Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38892771

RESUMO

Introduction: The aim of this paper is to propose a sequential deployment technique for the E-nside off-the-shelf endograft that could potentially enhance target visceral vessel (TVV) cannulation and overstenting in narrow aortic anatomies. Methods: All data regarding patients consecutively treated in two aortic centers with the E-nside graft employing the partial deployment technique were included in the study cohort and analyzed. To execute the procedure with partial endograft deployment, the device should be prepared before insertion by advancing, under fluoroscopy, all four dedicated 400 cm long 0.018″ non-hydrophilic guidewires until their proximal ends reach the cranial graft's edge. Anticipating this guidewire placement prevents the inability to do so once the endograft is partially released, avoiding potentially increased friction inside the constricted pre-loaded microchannels. The endograft is then advanced and deployed in the standard fashion, stopping just after the inner branch outlets are fully expanded. Tip capture is released, and the proximal end of the device is opened. Visceral vessel bridging is completed from an upper access in the desired sequence, and the graft is fully released after revascularizing one or more arteries. Preventing the distal edge of the graft from fully expanding improves visceral vessel cannulation and bridging component advancement, especially when dealing with restricted lumina. Results: A total of 26 patients were treated during the period December 2019-March 2024 with the described approach. Procedure was performed in urgent settings in 14/26 cases. The available lumen was narrower than 24 mm at the origin of at least one target vessel in 11 out of 26 cases performed (42.3%). Technical success was obtained in 24 out of 26 cases (92.3%), with failures being due to TVVs loss. No intraoperative death or surgical conversion was recorded, and no early reintervention was needed in the perioperative period. Clinical success at 30 days was therefore 80.7%. Conclusions: The described technique could be considered effective in saving space outside of the graft, allowing for safe navigation and target vessel cannulation in narrow visceral aortas, similar to what has already been reported for outer-branched endografts.

2.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830024

RESUMO

This case report presents a 49-year-old male with multiple intercostal and lumbar aneurysms of the thoraco-abdominal aorta, complicating a history of aortic surgeries and comorbidities. Following emergent surgical repair of a ruptured lumbar aneurysm, a multidisciplinary team opted for staged interventions, mitigating risks and optimizing outcomes. Treatment stages involved surgical ligation and endovascular embolization, aiming to minimize complications, particularly spinal cord ischaemia. This case underscores the challenges of managing complex and rare aortic pathology, highlighting the importance of multidisciplinary care and close follow-up to mitigate risks.


Assuntos
Aneurisma da Aorta Torácica , Humanos , Masculino , Pessoa de Meia-Idade , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Embolização Terapêutica/métodos
3.
Ann Vasc Surg ; 108: 84-91, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942373

RESUMO

BACKGROUND: Our objective is twofold: determining if simulation allows residents to reach proficient surgeons' performance concerning fundamental technical skills of endovascular surgery (FEVS) while investigating effects of the program on surgeons' stress. METHODS: Using a FEVS training simulator, 8 endovascular FEVS were performed by vascular surgery residents (simulator-naive or simulator-experienced residents [SER]) and seniors. Total time needed to complete the 8 tasks, called total completion time (TCT), was the main evaluation criterion. Analgesia Nociception Index (ANI) was monitored during simulation. Likert scale questionnaire was filled out after each simulation. RESULTS: For each task, TCT was significantly lower for SER and seniors than simulator-naive residents (P = 0.0163). After only 5 simulations, SER were able to reach and even exceed the seniors' level in terms of TCT, with a median time of 10.8 min for SER and 11.9 min for seniors, and wire's movements with a median distance during cannulation of 4.44 m for SER and 4.17 m for seniors. Seniors remained better than SER in terms of precise wire manipulation (wire movement after cannulation), 4.17 m against 4.44 m (3.72-5.96), respectively. Based on the Likert scale stress analysis, seniors felt less stressed than both residents' groups (P = 0.0618). Seniors' initial ANI and mean ANI over the session were significantly lower than those of the residents, P = 0.0358 and P = 0.0250, respectively. CONCLUSIONS: We showed that 5 simulation sessions allowed residents to reach experienced surgeons' capacities on FEVS concerning TCT. Subjectively, seniors felt less stressed than residents, contrary to the results of our objective measures of stress.

4.
Front Med Technol ; 6: 1384008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756327

RESUMO

Cardiovascular diseases remain a global health challenge, prompting continuous innovation in medical technology, particularly in Cardiovascular MedTech. This article provides a comprehensive exploration of the transformative landscape of Cardiovascular MedTech in the 21st century, focusing on interventions. The escalating prevalence of cardiovascular diseases and the demand for personalized care drive the evolving landscape, with technologies like wearables and AI reshaping patient-centric healthcare. Wearable devices offer real-time monitoring, enhancing procedural precision and patient outcomes. AI facilitates risk assessment and personalized treatment strategies, revolutionizing intervention precision. Minimally invasive procedures, aided by robotics and novel materials, minimize patient impact and improve outcomes. 3D printing enables patient-specific implants, while regenerative medicine promises cardiac regeneration. Augmented reality headsets empower surgeons during procedures, enhancing precision and awareness. Novel materials and radiation reduction techniques further optimize interventions, prioritizing patient safety. Data security measures ensure patient privacy in the era of connected healthcare. Modern technologies enhance traditional surgeries, refining outcomes. The integration of these innovations promises to shape a healthier future for cardiovascular procedures, emphasizing collaboration and research to maximize their transformative potential.

5.
J Clin Med ; 13(6)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38541762

RESUMO

(1) Background: Type 2 diabetes is a major cause of incidences and the progression of peripheral artery disease (PAD). Bone marrow edema (BME) is an important finding suggestive of underlying bone inflammation in non-traumatic diabetic patients with PAD. Our aim was to evaluate the presence, severity, and clinical implications of BME detected by virtual non-calcium application (VNCa) of dual-energy CT angiography (DE-CTA). (2) Methods: A consecutive series of 76 diabetic patients (55 men; mean age 71.6 ± 11.2 yrs) submitted to lower limb DE-CTA for PAD evaluation and revascularization planning, which were retrospectively analyzed. VNCa images were independently and blindly revised for the presence, location, and severity of BME by two radiologists with 10 years of experience. BME and non-BME groups were evaluated in terms of PAD clinical severity and 6-month secondary major amputation rate. (3) Results: BME was present in 17 (22%) cases, while 59 (78%) patients were non-BME. The BME group showed a significantly higher incidence of major amputation (p < 0.001) and a significantly higher number of patients with advanced clinical stages of PAD compared to the non-BME group (p = 0.024). (4) Conclusions: Lower limb DE-CTA with VNCa application is a useful tool in the detection of BME in diabetic patients with PAD, simultaneously enabling the evaluation of the severity and location of the arterial disease for revascularization planning. BME presence could be a marker of clinically severe PAD and a possible risk factor for revascularization failure.

6.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36579884

RESUMO

In patients with extensive thoraco-abdominal aortic disease, staged hybrid repair involving open total aortic arch replacement and endovascular thoraco-abdominal aorta repair with branched stent graft has emerged as a valuable treatment option. However, total arch replacement with the available branched vascular grafts often results in acute angulation between the reimplanted vessels and the aortic arch hampering antegrade catheterization of the thoraco-abdominal aorta during the second endovascular stage. Here, we present our 'switch technique' for arch vessels' reimplantation to facilitate antegrade aortic catheterization of the thoraco-abdominal aorta and visceral vessels.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/cirurgia , Aorta Abdominal , Implante de Prótese Vascular/métodos , Prótese Vascular , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Stents , Resultado do Tratamento , Procedimentos Endovasculares/métodos
7.
Front Surg ; 9: 955932, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36303855

RESUMO

Background: Giant angiomyolipoma is usually associated with genetic syndromes and complications (spontaneous rupture and bleeding, hematuria, hypertension) and mass-related symptoms (flank and abdominal pain). Case presentation: We present a case of a 20-year-old woman suffering from tuberous sclerosis who was referred to our hospital with a giant angiomyolipoma causing abdominal pain. A contrast-enhanced computed tomography showed a left angiomyolipoma, measuring 28 cm × 17 cm × 27 cm. After a multidisciplinary team discussion, the patient was submitted for a nephrectomy. Percutaneous temporary occlusion of the main renal artery was achieved through an endovascular balloon catheter. Through the balloon catheter guidewire, 2,500 IU of heparin was infused to reduce the risk of tumor vein thrombosis and venous embolism. This allowed a safe kidney manipulation through a left thoracoabdominal approach. The postoperative course was uneventful. Pathology showed a 40 cm × 30 cm × 9 cm and 10 kg AML. One year after surgery, the patient is on follow-up, and her estimated glomerular filtration is 120.5 ml/min/1.73 m2. Conclusion: The present case showed that the endovascular control of the main renal artery could be considered a useful approach to safely managing huge renal masses when renal hilar control is expected to be very difficult.

8.
EJVES Vasc Forum ; 55: 5-8, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35252939

RESUMO

OBJECTIVE: To ascertain whether simulated endovascular procedures are comparable to real life operating room (OR) procedures, particularly with regard to irradiation time. METHODS: This was a retrospective study comparing simulation with clinical data. Fluoroscopy time and overall operation time were compared between simulated abdominal aortic endovascular repair (EVAR) and iliac procedures that were performed, respectively, from 2016 to 2019 and from 2015 to 2019, and clinical EVAR and iliac procedures performed in the OR between January 2018 and November 2021. RESULTS: Within the defined periods, 171 simulated procedures (91 EVAR, 80 iliac) and 199 clinical procedures (111 EVAR, 88 iliac) were performed. For both EVAR and iliac procedures, median total procedure time was much longer during real surgery (p < .001). However, median total fluoroscopy time remained the same, whether the procedure was real surgery or performed on the simulator, for iliac procedures (8.47 minutes in the OR, 8.35 minutes on the simulator, p = .61) and for EVAR procedures (14.80 minutes in the OR, 15.00 minutes on the simulator p = .474). CONCLUSION: Simulated endovascular procedures are comparable with real life OR procedures, particularly with regard to irradiation time when integrated in a dedicated curriculum.

9.
J Thorac Cardiovasc Surg ; 164(5): 1412-1420, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-33419559

RESUMO

OBJECTIVE: Standard surgical repair of acute type A aortic dissection is associated with high mortality rates, especially in high-risk patients. In an attempt to improve survival in frail patients, we evaluated the outcomes after ascending aorta wrapping in a high-risk patient cohort. METHODS: This single-center retrospective cohort study included all consecutive patients treated using ascending aorta wrapping for an acute type A aortic dissection from 2008 to 2019. The primary end points included 30-day mortality, survival during follow-up, and dissection-related mortality. Secondary end points included assessment of aortic remodeling after ascending aorta wrapping. Patients with an aortic anatomy suitable for adjunctive endografting of the ascending aorta were also identified. RESULTS: Thirty-five consecutive patients who underwent ascending aorta wrapping were included. Their median age was 77 years (range, 46-96 years). The 30-day all-cause mortality rate was 9%. Major complications occurred in 7 patients (21%), including early reinterventions in 11 (31%). Median follow-up was 36 months (range, 2.4-106.6; interquartile range, 72). The actuarial survival at 36 months was 82%. The dissection-related mortality was 11.4%. The median aortic growth of the nonwrapped descending thoracic aorta was 3.4 mm. Computed tomography scan analysis depicted that 88% of survivors were theoretical candidates for an additional endovascular procedure to exclude the primary entry tear. CONCLUSIONS: Aortic wrapping is associated with favorable early outcomes and a low rate of aortic events during follow-up. This therapeutic option should be considered for patients considered too fragile for standard surgical repair.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
EJVES Vasc Forum ; 50: 32-36, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33937901

RESUMO

INTRODUCTION: Intravascular lobular capillary haemangioma is a rare benign intravascular tumour, especially in large vessels. This is the report of a case and associated literature review. REPORT AND LITERATURE REVIEW: This is the report of the first case of an intravenous lobular capillary haemangioma (ILCH) of the superior vena cava (SVC). A 30 year old female presented with a collateral thoraco-abdominal venous circulation. Chest computed tomography angiography, thoracic magnetic resonance imaging, and positron emission tomography revealed an intraluminal SVC tumour extending from the left brachiocephalic venous trunk to the distal third of the SVC. No pre-operative biopsy was indicated. An en bloc tumour excision was performed, followed by reconstruction of the SVC with an L shaped, ringed polytetrafluoroethylene (PTFE) prosthesis. Histopathology revealed the presence of an ILCH with free margins. A review of the literature identified 64 cases of ILCH to date, all of which underwent total resection. When reported, no recurrences were found during follow up. DISCUSSION: In this case, the ePTFE reconstruction of the SVC must be checked regularly for any adverse events. Although ILCH is a benign tumour with no risk of recurrence, regular surveillance is advised.

11.
J Cardiovasc Surg (Torino) ; 61(5): 544-554, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32964901

RESUMO

Endovascular treatment has become widespread to treat aneurysmal disease, especially located in the aorta. The modern era of abdominal aortic aneurysm repair started between 1986 and 1991, and in the last 30 years, Endovascular Treatment for abdominal aortic aneurysms evolved both due to the development of new materials and devices and the increasing appeal and effectiveness of the endovascular therapy itself. Vascular surgeons are using nowadays different solutions of Endovascular Treatment to treat all the expressions of aortic pathology (aneurysms, dissections and trauma) both in the acute and elective setting. Despite its use in every location of the aorta (the ascending aorta, the aortic arch, the thoracic aorta, thoraco-abdominal aorta, pararenal, iuxtarenal and infrarenal aortic aneurysms and iliac aneurysms), its safety and efficiency, endovascular treatment for aortic aneurysms presents some drawbacks: despite a lower short-term morbi-mortality, reinterventions and long-term patency are higher compared to open repair. In this review, we detail the most used types of endografts according to location, their performances and durability for each device. We conclude by discussing options to overcome ET limitations. Therefore, an obvious question arises: what we need in the future? What can the technological progress gives to physicians to further improve this new way of treating aorta?


Assuntos
Aorta/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Animais , Aorta/fisiopatologia , Doenças da Aorta/fisiopatologia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Infecções Relacionadas à Prótese/etiologia , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
J Cardiovasc Surg (Torino) ; 61(5): 538-543, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32885928

RESUMO

In the last decades, the main evolution in the field of vascular surgery was correlated to the development and introduction of vascular substitutes. Currently, two types of synthetic vascular substitutes have been widely adopted: polyethylene terephthalate and expanded polytetrafluoroethylene. Ideally, they should demonstrate a behavior as close as possible as that of human arteries in terms of mechanical and biological properties. However, no vascular substitute has been found to compare with the patency rates of gold-standard autologous conduits, and major drawbacks of current vascular substitutes remain both thrombogenicity and infectability.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Politetrafluoretileno/química , Desenho de Prótese , Doenças Vasculares/cirurgia , Animais , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Infecções Relacionadas à Prótese/etiologia , Medição de Risco , Fatores de Risco , Trombose/etiologia , Trombose/fisiopatologia , Resultado do Tratamento , Doenças Vasculares/fisiopatologia , Grau de Desobstrução Vascular
13.
Ann Vasc Surg ; 64: 411.e5-411.e11, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31648036

RESUMO

Adventitial cystic disease is a rare nonatheromatous cause of popliteal artery disease. We report the case of a 49-year-old male patient who presented with left calf claudication caused by adventitial cystic disease. Popliteal artery resection followed by autologous vein graft interposition and Percutaneous Transluminal Angioplasty (PTA) stenting led to recurrence. The patient was finally successfully treated by bypass with autologous vein. No postoperative complications occurred, and patency was preserved at 33-month follow-up. Several different treatment options are possible; however, a primary radical surgical treatment with extra-anatomical medial bypass with autologous vein seems preferable.


Assuntos
Túnica Adventícia/cirurgia , Cistos/cirurgia , Artéria Poplítea/cirurgia , Veia Safena/transplante , Doenças Vasculares/cirurgia , Túnica Adventícia/diagnóstico por imagem , Cistos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Recidiva , Falha de Tratamento , Doenças Vasculares/diagnóstico por imagem
14.
Ann Vasc Surg ; 65: 287.e1-287.e6, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31770572

RESUMO

PURPOSE: The aim of the study was to report the endovascular repair of a ruptured superficial femoral artery (SFA) aneurysm in a young patient with Behcet's disease and review the literature. CASE REPORT: A 43-year-old man with a known history of vasculo-Behcet's disease (v-BD) under daily immunosuppressive therapy presented with a ruptured aneurysm of the left SFA. The patient underwent urgent endovascular exclusion of the aneurysm using a self-expanding covered stent. Surgical cut-down followed by direct puncture of the SFA was preferred to percutaneous approach to reduce the risk of postoperative pseudoaneurysm formation. The procedure and postoperative recovery were successful. Doppler ultrasound performed at 3 months and computed tomography angiography performed at 6 months after the procedure confirmed aneurysm exclusion, the endograft patency, and the absence of aneurysm degeneration both at the level of surgical access and endograft landing zone. CONCLUSIONS: The endovascular treatment of ruptured lower limb aneurysms has been scarcely reported in the literature despite representing the less invasive option. A rare case of ruptured aneurysm SFA in a patient with v-BD was successfully treated with endovascular therapy (ET) and led to satisfactory midterm outcomes. ET offers encouraging results in terms of reduced vessel trauma and reduced postoperative complication rates.


Assuntos
Aneurisma Roto/cirurgia , Síndrome de Behçet/complicações , Implante de Prótese Vascular , Procedimentos Endovasculares , Artéria Femoral/cirurgia , Adulto , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Aneurisma Roto/fisiopatologia , Síndrome de Behçet/diagnóstico , Síndrome de Behçet/tratamento farmacológico , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Imunossupressores/uso terapêutico , Masculino , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
Ann Vasc Surg ; 58: 211-221, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30763709

RESUMO

BACKGROUND: To report perioperative and 1-year results of total endovascular repair of contained ruptured thoracoabdominal aortic aneurysms (TAAAs). METHODS: Between 2015 and 2017, preoperative, procedural, and postoperative data of patients with radiographic evidence of contained ruptured TAAAs treated by endovascular repair were prospectively collected. Only patients with stable hemodynamic parameters were enclosed. Primary endpoints were 30-day/in-hospital mortality, spinal cord ischemia (SCI), postoperative cardiopulmonary complications, and new onset of hemodialysis. Secondary endpoints were endoleaks, reinterventions, and overall follow-up survival. RESULTS: Twelve patients underwent endovascular repair for contained ruptured TAAAs. According with the Crawford/Safi's classification, 6 type II (50%), 3 type III (25%), 1 type IV (8%), and 2 type V (17%) TAAAs were treated. All patients were symptomatic. Overall, 34 target visceral vessels were planned to be revascularized. The mean time from admission to treatment was 48 hours (range 4-96), with 4 patients operated within 24 hours. Five patients (42%) were treated by T-branch, 3 (25%) by custom-made fenestrated/branched endografts, 3 (25%) by parallel graft technique, and 1 (8%) by standard thoracic endovascular aortic repair covering a stenotic celiac trunk. The 30-day and in-hospital mortality was 17% and 25%, respectively. Two patients (17%) developed SCI. Cardiac and pulmonary complications were reported in 1 (8%) and 3 (25%) cases, respectively. One patient (8%) needed permanent hemodialysis. Two endoleaks (17%) were detected at the postoperative computed tomography angiography (1 low-flow gutter endoleak and 1 type III endoleak). Four patients (33%) required re-interventions within 30 postoperative days. The mean follow-up was 12 months (range 1-22). No late target visceral vessels occlusion, endoleak, or reintervention occurred in this series. Overall, 7/12 (59%) patients were alive, and no cases of TAAA-related mortality occurred during follow-up. CONCLUSIONS: According to our results, endovascular repair of contained ruptured TAAAs is feasible by a flexible approach in selected patients with anatomical suitability and stable hemodynamic conditions. Although early mortality and morbidity are significant, with frequent reintervention necessity, subsequent follow-up is free from reinterventions and TAAA-related mortality.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Hemodinâmica , Mortalidade Hospitalar , Humanos , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Surg (Torino) ; 60(1): 41-53, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30160093

RESUMO

Improvements in endovascular technologies and development of custom-made fenestrated and branched endografts currently allow clinicians to treat complex aortic lesions such as thoraco-abdominal and aortic arch aneurysms once treatable with open repair only. These advances are leading to an increase in the complexity of endovascular procedures which can cause long operation times and high levels of radiation exposure. This in turn places pressure on the vascular surgery community to display more superior interventional skills and radiological practices. Advanced imaging technology in this context represents a strong pillar in the treatment toolbox for delivering the best care at the lowest risk level. Delivering the best patient care while managing the radiation and iodine contrast media risks, especially in frail and renal impaired populations, is the challenge aortic surgeons are facing. Modern hybrid rooms are equipped with a wide range of new imaging applications such as fusion imaging and cone-beam computed tomography (CBCT). If these technologies contribute to reducing radiation, they can be complex and intimidating to master. The aim of this review is to discuss the fundamentals of good radiological practices and to describe the various imaging tools available to the aortic surgeon, both those available today and those we anticipate will be available in the near future, from equipment to software, to perform safe and efficient complex endovascular procedures.


Assuntos
Aortografia/métodos , Procedimentos Endovasculares/métodos , Exposição à Radiação/prevenção & controle , Aortografia/efeitos adversos , Aortografia/instrumentação , Humanos
17.
Contrast Media Mol Imaging ; 2018: 7647165, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29780288

RESUMO

Introduction: Iodinated contrast media completion angiography (ICM-A) may underestimate the presence of type II endoleak (ELII) after endovascular aortic repair (EVAR), particularly if they are at low flow. Contrast-enhanced ultrasound (CEUS) has been proposed as the gold standard in ELII detection during EVAR follow-up. Intraprocedural carbon dioxide (CO2) angiography has been shown to be useful in this setting; however no comparative studies including these three techniques are currently available. Our aim was to investigate the accuracy of a new automated CO2 angiographic (CO2-A) system in the detection of ELII, by comparing it with ICM-A and CEUS. Methods: A series of consecutive patients undergoing EVAR for abdominal aortic aneurysm (AAA) were enrolled and submitted to ICM-A and CO2-A during the procedure. The iodinated contrast media were delivered through an automatic injector connected to a pigtail catheter in the suprarenal aorta. CO2 was delivered through a recently available automatic injector connected to a 10 F sheath positioned in the external iliac artery. All patients were blindly evaluated by CEUS within postoperative day 1. The ICM-A and CO2-A ability to detect ELII was compared with that of CEUS through Cohen's concordance Index (K). Results: Twenty-one patients were enrolled in the study. One (5%), seven (33%), and four (19%) ELII were detected by ICM-A, CO2-A, and CEUS, respectively. The only ELII detected by ICM-A was also detected by CO2-A and CEUS. Three cases of ELII detected by CO2-A were not detected by CEUS. All ELII detected by CEUS were visualized by CO2-A. CEUS and ICM-A showed a poor agreement (Cohen's K: 0.35) while CEUS and CO2-A showed a substantial agreement (Cohen's K: 0.65) for ELII detection. Conclusion: CO2-A is safe and effective method for ELII detection in EVAR, with a significantly higher agreement with CEUS if compared with ICM-A. This trial is registered with 155/2015/U/Oss.


Assuntos
Angiografia/métodos , Endoleak/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , Idoso de 80 Anos ou mais , Angiografia/normas , Aneurisma da Aorta Abdominal/complicações , Dióxido de Carbono , Meios de Contraste , Procedimentos Endovasculares , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia/normas
18.
Ann Vasc Surg ; 51: 160-169, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29522871

RESUMO

BACKGROUND: Endovascular aortic repair (EVAR) is presently the preferred treatment for abdominal aortic aneurysm; however, it requires the injection of a contrast medium, which can hamper the renal function. Other nontoxic agents such as carbon dioxide (CO2) have been sporadically tested in this setting with uncertain results. The aim of the study is to investigate the efficacy of a new standardized CO2 injection method in standard EVAR procedures. METHODS: Between August and October 2016, 31 consecutive patients (median age 76.1 [interquartile range {IQR}: 7.4] years) were submitted to standard EVAR. Proximal and distal endograft landing zones were identified by the injection of 100 mL of CO2 at 300 mm Hg, through an 11 cm 10F femoral sheath by a specifically manufactured automated injection device (Angiodroid Srl, San Lazzaro, Bologna, Italy). Before EVAR deployment, a confirmative injection with a conventional contrast medium was accomplished. The possibility of precisely visualizing the proximal and distal landing zones by CO2 digital subtraction angiography (DSA) was evaluated considering the contrast medium injection obtained in the same procedure as a gold standard. Similarly, the possible presence of endoleak was assessed at the end of the procedure by the 2 techniques. RESULTS: CO2 DSA allowed to identify the juxtarenal landing zone of the endograft in 19/31 cases (61%) and the distal one in 31/31 (100%). In 12 (39%) cases, CO2 injection failed to visualize at least the lowest renal artery. This occurred in large aneurysms with scarce thrombotic apposition and a luminal volume greater than 95.9 (IQR: 25.2) mm3. Completion CO2 DSA detected type II endoleaks (ELIIs) in 10 cases compared with 2 of conventional contrast media. CONCLUSIONS: The injection of nontoxic CO2 through an automated device allowed to perform EVAR procedures effectively, in the majority of cases. In some cases, a single injection of a minimum amount of conventional contrast medium can be used to overcome the lack of renal artery visualization by CO2. ELIIs are more frequently visualized with CO2 compared with standard contrast medium. Although the CO2 injection technique needs further amelioration particularly in the renal arteries detection, this technique appears promising and possibly substitutive of the standard contrast medium, with significant benefit for the renal function.


Assuntos
Angiografia Digital/normas , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/normas , Implante de Prótese Vascular , Dióxido de Carbono/administração & dosagem , Cateterismo Periférico/normas , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Automação , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Infusões Intra-Arteriais , Masculino , Valor Preditivo dos Testes , Dados Preliminares , Resultado do Tratamento
19.
J Surg Educ ; 75(2): 534-540, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28870712

RESUMO

OBJECTIVE: Simulation may be a useful tool for training in endovascular procedures. The aim of this study was to evaluate the effect of endovascular repair of abdominal aortic aneurysms (EVAR) simulation in boosting trainees' learning curve. DESIGN: Ten vascular surgery residents were recruited and divided in 2 groups (Trainee Group and Control group). At a first session (t0), each resident performed 2 simulated EVAR procedures using an endovascular simulator. After 2 weeks, each participant simulated other 2 EVAR procedures in a final session (t1). In the period between t0 and t1, each resident in the Trainee Group performed 6 simulated EVAR procedures, whereas the Control Group did not perform any other simulation. Both quantitative and qualitative performance evaluations were performed at t0 and t1. Quantitative evaluation from simulator metrics included total procedural time (TP), total fluoroscopy time (TF), time for contralateral gate cannulation (TG), and contrast medium volume (CM) injected. Qualitative evaluation was based on a Likert scale used to calculate a total performance score referred to skills involving major EVAR procedural steps. RESULTS: All residents in the Trainee Group significantly reduced TP (48 ± 12 vs 32 ± 8 minutes, t0 vs t1, p < 0.05), TF (18 ± 7 vs 11 ± 6 minutes, p < 0.05), and CM used over time (121 ± 37 vs 85 ± 26ml, p < 0.05), but not TG (5 ± 5 vs 3 ± 4 minutes, p = 0.284). In the Control Group metrics did not change significantly in any field (TP = 55 ± 11 vs 46 ± 10 minutes; TF = 25 ± 9 vs 21 ± 4 minutes; CM = 132 ± 51 vs 102 ± 42ml; TG = 6 ± 4 vs 8 ± 5 minutes, all p > 0.05). The average Trainee Group qualitative total performance score improved significantly (p < 0.05) after rehearsal sessions when compared with the Control Group. CONCLUSION: Simulation is an effective method to improve competence of vascular surgery residents with EVAR procedures.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Competência Clínica , Educação de Pós-Graduação em Medicina/métodos , Procedimentos Endovasculares/educação , Imageamento Tridimensional , Treinamento por Simulação/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Hospitais Universitários , Humanos , Internato e Residência/métodos , Itália , Masculino , Melhoria de Qualidade , Valores de Referência , Estatísticas não Paramétricas , Análise e Desempenho de Tarefas , Procedimentos Cirúrgicos Vasculares/educação
20.
Ann Vasc Surg ; 47: 205-211, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28648650

RESUMO

BACKGROUND: The cumulative amount of iodinated contrast medium necessary for endovascular repair (EVAR) planning, operative procedure, and subsequent follow-up is a threat for the onset of end-stage renal disease in patients with preoperative impaired kidney function. The purpose of this study was to describe a mini-invasive approach aimed to minimize the exposure of these patients to iodinated contrast medium and the subsequent risk of renal function worsening. METHODS: From 2012 to 2015, all patients with abdominal aortic aneurysm (AAA) at high surgical risk and fit for standard EVAR (simple aortic-iliac anatomy: proximal and distal neck length ≥15 mm, no severe angulation), underwent EVAR through the following "near-zero contrast" approach, if their glomerular filtration rate (GFR) was <30 mL/min: preoperative planning was performed by noncontrast-enhanced computed tomography and duplex ultrasound (DU); the origin of renal/hypogastric arteries and aortic bifurcation was evaluated and matched with vertebral bone landmarks and the endograft deployed accordingly, using <20 cc of isotonic iodinate contrast medium and contrast-enhancement DU (CEUS). Follow-up was by DU/CEUS at 1, 6, and 12 months. Primary end points were technical success (TS: renal/hypogastric artery patency, absence of type I/III endoleaks, iliac stenosis/kinking, intraoperative mortality, and conversion), 30-day mortality, and new onset of permanent dialysis with renal function evaluation at 1, 6, and 12 months. Secondary end points were type II endoleaks, reinterventions, AAA, and renal-related mortality during the follow-up. RESULTS: Eighteen patients (median age: 74 years, interquartile range [IQR]: 6, male: 78%, American Society of Anaesthesiologists [ASA] IV: 100%) were enrolled. The median AAA diameter and preoperative GFR were 66 mm (IQR: 13) and 22 mL/min (IQR: 4), respectively. Infrarenal (n = 10) and suprarenal fixation (n = 8) endografts were implanted, with a mean dose of iodinate contrast medium injection of 18 mL (IQR) and 100% TS rate. Two type II endoleaks were detected at the completion CEUS. The median postoperative GFR was 22 mL/min (IQR: 5). No patients had GFR worsening ≥30% at 1 day and 30 days. The 30-day mortality was 11% (2 deaths for heart failure). At a median follow-up of 16 months (IQR: 8), no patients needed hemodialytic treatment and no endoleaks were detected. One patient died at 6 months for cancer and one at 13 months for myocardial infarction. No reinterventions or AAA and renal-related mortality occurred during the follow-up. CONCLUSIONS: A "near-zero contrast" approach is feasible in EVAR for patients with simple aorto-iliac anatomy. Patients with very poor renal function may still undergo to successful procedures, avoiding renal function impairment.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Taxa de Filtração Glomerular , Nefropatias/complicações , Falência Renal Crônica/etiologia , Rim/fisiopatologia , Fosfolipídeos/administração & dosagem , Hexafluoreto de Enxofre/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada , Meios de Contraste/efeitos adversos , Progressão da Doença , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Nefropatias/diagnóstico , Nefropatias/mortalidade , Nefropatias/fisiopatologia , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/mortalidade , Falência Renal Crônica/fisiopatologia , Masculino , Seleção de Pacientes , Fosfolipídeos/efeitos adversos , Fatores de Risco , Índice de Gravidade de Doença , Hexafluoreto de Enxofre/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...