Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Neuroeng Rehabil ; 20(1): 149, 2023 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-37936173

RESUMO

Effective communication is especially important in the wearable robots (WRs) community, which encloses a great variety of devices across different application domains, e.g., healthcare, occupational, and consumer. In this paper we present a vocabulary of terms with the aim to create a common understanding of terms and concepts among the different fields of expertise relevant in the WRs community. Our goal is to develop shared documentation that could serve as a reference to facilitate the use of accepted definitions in the field. The presented vocabulary is the result of different focus group discussions among experts in the field. The resulting document was then validated by presenting it to the WR community through an online survey. The results of the survey highlight a strong agreement in terms of acceptance of the vocabulary, its usefulness, and applicability of the proposed definitions as well as an overall appreciation for its purpose and target. This work represents a pilot study providing unique material for the WR community, encouraging the use of shared agreed definitions. The reported version of the vocabulary has been made available as a live document in a github repository, for public commenting and further improvements.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Projetos Piloto , Grupos Focais , Inquéritos e Questionários
2.
J Neuroeng Rehabil ; 20(1): 68, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259115

RESUMO

Exoskeletons are becoming the reference technology for assistance and augmentation of human motor functions in a wide range of application domains. Unfortunately, the exponential growth of this sector has not been accompanied by a rigorous risk assessment (RA) process, which is necessary to identify the major aspects concerning the safety and impact of this new technology on humans. This situation may seriously hamper the market uptake of new products. This paper presents the results of a survey that was circulated to understand how hazards are considered by exoskeleton users, from research and industry perspectives. Our analysis aimed to identify the perceived occurrence and the impact of a sample of generic hazards, as well as to collect suggestions and general opinions from the respondents that can serve as a reference for more targeted RA. Our results identified a list of relevant hazards for exoskeletons. Among them, misalignments and unintended device motion were perceived as key aspects for exoskeletons' safety. This survey aims to represent a first attempt in recording overall feedback from the community and contribute to future RAs and the identification of better mitigation strategies in the field.


Assuntos
Exoesqueleto Energizado , Traumatismos da Medula Espinal , Humanos , Inquéritos e Questionários
3.
Appl Ergon ; 98: 103582, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34600307

RESUMO

OBJECTIVES: To provide an overview of protocols assessing the effect of occupational exoskeletons on users and to formulate recommendations towards a literature-based assessment framework to benchmark the effect of occupational exoskeletons on the user. METHODS: PubMed (MEDLINE), Web of Science database and Scopus were searched (March 2, 2021). Studies were included if they investigated the effect of one or more occupational exoskeletons on the user. RESULTS: In total, 139 eligible studies were identified, encompassing 33, 25 and 18 unique back, shoulder and other exoskeletons, respectively. Device validation was most frequently conducted using controlled tasks while collecting muscle activity and biomechanical data. As the exoskeleton concept matures, tasks became more applied and the experimental design more representative. With that change towards realistic testing environments came a trade-off with experimental control, and user experience data became more valuable. DISCUSSION: This evidence mapping systematic review reveals that the assessment of occupational exoskeletons is a dynamic process, and provides literature-based assessment recommendations. The homogeneity and repeatability of future exoskeleton assessment experiments will increase following these recommendations. The current review recognises the value of variability in evaluation protocols in order to obtain an overall overview of the effect of exoskeletons on the users, but the presented framework strives to facilitate benchmarking the effect of occupational exoskeletons on the users across this variety of assessment protocols.


Assuntos
Benchmarking , Exoesqueleto Energizado , Humanos , Ombro
5.
Wearable Technol ; 2: e11, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-38486625

RESUMO

The large-scale adoption of occupational exoskeletons (OEs) will only happen if clear evidence of effectiveness of the devices is available. Performing product-specific field validation studies would allow the stakeholders and decision-makers (e.g., employers, ergonomists, health, and safety departments) to assess OEs' effectiveness in their specific work contexts and with experienced workers, who could further provide useful insights on practical issues related to exoskeleton daily use. This paper reviews present-day scientific methods for assessing the effectiveness of OEs in laboratory and field studies, and presents the vision of the authors on a roadmap that could lead to large-scale adoption of this technology. The analysis of the state-of-the-art shows methodological differences between laboratory and field studies. While the former are more extensively reported in scientific papers, they exhibit limited generalizability of the findings to real-world scenarios. On the contrary, field studies are limited in sample sizes and frequently focused only on subjective metrics. We propose a roadmap to promote large-scale knowledge-based adoption of OEs. It details that the analysis of the costs and benefits of this technology should be communicated to all stakeholders to facilitate informed decision making, so that each stakeholder can develop their specific role regarding this innovation. Large-scale field studies can help identify and monitor the possible side-effects related to exoskeleton use in real work situations, as well as provide a comprehensive scientific knowledge base to support the revision of ergonomics risk-assessment methods, safety standards and regulations, and the definition of guidelines and practices for the selection and use of OEs.

6.
Wearable Technol ; 2: e14, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-38486636

RESUMO

The science and technology of wearable robots are steadily advancing, and the use of such robots in our everyday life appears to be within reach. Nevertheless, widespread adoption of wearable robots should not be taken for granted, especially since many recent attempts to bring them to real-life applications resulted in mixed outcomes. The aim of this article is to address the current challenges that are limiting the application and wider adoption of wearable robots that are typically worn over the human body. We categorized the challenges into mechanical layout, actuation, sensing, body interface, control, human-robot interfacing and coadaptation, and benchmarking. For each category, we discuss specific challenges and the rationale for why solving them is important, followed by an overview of relevant recent works. We conclude with an opinion that summarizes possible solutions that could contribute to the wider adoption of wearable robots.

7.
Hum Factors ; 62(3): 351-364, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31928418

RESUMO

OBJECTIVE: To explore user-centered design methods currently implemented during development of lower limb wearable robots and how they are utilized during different stages of product development. BACKGROUND: Currently, there appears to be a lack of standardized frameworks for evaluation methods and design requirements to implement effective user-centered design for safe and effective clinical or ergonomic system application. METHOD: Responses from a total of 191 experts working in the field of lower limb exoskeletons were analyzed in this exploratory survey. Descriptive statistics were used to present responses and measures of frequency, and chi-square tests were used to contrast the answers of respondents who identified as clinicians versus engineers. RESULTS: A vast majority of respondents involve users in their development, in particular at the initial and iterative stages, although some differences were found between disciplines. A variety of methods and metrics are used to capture feedback from users and test devices, and although valuable, some methods used may not be based on validated measures. Guidelines regarding tests on safety of exoskeletons also lack standardization. CONCLUSION: There seems to be a consensus among experts regarding the importance of a user-centered approach in exoskeleton development; however, standardized frameworks with regard to appropriate testing methods and design approaches are lacking. Such frameworks should consider an interdisciplinary focus on the needs and safety of the intended user during each iteration of the process. APPLICATION: This exploratory study provides an overview of current practice among engineers and clinicians regarding the user-centered design of exoskeletons. Limitations and recommendations for future directions are identified.


Assuntos
Exoesqueleto Energizado , Extremidade Inferior/fisiologia , Robótica , Participação dos Interessados , Design Centrado no Usuário , Humanos , Dispositivos Eletrônicos Vestíveis
8.
Front Robot AI ; 7: 561774, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33501326

RESUMO

Wearable robots (WRs) are increasingly moving out of the labs toward real-world applications. In order for WRs to be effectively and widely adopted by end-users, a common benchmarking framework needs to be established. In this article, we outline the perspectives that in our opinion are the main determinants of this endeavor, and exemplify the complex landscape into three areas. The first perspective is related to quantifying the technical performance of the device and the physical impact of the device on the user. The second one refers to the understanding of the user's perceptual, emotional, and cognitive experience of (and with) the technology. The third one proposes a strategic path for a global benchmarking methodology, composed by reproducible experimental procedures representing real-life conditions. We hope that this paper can enable developers, researchers, clinicians and end-users to efficiently identify the most promising directions for validating their technology and drive future research efforts in the short and medium term.

10.
IEEE Int Conf Rehabil Robot ; 2019: 721-726, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31374716

RESUMO

In EU-funded BALANCE project, developing a stability index which can be employed to estimate actual state of balance of both healthy and neurologically impaired humans' walking in exoskeleton was one of scientific tasks. In the task, Centroidal Momentum (CM), referring to linear and angular momenta at Center of Mass (CoM), has raised as a potential index for such purpose. While our past studies have presented analysis results of CM in offline and online (real time) manners for walking of healthy human and stroke patients, in this study, we present real time computation of CM in exoskeleton-supported walking, specifically with healthy subjects. Experimental setup consists of LOPES II, a treadmill-based robotic gait training exoskeleton for lower limbs rehabilitation developed by Twente University, and commercially available IMUs (Inertial Measurement Units)-based full body motion capture suits from Xsens. CM was computed and demonstrated in two walking conditions: unperturbed walking and walking with unexpected pelvic perturbations in lateral direction. While electromagnetic fields (EMF) from LOPES II exoskeleton affected signals of IMUs in the motion capture suit, the results show the potential applicability of the CM as a sort of stability index for human walking in the exoskeleton.


Assuntos
Exoesqueleto Energizado , Extremidade Inferior/fisiopatologia , Caminhada/fisiologia , Humanos , Masculino , Movimento (Física) , Reabilitação do Acidente Vascular Cerebral , Fatores de Tempo
11.
J Neuroeng Rehabil ; 14(1): 80, 2017 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-28806995

RESUMO

Clinically useful and efficient assessment of balance during standing and walking is especially challenging in patients with neurological disorders. However, rehabilitation robots could facilitate assessment procedures and improve their clinical value. We present a short overview of balance assessment in clinical practice and in posturography. Based on this overview, we evaluate the potential use of robotic tools for such assessment. The novelty and assumed main benefits of using robots for assessment are their ability to assess 'severely affected' patients by providing assistance-as-needed, as well as to provide consistent perturbations during standing and walking while measuring the patient's reactions. We provide a classification of robotic devices on three aspects relevant to their potential application for balance assessment: 1) how the device interacts with the body, 2) in what sense the device is mobile, and 3) on what surface the person stands or walks when using the device. As examples, nine types of robotic devices are described, classified and evaluated for their suitability for balance assessment. Two example cases of robotic assessments based on perturbations during walking are presented. We conclude that robotic devices are promising and can become useful and relevant tools for assessment of balance in patients with neurological disorders, both in research and in clinical use. Robotic assessment holds the promise to provide increasingly detailed assessment that allows to individually tailor rehabilitation training, which may eventually improve training effectiveness.


Assuntos
Doenças do Sistema Nervoso/diagnóstico , Modalidades de Fisioterapia/instrumentação , Equilíbrio Postural , Robótica/métodos , Caminhada , Humanos , Masculino
12.
Disabil Rehabil Assist Technol ; 12(5): 526-534, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27052929

RESUMO

PURPOSE: We present a novel wheelchair posture support device (WPSD) and its clinical validation. The device was developed in order to assure correct sitting posture and to reduce the time spent by caregivers for re-positioning of hospitalized, wheelchair-bound, post-acute stroke patients. METHOD: The device was validated with 16 subjects during a period of 5 days in which use of the device was compared with regular care practice. RESULTS: The device was used for the five consecutive days in 69% of patients, while for 6% it was not suitable; 25% did not complete the 5 days for reasons unrelated to the device. Caregivers needed to re-position the patients that used the device for the full 5 days (n = 11) on an average 52% less often when using the device, as compared to regular practice. Furthermore, the device was rated as usable and functional by the caregivers while significantly reducing perception of trunk and shoulder pain in patients during its use. CONCLUSIONS: The newly designed WPSD is a valuable system for the improvement of medical assistance to wheelchair-bound post-stroke patients by reducing pain and number of re-positioning manoeuvres. The WPSD might be applicable to any group of patients who need posture control in either wheelchair or common chair with arms support. IMPLICATIONS FOR REHABILITATION Advanced supports and cushions that can be shaped to individual needs, may help assure correct sitting posture in wheelchair-bound post-acute stroke patients. Advanced supports and cushions that can be shaped to individual needs, may reduce the number of times a caregiver has to re-position a hospitalized wheelchair-bound post-acute stroke patient on overall average by 52%. Advanced personalized supports and cushions may improve sitting comfort and reduce pain complaints for post-acute hospitalized stroke patients using a wheelchair.


Assuntos
Postura , Reabilitação do Acidente Vascular Cerebral/instrumentação , Cadeiras de Rodas , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Pessoas com Deficiência , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentação e Reposicionamento de Pacientes , Segurança do Paciente , Úlcera por Pressão/prevenção & controle , Fatores de Tempo
13.
J Rehabil Res Dev ; 48(4): 317-33, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21674386

RESUMO

Numerous haptic devices have been developed for upper-limb neurorehabilitation, but their widespread use has been largely impeded because of complexity and cost. Here, we describe a variable structure pantograph mechanism combined with a spring suspension system that produces a versatile rehabilitation robot, called Universal Haptic Pantograph, for movement training of the shoulder, elbow, and wrist. The variable structure is a 5-degree-of-freedom (DOF) mechanism composed of 7 joints, 11 joint axes, and 3 configurable joint locks that reduce the number of system DOFs to between 0 and 3. The resulting device has eight operational modes: Arm, Wrist, ISO (isometric) 1, ISO 2, Reach, Lift 1, Lift 2, and Steer. The combination of available work spaces (reachable areas) shows a high suitability for movement training of most upper-limb activities of daily living. The mechanism, driven by series elastic actuators, performs similarly in all operational modes, with a single control scheme and set of gains. Thus, a single device with minimal setup changes can be used to treat a variety of upper-limb impairments that commonly afflict veterans with stroke, traumatic brain injury, or other direct trauma to the arm. With appropriately selected design parameters, the developed multimode haptic device significantly reduces the costs of robotic hardware for full-arm rehabilitation while performing similarly to that of single-mode haptic devices. We conducted case studies with three patients with stroke who underwent clinical training using the developed mechanism in Arm, Wrist, and/or Reach operational modes. We assessed outcomes using Fugl-Meyer Motor Assessment and Wolf Motor Function Test scores showing that upper-limb ability improved significantly following training sessions.


Assuntos
Paresia/reabilitação , Robótica/instrumentação , Reabilitação do Acidente Vascular Cerebral , Atividades Cotidianas , Fenômenos Biomecânicos , Paresia/etiologia , Robótica/economia , Acidente Vascular Cerebral/complicações , Extremidade Superior
14.
IEEE Int Conf Rehabil Robot ; 2011: 5975350, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22275554

RESUMO

In robotic rehabilitation, the way of attaching the robotic device to the users' limb constitutes a crucial element of product quality, particularly for assuring good fitting, comfort, accuracy, usability, and safety. In this article, we present a new technological concept - 'Variable Stiffness Structure' - allowing for an improvement of these aspects in the 'robotic device to limb' - connection by offering a compound of materials that are together able to switch from a flexible textile-like state to a more rigid state by applying negative pressure. The paper describes the concept and the basic behaviour of the material, based on experiments.


Assuntos
Extremidades/fisiologia , Robótica/instrumentação , Robótica/métodos , Humanos
15.
Artigo em Inglês | MEDLINE | ID: mdl-22254744

RESUMO

ArmAssist is a wireless robot for post stroke upper limb rehabilitation. Knowing the position of the arm is essential for any rehabilitation device. In this paper, we describe a method based on an artificial landmark navigation system. The navigation system uses three optical mouse sensors. This enables the building of a cheap but reliable position sensor. Two of the sensors are the data source for odometry calculations, and the third optical mouse sensor takes very low resolution pictures of a custom designed mat. These pictures are processed by an optical symbol recognition algorithm which will estimate the orientation of the robot and recognize the landmarks placed on the mat. The data fusion strategy is described to detect the misclassifications of the landmarks in order to fuse only reliable information. The orientation given by the optical symbol recognition (OSR) algorithm is used to improve significantly the odometry and the recognition of the landmarks is used to reference the odometry to a absolute coordinate system. The system was tested using a 3D motion capture system. With the actual mat configuration, in a field of motion of 710 × 450 mm, the maximum error in position estimation was 49.61 mm with an average error of 36.70 ± 22.50 mm. The average test duration was 36.5 seconds and the average path length was 4173 mm.


Assuntos
Periféricos de Computador , Dispositivos Ópticos , Reabilitação/instrumentação , Robótica/instrumentação , Terapia Assistida por Computador/instrumentação , Transdutores , Algoritmos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
IEEE Trans Neural Syst Rehabil Eng ; 16(4): 360-370, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18713676

RESUMO

"Assist as needed" control algorithms promote activity of patients during robotic gait training. Implementing these requires a free walking mode of a device, as unassisted motions should not be hindered. The goal of this study was to assess the normality of walking in the free walking mode of the LOPES gait trainer, an 8 degrees-of-freedom lightweight impedance controlled exoskeleton. Kinematics, gait parameters and muscle activity of walking in a free walking mode in the device were compared with those of walking freely on a treadmill. Average values and variability of the spatio-temporal gait variables showed no or small (relative to cycle-to-cycle variability) changes and the kinematics showed a significant and relevant decrease in knee angle range only. Muscles involved in push off showed a small decrease, whereas muscles involved in acceleration and deceleration of the swing leg showed an increase of their activity. Timing of the activity was mainly unaffected. Most of the observed differences could be ascribed to the inertia of the exoskeleton. Overall, walking with the LOPES resembled free walking, although this required several adaptations in muscle activity. These adaptations are such that we expect that Assist as Needed training can be implemented in LOPES.

17.
Gait Posture ; 28(1): 157-63, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18207406

RESUMO

In assistive devices for neuro-rehabilitation, natural human motions are partly restricted by the device. This may affect the normality of walking during training. This research determines effects on gait of fixating the pelvis translations in the horizontal plane during treadmill walking. Direct effects on the motion of the pelvis and external forces acting on the pelvis were measured. Several gait descriptors (step parameters, trunk angles and a ground reaction force parameter) were defined and measured to indicate changes. We observed the effect of the pelvis fixation on these parameters while varying gait velocity (0.35, 0.60 and 0.90 m/s). It was shown that the fixation caused a reduction of step width by 33%, and an increase of step length of 19%. Sagittal and coronal trunk rotations changed with +68% and -54% respectively. The fixation also significantly changed the effect of speed on most descriptors. It can therefore be concluded that a fixation of the pelvis severely affects gait dynamics and that it should be avoided if natural walking should be possible during training.


Assuntos
Marcha/fisiologia , Pelve/fisiologia , Adulto , Teste de Esforço , Humanos , Masculino , Caminhada/fisiologia
18.
IEEE Trans Neural Syst Rehabil Eng ; 15(3): 379-86, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17894270

RESUMO

This paper introduces a newly developed gait rehabilitation device. The device, called LOPES, combines a freely translatable and 2-D-actuated pelvis segment with a leg exoskeleton containing three actuated rotational joints: two at the hip and one at the knee. The joints are impedance controlled to allow bidirectional mechanical interaction between the robot and the training subject. Evaluation measurements show that the device allows both a "patient-in-charge" and "robot-in-charge" mode, in which the robot is controlled either to follow or to guide a patient, respectively. Electromyography (EMG) measurements (one subject) on eight important leg muscles, show that free walking in the device strongly resembles free treadmill walking; an indication that the device can offer task-specific gait training. The possibilities and limitations to using the device as gait measurement tool are also shown at the moment position measurements are not accurate enough for inverse-dynamical gait analysis.


Assuntos
Teste de Esforço/instrumentação , Transtornos Neurológicos da Marcha/reabilitação , Sistemas Homem-Máquina , Robótica/instrumentação , Terapia Assistida por Computador/instrumentação , Interface Usuário-Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Esforço/métodos , Humanos , Robótica/métodos , Terapia Assistida por Computador/métodos
19.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 189-93, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946801

RESUMO

We have designed and built a lower extremity powered exo-skeleton (LOPES) for the training of post-stroke patients. This paper describes the philosophy behind the design of LOPES, motivates the choices that have been made and gives some exemplary results of the ranges of mechanical impedances that can be achieved.


Assuntos
Transtornos Neurológicos da Marcha/fisiopatologia , Transtornos Neurológicos da Marcha/reabilitação , Sistemas Homem-Máquina , Modalidades de Fisioterapia/instrumentação , Robótica/instrumentação , Terapia Assistida por Computador/instrumentação , Adulto , Desenho Assistido por Computador , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Humanos , Masculino , Robótica/métodos , Terapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...