are needed for its clinical use.
Assuntos
Anti-Infecciosos , Hidróxido de Cálcio , Hidróxido de Cálcio/farmacologia , Extratos Vegetais/farmacologia , Enterococcus faecalis , Anti-Infecciosos/farmacologiaRESUMO
Asthma is a disorder characterized by airflow obstruction, inflammation, declining airway function, bronchial hyperresponsiveness and tissue remodelling. Probiotics are defined as "live microorganisms that, when administered in adequate amounts, confer a health benefit on the host". The use of probiotics is becoming increasingly studied and recent evidence has suggested that it may provide therapeutic benefits in asthma and other diseases. Lactobacillus delbrueckii UFV-H2b20 fulfils all the requirements to be classified as probiotic. Previous studies have already shown the ability of L. delbrueckii UFV-H2b20 to stimulate the immune system. Our objective was to evaluate the protective effects of L. delbrueckii UFV-H2b20 in experimental allergic asthma. We used a murine model of ovalbumin-induced allergic airway inflammation to mimic allergic asthma. Oral treatment with L. delbrueckii UFV-H2b20 improves respiratory parameters and inhibits the inflammatory response in the lungs by decreasing the numbers of inflammatory monocytes, eosinophils and alveolar macrophages, as well as IgE levels. Treatment increased the IFN-γ/IL-4 cytokine ratio. Levels of IL-10 in the lungs were also increased in treated animals. Our results also showed that the probiotic administration increases the number of CD39+CD73+ T regulatory lymphocytes in the lung, suggesting a role for purinergic signals in the regulation of inflammation promoted by the treatment. Understanding the mechanisms of modulation of the immune system by probiotics could allow the development of probiotic preparations that are safe and have a direct action. Our results suggest that oral administration of L. delbrueckii UFV-H2b20 could be helpful to treat chronic inflammatory airway diseases, such as asthma.
Assuntos
Asma , Lactobacillus delbrueckii , Probióticos , Animais , Camundongos , Asma/terapia , Líquido da Lavagem Broncoalveolar , Contagem de Células , Citocinas/farmacologia , Modelos Animais de Doenças , Inflamação , Interferon gama/metabolismo , Lactobacillus delbrueckii/fisiologia , Pulmão , Camundongos Endogâmicos BALB C , Ovalbumina , Linfócitos T ReguladoresRESUMO
Neutrophils are involved in the early stages of immune responses to pathogens. Here, we investigated the role of neutrophils during the establishment of Leishmania amazonensis infection in BALB/c and C57BL/6 mice. First, we showed an accumulation of neutrophils between 6 and 24 h post-infection, followed by a reduction in neutrophil numbers after 72 h. Next, we depleted neutrophils prior to infection using RB6-8C5 or 1A8 mAb. Neutrophil depletion led to faster lesion development, increased parasite numbers and higher arginase activity during the first week of infection in BALB/c mice, but not in C57BL/6 mice. Increased susceptibility was accompanied by augmented levels of anti-L. amazonensis IgG and increased production of IL-10 and IL-17. Because IL-10 is a mediator of susceptibility to Leishmania infection, we blocked IL-10 signalling in neutrophil-depleted mice using anti-IL-10R. Interestingly, inhibition of IL-10 signalling abrogated the increase in parasite loads observed in neutrophil-depleted mice, suggesting that parasite proliferation is at least partially mediated by IL-10. Additionally, we tested the effect of IL-17 in inflammatory macrophages and observed that IL-17 increased arginase activity and favoured parasite growth. Taken together, our data indicate that neutrophils control parasite numbers and limit lesion development during the first week of infection in BALB/c mice.
Assuntos
Leishmania mexicana/crescimento & desenvolvimento , Leishmania mexicana/imunologia , Leishmaniose Cutânea/imunologia , Leishmaniose Cutânea/parasitologia , Neutrófilos/imunologia , Animais , Anticorpos Antiprotozoários/sangue , Arginase/metabolismo , Feminino , Imunoglobulina G/sangue , Interleucina-10/metabolismo , Interleucina-17/metabolismo , Cinética , Ativação de Macrófagos , Macrófagos/imunologia , Macrófagos/metabolismo , Macrófagos/parasitologia , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Infiltração de Neutrófilos , Carga Parasitária , Linfócitos T Reguladores/imunologiaRESUMO
Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90°. In Group II, fixation was carried out with a four-hole straight plate and four 6mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading.
Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Técnicas de Fixação da Arcada Osseodentária/instrumentação , Mandíbula/cirurgia , Osteotomia Sagital do Ramo Mandibular/métodos , Fenômenos Biomecânicos , Força Compressiva , Análise do Estresse Dentário , Humanos , Modelos Anatômicos , Osteotomia Sagital do Ramo Mandibular/instrumentação , PoliuretanosRESUMO
This study was conducted to evaluate the fatigue strength of Ti-6Al-4V laser-welded joints with several diameters and joint openings. Sixty dumbbell rods were machined in Ti-6Al-4V alloy with central diameters of 1·5, 2·0 and 3·5 mm. The specimens were sectioned and then welded using two joint openings (0·0 and 0·6 mm). The combination of variables created six groups, which when added to the intact groups made a total of nine groups (n = 10). Laser welding was executed as follows: 360 V per 8 ms (1·5 and 2·0 mm) and 380 V per 9 ms (3·5 mm) with focus and frequency regulated to zero. The joints were finished, polished and submitted to radiographic examination to be analysed visually for the presence of porosity. The specimens were then subjected to a mechanical cyclic test, and the number of cycles until failure was recorded. The fracture surface was examined with a scanning electron microscope (SEM). The Kruskal-Wallis test and Dunn test (α = 0·05) indicated that the number of cycles required for fracture was lower for all specimens with joint openings of 0·6 mm, and for 3·5-mm-diameter specimens with joint openings of 0·0 mm. The Spearman correlation coefficient (α = 0·05) indicated that there was a negative correlation between the number of cycles and the presence of porosity. So, laser welding of Ti-6Al-4V structures with a thin diameter provides the best conditions for the juxtaposition of parts. Radiographic examination allows for the detection of internal voids in titanium joints.
Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/métodos , Lasers de Estado Sólido , Titânio/química , Ligas , Óxido de Alumínio/química , Corrosão Dentária/métodos , Implantes Dentários , Polimento Dentário/métodos , Soldagem em Odontologia/instrumentação , Análise do Estresse Dentário/instrumentação , Revestimento de Dentadura , Prótese Parcial Fixa , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Porosidade , Radiografia Interproximal , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de TempoRESUMO
OBJECTIVES: Evaluate the shear bond strength (SBS) and the adhesive remnant index (ARI) of indirect bonded lingual brackets using xenon plasma arc light, light-emitting diode (LED) and conventional quartz-tungsten-halogen light. MATERIAL AND METHODS: Lingual brackets were bonded indirectly to 60 premolars divided to three groups according to the curing light used: Group 1, plasma arc for 6 s; Group 2, LED for 10 s; and Group 3, halogen light for 40 s. After bonding, the specimens were subjected to a shear force until debonding. The debonding pattern was assessed and classified according to the ARI scores. The mean shear bond strengths were accessed by anova followed by the Student-Newman-Keuls test for multiple comparisons. ARI scores were assessed using the chi-square test. RESULTS: The three groups showed significant differences (p < 0.001), with the averages of group 1 < group 2 < group 3. Groups showed no differences regarding ARI scores. CONCLUSION: Bonding lingual brackets indirectly with plasma arc, during 60% of the time used for the LED, produced lower SBS than obtained with the latter. Using LED during 25% of the time of the halogen light produced lower SBS than obtained with the latter. These differences did not influence the debonding pattern and are clinically acceptable according to the literature.
Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Braquetes Ortodônticos , Análise do Estresse Dentário , Humanos , Resistência ao CisalhamentoRESUMO
O alginato ou hidrocolóide irreversível é um dos materiais de moldagem mais aceitos e utilizados na Odontologia. Muitas substâncias como zinco, cádmio, silicato de chumbo e fluoretos foram adicionadas em algumas marcas de alginatos, com o objetivo de melhorar suas propriedades físicas, químicas, mecânicas e se tornaram causa de preocupação no que se refere à toxicidade desses materiais. Em algumas marcas de alginatos relatou-se a presença de fluoretos, cádmio, silicatos de chumbo e zinco potencialmente tóxicos, isoladamente ou em conjunto, consequentemente, cuidados especiais devem ser tomados na preparação desses materiais. É necessário que haja um controle contínuo de metais e substâncias potencialmente tóxicas nos alginatos para se evitar a contaminação dos profissionais da área odontológica e pacientes. Nesta revisão analisou-se o potencial tóxico de alginatos usados em odontologia.
Assuntos
Alginatos/toxicidade , Materiais para Moldagem Odontológica/toxicidade , Cádmio/toxicidade , Chumbo/toxicidade , Fluoretos/toxicidade , Zinco/toxicidadeRESUMO
Alginate is one de materials most employed in practice to make dental impressions. Substances like zinc, cadmium and lead silicate, which are included in several alginate brands with the aim of improving their physical, chemical and mechanical properties, are a source of serious concern regards their toxicity. The most serious chronic effect of oral exposure to cadmium is renal toxicity. Assimilation of lead has deleterious effects on the gastrointestinal tract, hematopoietic system, cardiovascular system, central and peripheral nervous systems, kidneys, immune system, and reproductive system. Chronic oral exposures to zinc have resulted in hypochromic and microcyte anemia in some individuals. The aim of the present study was to measure the cadmium, lead and zinc contents of seven brands of alginate for dental use on sale in Brazil. The samples were weighed and placed in the Teflon cups of a closed-system microwave oven. Aqua regia (4 mL concentrated HCl:HNO3, 3:1 v/v) and hydrofluoric acid (2mL concentrated HF) were added to the samples, which were then subjected to heating. The samples were then cooled to room temperature and diluted to 25 mL in deionized water in a volumetric glass flask. The samples were diluted in duplicate and analyzed against a reagent blank. The analyses were performed in an atomic absorption flame spectrophotometer. Neither lead nor cadmium was detected. Zinc contents ranged from 0.001% to 1.36% by weight. The alginates exhibited low contents of the metals under study and gave no cause for concern regarding toxicity; even so, it is advisable to monitor potentially toxic materials continually and to analyze their plasmatic levels in the professionals working with them
Assuntos
Alginatos/análise , Alginatos/uso terapêutico , Metais Pesados , Odontologia/métodos , Estudos de Avaliação como Assunto , Cádmio/toxicidade , Chumbo/toxicidade , Zinco/toxicidadeRESUMO
Este trabalho teve como proposta analisar quantitativamente o conteúdo de fluoretos nos alginatos para uso odontológico e a liberação de fluoretos de moldes desses alginatos em água milliQ,saliva artificial e ácido clorídrico 0,1 mol/l.Foram investigadas sete marcas de alginatos disponíveis comercialmente no Brasil, sendo analisados dois lotes de cada material.As concentrações de fluoretos nas diferentes amostras foram determinadas por potenciometria direta, utilizando o eletrodo seletivo combinado de fluoreto.Os materiais que apresentaram maiores concentrações médias de fluoreto total foram Hydrogum (7052,87μg/g), Jeltrate Plus (6519,68μg/g) e Orthoprint (6218,18μg/g).Apenas os materiais das marcas Hydrogum e Jeltrate apresentaram diferenças nas concentrações de fluoretos entre os lotes um e dois.Os materiais apresentaram diferenças na liberação de fluoretos dos moldes, cujas maiores concentrações médias foram liberadas pelas marcas Hydrogum e Orthoprint.O meio influenciou na liberação de fluoreto, sendo que na saliva foi menor que na água e nesta foi inferior ao ácido.Os moldes dos materiais que mais liberaram fluoretos nos três meios (saliva, água e ácido) foram os do Hydrogum e Orthoprint.Considerando que as concentrações de fluoretos encontradas nos alginatos são altas e que existem diferentes fontes de exposição aos fluoretos, há necessidade de constante monitoramento dos alginatos para uso odontológico
Assuntos
Alginatos/análise , Fluoretos/análise , Materiais Dentários/toxicidadeRESUMO
The limitation of photoactivation of dual-polymerized resin cements along the margins of metal restorations may adversely affect the mechanical properties of these cements, thus impairing the retention of restorations. The aim of this study was to assess the bond strength of cast metal crowns cemented with three dual-polymerized resin cements, using a chemically-activated resin cement and zinc phosphate as controls. Fifty nickel-chromium alloy crowns were cast and randomly assigned to five groups of equal size. Castings were cemented on their corresponding metal dies with one of the tested luting agents: Scotchbond Resin Cement, Enforce and Panavia F (dual-polymerized resin cements), Cement-It (chemically-activated resin cement) and Zinc Phosphate Cement (zinc phosphate cement). Specimens were stored in distilled water at 37 degrees C for 24 h and then loaded in tension until failure. Panavia F and Zinc Phosphate Cement provided the highest and lowest bond strength means, respectively. Scotchbond Resin Cement, Enforce and Cement-It cements exhibited similar intermediate values, but with statistically significant difference compared to the other materials (P < 0.05). Even with the restriction or absence of light activation, all tested dual-polymerized resin cements produced significantly higher bond strength than did the zinc phosphate cement and yielded similar or better results than the chemically activated cement. It should be pointed out that the findings of this study relate to a test scenario which does not mimic clinical circumstances and that further work is required to identify the clinical significance of the reported tensile bond strength differences between the different luting materials.
Assuntos
Ligas de Cromo , Coroas , Colagem Dentária , Cimentos de Resina , Teste de Materiais , Resistência à TraçãoRESUMO
This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexão Sistemas de Prótese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexão/O-ring; (ii) Conexão/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexão/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexão/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexão/Bar-Clip values were always significantly higher than those of Conexão/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexão/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.