1.
Phys Med ; 24(3): 149-58, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18289906

RESUMO

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and nominal slice width (2-32 mm). Linear fits of the CTDI values for mAs show for the smallest phantom diameter an increase in CTDI of 60% for both TLD and polymer gel dosimeters. A similar increase in CTDI of 50% at 100 kVp and 100% for 135 kVp was also noted. It was also shown that slice width variation measured with either polymer gel or TLD was greatest with the smallest slice widths. In summary, it was found that polymer gels can be used as an alternative dosimeter to TLD for the determination of SWDP and subsequent CTDI calculations.


Assuntos
Polímeros , Doses de Radiação , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Géis , Imagens de Fantasmas , Fatores de Tempo
2.
Phys Med Biol ; 50(16): 3875-88, 2005 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16077233

RESUMO

Investigation of the normoxic PAGAT polymer gel dosimeter has been undertaken. The concentrations of the chemical components of the gel were varied and its response to ionizing radiation evaluated. Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N, N'-methylene-bis-acrylamide (bis), 4.5% acrylamide (AA), 5% gelatine, 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), 0.01 mM hydroquinone (HQ) and 86% H2O. The optimal post-manufacture irradiation and post-irradiation imaging times were both determined to be 12 h. The R2-dose response was linear up to 7 Gy with R2-dose sensitivities of (0.183 +/- 0.005) s(-1) Gy(-1), (0.182 +/- 0.005) s(-1) Gy(-1) and (0.192 +/- 0.005) s(-1) Gy(-1) when imaged at 12 h, 7 days and 24 days post-irradiation, respectively. The R2-dose sensitivities were within the range of previously published values for the hypoxic PAG formulations. For the imaging parameters used in this study the optimum dose resolution was achieved for low doses. The normalized R2 edge response showed a high degree of spatial stability over a 24 day period. This study has shown that the normoxic PAGAT polymer gel has the properties of a dosimetric tool, which can be used in clinical radiotherapy. The PAGAT polymer gel has been shown to have similar qualities to the PAG polymer gel, while offering the significant advantage of simplification of the manufacturing procedure.


Assuntos
Resinas Acrílicas/química , Imageamento por Ressonância Magnética/métodos , Compostos Organofosforados/química , Radiometria/instrumentação , Radiometria/métodos , Acrilamida/farmacologia , Acrilamidas/farmacologia , Relação Dose-Resposta à Radiação , Gelatina/farmacologia , Humanos , Processamento de Imagem Assistida por Computador , Polímeros/química , Fatores de Tempo
3.
Australas Phys Eng Sci Med ; 28(2): 105-10, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16060316

RESUMO

The effect of vacuum pumping on the dose response of the MAGAS polymer gel dosimeter has been investigated. A delay of several days post-manufacture before irradiation was previously necessary due to the slow oxygen scavenging of ascorbic acid. The MAGAS polymer gel dosimeter was vacuum pumped before gelation to remove dissolved oxygen. The MAGAS polymer gel dosimeter was poured into glass screw-top vials, which were irradiated at various times, post-manufacture to a range of doses. Magnetic resonance imaging techniques were used to determine the R2-dose response and R2-dose sensitivity of the MAGAS polymer gel. The results were compared with a control batch of MAGAS polymer gel that was not vacuum pumped. It was shown that vacuum pumping on the MAGAS polymer gel solution immediately prior to sealing in glass screw-top vials initially increases the R2-dose response and R2-dose sensitivity of the dosimeter. An increase in the R2-dose response and R2-dose sensitivity was observed with increasing time between manufacture and irradiation. Over the range of post-manufacture irradiation times investigated, the greatest R2-dose response and R2-dose sensitivity occurred at 96 hours.


Assuntos
Metacrilatos/química , Metacrilatos/efeitos da radiação , Oxigênio/química , Radiometria/instrumentação , Relação Dose-Resposta à Radiação , Análise de Falha de Equipamento , Géis/química , Géis/efeitos da radiação , Polímeros/química , Polímeros/efeitos da radiação , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vácuo
4.
Med Phys ; 32(4): 1047-53, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15895589

RESUMO

The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m(-3)) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.


Assuntos
Oxigênio/química , Polímeros/química , Radiometria/instrumentação , Radiometria/métodos , Ácido Ascórbico/química , Cobre/química , Elétrons , Metacrilatos/química , Modelos Estatísticos , Método de Monte Carlo , Compostos Organofosforados/química , Fótons , Probabilidade , Água/química
5.
Phys Med Biol ; 49(20): N353-61, 2004 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-15566179

RESUMO

The change in linear attenuation coefficient with absorbed dose has been investigated for aqueous polyacrylamide, gelatine and tetrakis (PAGAT) and aqueous methacrylic acid, gelatine and tetrakis (MAGAT) normoxic polymer gel dosimeters using tetrakis (hydroxy methyl) phosphonium chloride as the antioxidant. The measured linear attenuation coefficient increased linearly with absorbed dose up to 15 Gy for PAGAT gels and 10 Gy for MAGAT gels. Computerized tomography (CT) numbers or Hounsfield units (H) were calculated from the linear attenuation coefficients and compared with values obtained using a CT scanner. Both calculated and measured CT numbers followed a similar pattern when fitted with a biexponential curve. The CT numbers obtained from linear attenuation measurements were found to be greater than that obtained with the CT scanner for both PAGAT and MAGAT polymer gels. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters measured on a CT scanner were calculated to be (0.85 +/- 0.08) H Gy(-1) and (0.31 +/- 0.03) H Gy(-1), respectively. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters from attenuation measurements were found to be (1.10 +/- 0.66) H Gy(-1) and (0.34 +/- 0.01) H Gy(-1), respectively.


Assuntos
Resinas Acrílicas/efeitos da radiação , Análise de Falha de Equipamento , Géis/efeitos da radiação , Ácidos Polimetacrílicos/efeitos da radiação , Radiometria/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Raios X