1.
Indian Pacing Electrophysiol J ; 17(3): 72-77, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29073000

RESUMO

BACKGROUND: Cardiac Resynchronization therapy (CRT) remains largely under-used in developing countries owing to the high cost of therapy. In this pilot study, we explore 'optimized' Left Ventricle Only Pacing (LVOP) as a cost effective alternative to cardiac resynchronization therapy in selected patients with heart failure. HYPOTHESIS: In economically poorer patients with heart failure, left bundle branch block (LBBB) and intact AV node conduction, synchronization can be obtained using a dual chamber pacemaker (leads in right atrium and Left ventricle) with the help of 2D strain imaging. METHODS AND RESULTS: 4 patients underwent LVOP for symptomatic heart failure. Post procedure 'optimization' was done using 12 lead electrocardiography and 2D- Strain imaging. Difference between Time to Peak longitudinal strain and Aortic valve Closure (Diff TPL-AC) was calculated for each segment at different AV delays and the AV delay with the smallest Diff TPL-AC was programmed. The mean AV delay that resulted in electrical and mechanical synchrony was 150 ms. After a mean follow up of 6 months, all patients had improved by at least 1 NYHA class. The mean reduction in QRS duration post procedure was -54.5 ± 22.82 ms and the mean improvement in EF was 7 ± 2.75%. CONCLUSION: Optimized LVOP using 2D strain and ECG can be a cost-effective alternative to CRT in patients with LBBB, heart failure and normal AV node conduction.

2.
Indian Pacing Electrophysiol J ; 17(4): 102-107, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29067908

RESUMO

BACKGROUND AND OBJECTIVES: We analyzed Lead II in patients undergoing an Oral Flecainide Challenge test (FCT), to identify any pointers that could predict a positive FCT and thereby help in recognition of latent BS. METHODS: The following parameters in lead II were retrospectively analyzed from the pre-test ECG in 62 patients undergoing FCT for suspected BS: The presence or absence of S waves, S wave amplitude, duration and upslope duration; J point parameters- Early repolarization, QRS notch, and QRS Slur; ST segment parameters-lack of isoelectric ST segment, ST duration and QT interval. RESULTS: 48 had positive FCT (Group-1) while 14 were negative for FCT(Group-2). Lack of an isoelectric ST segment (50% vs 14.29%, p = 0.018) and slurring of QRS (33.33% vs 0%, p = 0.014) was more common in Group-1 than Group-2. Group-1 had shorter ST segment duration (median 81.5 (IQR 64-103.5) vs 110 (IQR 90-132), p = 0.002) and shorter ST: QT ratio (median 0.28 (IQR 0.22-0.35) vs 0.23 (0.18-0.27), p = 0.007). QRS notch/depressed J point (87.5%), QRS slur (100%), and lack of isoelectric ST segment (92.31%) had high sensitivity for predicting an inducible Type 1 Brugada pattern. Combining two parameters- ST: QT ratio<0.24 and lack of isoelectric ST segment-considerably improved the specificity (73.3%), and the positive predictive value of the test to 76%. The results remained accurate when validated in a small prospective cohort. CONCLUSION: Shortened ST segment in Lead II, lack of isoelectric ST segment, slurred QRS and ST/QT ratio <0.24 are predictive of underlying Brugada pattern in baseline ECG.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...