Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 16365, 2019 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-31705009

RESUMO

Research at the Aga Khan University for several years has been directed to find a reliable, low-cost, portable, non-invasive method for identification of coronary artery disease, its location and extent. A new method has been devised to measure the magnitude and direction of cardiac electrical vectors in three perpendicular planes during physical exercise to identify reduction in myocardial excitability as the electrophysiological marker of hypoxia. This report shows that changes in electrical forces due to exercise-induced regional hypoxia serve as indicators of reversible myocardial ischaemia. Changes in the magnitude and direction of vectors at stages of the Bruce protocol were measured in healthy volunteers, and patients undergoing the same exercise protocol for distribution of a radioactive tracer injected intravenously at peak exercise and after recovery (myocardial perfusion scan). Alterations in the magnitude and direction of resultant vectors during exercise were scored to enable analysis. Analysis identified slow progression of myocardial depolarisation as the electrophysiological marker of regional hypoxia relative to physical work. Compared with myocardial perfusion scan the sensitivity and specificity of electrical vectors for identification of ischaemia were 88% and 71%, respectively. Accuracy of ischaemia shown by electrical vectors is being assessed in patients undergoing elective coronary angiography.


Assuntos
Exercício Físico , Ventrículos do Coração/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Complexos Ventriculares Prematuros/fisiopatologia , Potenciais de Ação , Adulto , Idoso , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
2.
Sci Rep ; 7(1): 14649, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29116106

RESUMO

Ischaemia reduces membrane excitability and conduction of myocardial depolarisation. This would alter the synergy of electromotive forces that contribute to a resultant force at any instant. Changes in magnitude and direction of resultant forces are reflected in electrocardiographic signals. Here we show a method for obtaining the coordinates of resultant electrical forces during exercise derived from a bipolar orthogonal lead system for calculation of electrical vectors in three planes. In a trial, analysis of changes in vectors indicated that the extent of reduction in magnitude with exercise was significantly greater in groups of patients categorized by impaired effort tolerance and signs of ischaemia. Measurement of changes in the spectrum of depolarisation vectors during exercise has the potential for non-invasive assessment of myocardial ischaemia. This could be the basis of a portable, low-cost tool for investigation of patients with symptoms suggestive of coronary artery disease.


Assuntos
Potenciais de Ação , Exercício Físico , Ventrículos do Coração/fisiopatologia , Isquemia Miocárdica/fisiopatologia , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Eletrocardiografia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...