J Mech Behav Biomed Mater ; 34: 208-16, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24607759

RESUMO

The wear performance of two types of crosslinked polyethylene (Marathon™ and XLK™, DePuy Synthes Inc., Warsaw, IN) was evaluated in a pin-on-disc wear tester, a hip wear simulator, and a knee wear simulator. Sodium azide was used as the microbial inhibitor in the calf serum-based lubricant. In the pin-on-disc wear tester, the Marathon wear rate of 5.33±0.54mm(3)/Mc was significantly lower (p=0.002) than the wear rate of 6.43±0.60mm(3)/Mc for XLK. Inversely, the Marathon wear rate of 15.07±1.03mm(3)/Mc from the hip wear simulator was 2.2-times greater than the XLK wear rate of 6.71±1.03mm(3)/Mc from the knee wear simulator. Differences in implant design, conformity, GUR type, and kinematic test conditions were suggested to account for the difference between the wear rates generated in the different types of wear testing apparati. In all wear tests, sodium azide was ineffective at inhibiting microbial growth in the lubricant. Eight different organisms were identified in the lubricant samples from the wear tests, which suggested the necessity of using an alternative, more effective microbial inhibitor. Careful sample preparation and thorough cleaning has shown to improve the consistency of the wear results. The wear rates generated in the hip and knee wear simulators closely reflected the wear behaviour of Marathon and XLK reported in published data that were tested under similar conditions.


Assuntos
Artroplastia de Substituição , Teste de Materiais , Microbiologia , Polietileno/química , Falha de Prótese , Anti-Infecciosos/farmacologia , Azidas/farmacologia
2.
Knee ; 20(6): 388-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23583666

RESUMO

BACKGROUND: The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. METHODS: Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. RESULTS: The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. CONCLUSIONS: The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho/métodos , Ligas de Cromo , Prótese do Joelho , Desenho de Prótese , Idoso , Artroplastia do Joelho/efeitos adversos , Força Compressiva , Bases de Dados Factuais , Feminino , Fêmur , Seguimentos , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Falha de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Resultado do Tratamento , Zircônio