1.
Sensors (Basel) ; 22(20)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36298339

RESUMO

The research on sensor fault detection has drawn much interest in recent years. Abrupt, incipient, and intermittent sensor faults can cause the complete blackout of the system if left undetected. In this research, we examined the observer-based residual analysis via index-based approaches for fault detection of multiple sensors in a healthy drive. Seven main indices including the moving mean, average, root mean square, energy, variance, first-order derivative, second-order derivative, and auto-correlation-based index were employed and analyzed for sensor fault diagnosis. In addition, an auxiliary index was computed to differentiate a faulty sensor from a non-faulty one. These index-based methods were utilized for further analysis of sensor fault detection operating under a range of various loads, varying speeds, and fault severity levels. The simulation results on a permanent magnet synchronous motor (PMSM) are provided to demonstrate the pros and cons of various index-based methods for various fault detection scenarios.


Assuntos
Algoritmos , Simulação por Computador
2.
Sci Data ; 4: 170052, 2017 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-28440795

RESUMO

Chest surface motion is of significant importance as it contains information of respiratory and cardiac systems together with the complex coupling between these two systems. Chest surface motion is not only critical in radiotherapy, but also useful in personalized systems for continuous cardiorespiratory monitoring. In this dataset, a multimodal setup is employed to simultaneously acquire cardiorespiratory signals. These signals include high-density trunk surface motion (from 16 distinct locations) with VICON motion capture system, nasal breathing from a thermal sensor, respiratory effort from a strain belt and electrocardiogram in lead-II configuration. This dataset contains 72 trials recorded from 11 participants with a cumulative duration of approximately 215 min under various conditions such as normal breathing, breath-hold, irregular breathing and post-exercise recovery. The presented dataset is not only useful for evaluating prediction algorithms for radiotherapy applications, but can also be employed for the development of techniques to evaluate the cardio-mechanics and hemodynamic parameters of chest surface motion.


Assuntos
Técnicas de Diagnóstico Cardiovascular , Imagem Multimodal , Tórax , Algoritmos , Humanos , Movimento (Física) , Respiração
3.
Sensors (Basel) ; 11(6): 5931-51, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163935

RESUMO

Position sensing with inertial sensors such as accelerometers and gyroscopes usually requires other aided sensors or prior knowledge of motion characteristics to remove position drift resulting from integration of acceleration or velocity so as to obtain accurate position estimation. A method based on analytical integration has previously been developed to obtain accurate position estimate of periodic or quasi-periodic motion from inertial sensors using prior knowledge of the motion but without using aided sensors. In this paper, a new method is proposed which employs linear filtering stage coupled with adaptive filtering stage to remove drift and attenuation. The prior knowledge of the motion the proposed method requires is only approximate band of frequencies of the motion. Existing adaptive filtering methods based on Fourier series such as weighted-frequency Fourier linear combiner (WFLC), and band-limited multiple Fourier linear combiner (BMFLC) are modified to combine with the proposed method. To validate and compare the performance of the proposed method with the method based on analytical integration, simulation study is performed using periodic signals as well as real physiological tremor data, and real-time experiments are conducted using an ADXL-203 accelerometer. Results demonstrate that the performance of the proposed method outperforms the existing analytical integration method.


Assuntos
Monitorização Ambulatorial/instrumentação , Aceleração , Algoritmos , Fenômenos Biomecânicos , Simulação por Computador , Análise de Fourier , Humanos , Modelos Estatísticos , Monitorização Ambulatorial/métodos , Movimento (Física) , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS