Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Chem Neurosci ; 6(3): 374-9, 2015 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-25523270

RESUMO

Large aggregates of misfolded α-synuclein inside neuronal cells are the hallmarks of Parkinson's disease. The protein's natural function and its supposed toxicity, however, are believed to be closely related to its interaction with cell and vesicle membranes. Upon this interaction, the protein folds into an α-helical structure and intercalates into the membrane. In this study, we focus on the changes in the lipid bilayer caused by this intrusion. In situ X-ray reflectivity was applied to determine the vertical density structure of the bilayer before and after exposure to α-synuclein. It was found that the α-synuclein insertion, wild type and E57K variant, caused a reduction in bilayer thickness. This effect may be one factor in the membrane pore formation ability of α-synuclein.


Assuntos
Bicamadas Lipídicas/química , Modelos Moleculares , Raios X , alfa-Sinucleína/química , Animais , Humanos , Mutação/genética , Estrutura Secundária de Proteína , alfa-Sinucleína/genética
2.
ACS Chem Neurosci ; 4(3): 408-17, 2013 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-23509977

RESUMO

The aggregation of α-synuclein (α-Syn) is believed to be one of the key steps driving the pathology of Parkinson's disease and related neurodegenerative disorders. One of the present hypotheses is that the onset of such pathologies is related to the rise of α-Syn levels above a critical concentration at which toxic oligomers or mature fibrils are formed. In the present study, we find that α-Syn aggregation in vitro is a spontaneous process arising at bulk concentrations as low as 1 nM and below in the presence of both hydrophilic glass surfaces and cell membrane mimicking supported lipid bilayers (SLBs). Using three-dimensional supercritical angle fluorescence (3D-SAF) microscopy, we observed the process of α-Syn aggregation in situ. As soon as α-Syn monomers were exposed to the surface, they started to adsorb and aggregate along the surface plane without a prior lag phase. However, at a later stage of the aggregation process, a second type of aggregate was observed. In contrast to the first type, these aggregates showed an extended structure being tethered with one end to the surface and being mobile at the other end, which protruded into the solution. While both types of α-Syn aggregates were found to contain amyloid structures, their growing mechanisms turned out to be significantly different. Given the clear evidence that surface-induced α-Syn aggregation in vitro can be triggered at bulk concentrations far below physiological concentrations, the concept of a critical concentration initiating aggregation in vivo needs to be reconsidered.


Assuntos
Nanotecnologia/métodos , alfa-Sinucleína/metabolismo , Bicamadas Lipídicas/química , Bicamadas Lipídicas/metabolismo , Microscopia de Fluorescência/métodos , Doença de Parkinson/metabolismo , Ligação Proteica/fisiologia , Propriedades de Superfície , alfa-Sinucleína/química
3.
J Am Chem Soc ; 133(48): 19366-75, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-21978222

RESUMO

Parkinson's disease is a common progressive neurodegenerative condition, characterized by the deposition of amyloid fibrils as Lewy bodies in the substantia nigra of affected individuals. These insoluble aggregates predominantly consist of the protein α-synuclein. There is increasing evidence suggesting that the aggregation of α-synuclein is influenced by lipid membranes and, vice versa, the membrane integrity is severely affected by the presence of bound aggregates. Here, using the surface-sensitive imaging technique supercritical angle fluorescence microscopy and Förster resonance energy transfer, we report the direct observation of α-synuclein aggregation on supported lipid bilayers. Both the wild-type and the two mutant forms of α-synuclein studied, namely, the familiar variant A53T and the designed highly toxic variant E57K, were found to follow the same mechanism of polymerization and membrane damage. This mechanism involved the extraction of lipids from the bilayer and their clustering around growing α-synuclein aggregates. Despite all three isoforms following the same pathway, the extent of aggregation and their effect on the bilayers was seen to be variant and concentration dependent. Both A53T and E57K formed cross-ß-sheet aggregates and damaged the membrane at submicromolar concentrations. The wild-type also formed aggregates in this range; however, the extent of membrane disruption was greatly reduced. The process of membrane damage could resemble part of the yet poorly understood cellular toxicity phenomenon in vivo.


Assuntos
Bicamadas Lipídicas/química , alfa-Sinucleína/química , Transferência Ressonante de Energia de Fluorescência , Bicamadas Lipídicas/metabolismo , Microscopia de Fluorescência , Mutagênese Sítio-Dirigida , Mutação , Polimerização , Estrutura Secundária de Proteína , alfa-Sinucleína/genética , alfa-Sinucleína/metabolismo
4.
Opt Express ; 19(7): 6836-44, 2011 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-21451711

RESUMO

A new microscope objective is presented for the parallel fluorescence detection below and above the critical angle of total internal reflection with single molecule sensitivity. The collection of supercritical angle fluorescence (SAF) leads to a strongly surface confined detection volume whereas the collection of undercritical angle fluorescence (UAF) allows for the observation of deeper axial sections of the specimen. By simultaneous detection of the near-field-mediated SAF and the far-field UAF emission modes the z-position of emitters can be obtained on the nanometer scale. We investigate the point spread function of the optics and demonstrate nanoscopic z-localization of single molecules. The oil immersion objective, developed for use on common microscope bodies, opens up new possibilities for the study of topographies and dynamics at surfaces and on membranes.


Assuntos
Aumento da Imagem/instrumentação , Lentes , Microscopia de Fluorescência/instrumentação , Técnicas de Sonda Molecular/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
5.
Adv Colloid Interface Sci ; 162(1-2): 87-106, 2011 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-21295764

RESUMO

Protein adsorption at solid surfaces plays a key role in many natural processes and has therefore promoted a widespread interest in many research areas. Despite considerable progress in this field there are still widely differing and even contradictive opinions on how to explain the frequently observed phenomena such as structural rearrangements, cooperative adsorption, overshooting adsorption kinetics, or protein aggregation. In this review recent achievements and new perspectives on protein adsorption processes are comprehensively discussed. The main focus is put on commonly postulated mechanistic aspects and their translation into mathematical concepts and model descriptions. Relevant experimental and computational strategies to practically approach the field of protein adsorption mechanisms and their impact on current successes are outlined.


Assuntos
Proteínas/química , Adsorção , Animais , Humanos , Cinética , Modelos Moleculares , Conformação Proteica , Propriedades de Superfície
6.
Phys Rev Lett ; 105(10): 108103, 2010 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-20867551

RESUMO

We report a noninvasive fluorescence microscopy method and demonstrate nanometer resolution along the optical axis. The technique is based on the influence of the microscope slide on the angular intensity distribution of fluorescence. Axial positions are determined by measuring the proportion of light emitted below the critical angle of total internal reflection, which behaves in a classical way, and light emitted above the critical angle, which is exponentially dependent on the distance of the fluorophore from the microscope slide.


Assuntos
Microscopia de Fluorescência/métodos , Nanotecnologia/métodos , Animais , Camundongos , Microscopia de Fluorescência/instrumentação , Microesferas , Microtúbulos , Células NIH 3T3 , Nanotecnologia/instrumentação , Tamanho da Partícula
7.
J Phys Chem B ; 114(17): 5862-9, 2010 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-20384354

RESUMO

Cooperative effects play a vital role in protein adsorption events on biological interfaces. Despite a number of studies in this field molecular adsorption mechanisms that include cooperativity are still under debate. In this work we use a Monte Carlo-type simulation to explore the microscopic details behind cooperative protein adsorption. The simulation was designed to implement our previously proposed mechanism through which proteins are not necessarily rejected if they approach the surface to an occupied region. Instead, we suggest that proteins can be tracked laterally for a certain distance due to the influence of preadsorbed proteins in order to reach the nearest available binding site. The simulation results were compared with experimental data obtained by using the supercritical angle fluorescence (SAF) microscopy technique. It was found that the tracking distance may be up to 2.5 times the protein's diameter depending on the investigated system. The general validity of this tracking mechanism is supported by a number of linear or upward concave adsorption kinetics reported in the literature which are consistent with our simulation results. Furthermore, the self-organization of proteins adsorbing under cooperative conditions on the surface is shown to necessarily cause density inhomogeneities in the surface distribution of proteins which is also in agreement with experimental observations.


Assuntos
Método de Monte Carlo , Proteínas/química , Adsorção , Cinética , Microscopia de Fluorescência , Propriedades de Superfície
8.
J Phys Chem B ; 112(44): 13971-80, 2008 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-18842014

RESUMO

Despite many experimental studies on cooperative effects during protein adsorption events, this phenomenon is still poorly characterized and subject of much controversy. In this study, we address the topic of cooperativity using two distinct experimental approaches, namely, kinetic analysis and surface imaging, both based on supercritical angle fluorescence (SAF) microscopy. Several model systems comprising the two proteins BSA and fibrinogen, two different ionic strength conditions and varying pH environments were investigated. The combination of the experimental information obtained from kinetic analysis and from real-time in situ scan images unravel a clear correlation between cooperative adsorption and a heterogeneous protein layer build-up. We propose a mechanistic model of protein adsorption based on an overlap of classical Langmuir-type adsorption on unoccupied surface areas and an additional cooperative adsorption pathway near preadsorbed proteins which is consistent with the experimental observations. Moreover, the growth of two-dimensional surface clusters as an often assumed element of cooperativity could be excluded for the studied systems. The model includes the often observed phenomenon that the adsorption rate decelerates abruptly above a certain coverage limit. Furthermore, the observed evolution of the heterogeneous protein distribution on the surface is in good agreement with the proposed model.


Assuntos
Fibrinogênio/química , Soroalbumina Bovina/química , Adsorção , Animais , Bovinos , Concentração de Íons de Hidrogênio , Modelos Biológicos , Propriedades de Superfície
9.
Langmuir ; 24(3): 1053-7, 2008 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-18154313

RESUMO

We present a simple and versatile technique of tailoring functionalized surface structures for protein enrichment and purification applications based on a superhydrophobic silicone nanofilament coating. Using amino and carboxyl group containing silanes, silicone nanofilament templates were chemically modified to mimic anionic and cationic exchange resins. Investigations on the selectivity of the functionalized surfaces toward adsorption of charged model proteins were carried out by means of fluorescence techniques. Due to a high contact area resulting from the nanoroughness of the coating, excellent protein retention characteristics under various conditions were found. The surfaces were shown to be highly stable and reusable over several retention-elution cycles. Especially the full optical transparency and the possibility to use glass substrates as support material open new opportunities for the development of optical biosensors, open geometry microfluidics, or lab-on-a-chip devices.


Assuntos
Nanoestruturas/química , Nanoestruturas/ultraestrutura , Proteínas/isolamento & purificação , Silicones/química , Técnicas Biossensoriais , Materiais Revestidos Biocompatíveis/química , Microscopia Eletrônica de Varredura , Nanotecnologia , Propilaminas , Silanos
10.
Biophys J ; 94(1): 221-9, 2008 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17827221

RESUMO

We explore the potential of a supercritical angle (SA) objective for fluorescence correlation spectroscopy (FCS). This novel microscope objective combines tight focusing by an aspheric lens with strong axial confinement of supercritical angle fluorescence collection by a parabolic mirror lens, resulting in a small detection volume. The tiny axial extent of the detection volume features an excellent surface sensitivity, as is demonstrated by diffusion measurements in model membranes with an excess of free dye in solution. All SA-FCS measurements are directly compared to standard confocal FCS, demonstrating a clear advantage of SA-FCS, especially for diffusion measurements in membranes. We present an extensive theoretical framework that allows for accurate and quantitative evaluation of the SA-FCS correlation curves.


Assuntos
Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Refratometria/instrumentação , Refratometria/métodos , Espectrometria de Fluorescência/instrumentação , Espectrometria de Fluorescência/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Biomed Opt ; 12(3): 034012, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17614720

RESUMO

We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles above the critical angle of the waterglass interface. An aspheric lens, incorporated into the solid parabolic element, is used for diffraction-limited laser focusing and for collecting fluorescence at low angles with respect to the optical axis. By separated collection of the fluorescence emitted into supercritical and subcritical angles, two detection volumes strongly differing in their axial resolution are generated at the surface of a glass cover slip. The collection of supercritical angle fluorescence (SAF) results in a strict surface confinement of the detection volume, whereas collecting below the critical angle allows gathering the fluorescence emitted several microns deep inside the sample. Consequently, the signals from surface-bound and unbound diffusing fluorescent molecules can be obtained simultaneously.


Assuntos
Aumento da Imagem/instrumentação , Microscopia de Fluorescência por Excitação Multifotônica/instrumentação , Óptica e Fotônica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Chemphyschem ; 8(6): 862-72, 2007 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-17387668

RESUMO

We investigate nonspecific protein adsorption processes by comparing experimentally measured adsorption kinetics of beta-lactoglobulin with mathematical models. The adsorption and desorption behavior of this protein on a hydrophilic glass surface in citrate buffer (pH 3.0), monitored for a large set of different bulk concentrations (0.5x10(-8) M-1.5x10(-6) M) using a supercritical angle fluorescence (SAF) biosensor, is reported. Increasing adsorption rates and overshootings in the beginning of the adsorption are observed as well as a transition to an almost irreversibly bound state of the protein in the long term. Furthermore, rinsing experiments prove that adsorbed proteins abruptly change their desorption behavior from irreversible to reversible when a critical surface coverage theta(crit) is reached. Based on all experimental observations, a mathematical model composed of three adsorbed states differing in their surface affinity is proposed. Terms to account for lateral interactions between surface-bound proteins are included, which yield an excellent fit of the measured kinetics. For the first time, several phenomena that have been discussed in theoretical studies are confirmed by comparing experimental data with a single model.


Assuntos
Técnicas Biossensoriais/métodos , Lactoglobulinas/química , Adsorção , Soluções Tampão , Corantes Fluorescentes/química , Vidro/química , Concentração de Íons de Hidrogênio , Cinética , Modelos Químicos , Propriedades de Superfície
13.
Biosens Bioelectron ; 20(9): 1872-7, 2005 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15681208

RESUMO

We developed a fluorescence reader for the sensitive detection of surface-generated fluorescence. The system is applicable for high resolution imaging as well as for the readout of large biochips. The surface of a microscope coverslip is scanned with a laser beam focused to a waist diameter of 500 nm (FWHM) by means of a single aspheric lens. Scanning large areas with a focused beam usually evokes the need of automatic control elements to adjust the laser spot to the designated position at the surface. Due to the special design of the reader, the focus keeps at the plane of the surface even when scanning large areas, obviating the requirement of any real time control. Thus the instrument is straightforward and inexpensive. Nevertheless it features a high sensitivity and high optical resolution. The versatility of the instrument is demonstrated by imaging cells and reading out a DNA-chip. The excellent sensitivity is shown by detecting single fluorescently labeled antibodies.


Assuntos
Técnicas Biossensoriais/instrumentação , Análise em Microsséries/instrumentação , Microscopia Confocal/instrumentação , Microscopia de Fluorescência/instrumentação , Técnicas Biossensoriais/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise em Microsséries/métodos , Microscopia Confocal/métodos , Microscopia de Fluorescência/métodos
14.
Opt Express ; 12(18): 4246-54, 2004 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-19483970

RESUMO

We explore a new confocal microscope for the detection of surface-generated fluorescence. The instrument is designed for high resolution imaging as well as for the readout of large biochips. Special feature is the separated collection of two different fluorescence emission modes. One optical path covers the emission into the glass at low surface angles, the other captures high angles, exceeding the critical angle of the water/glass interface. Due to the collection of the supercritical angle fluorescence (SAF) the confocal detection volume is strictly confined to the interface, whereas the low angles collect much deeper from the aqueous analyte solution. Hence the system can deliver information about surfacebound and unbound fraction of fluorescent analyte simultaneously.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...