J Anal Toxicol ; 6(6): 294-6, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-7162139

RESUMO

Published gas-liquid chromatographic (GLC) methods for the determination of nicotine and cotinine have proved impractical for the analysis of a large number of clinical samples. Significant improvements over other methods have been achieved, being low sample volume (0.5 mL plasma), rapid two-step extraction from plasma, no evaporation step, and good separation. The lower limits of sensitivity for nicotine and cotinine were 1 and 5 ng/mL, respectively. The method was validated by the analysis of plasma samples from cigarette-smoking volunteers. The method described permits the quick, routine determination of nicotine and cotinine in a large number of samples.


Assuntos
Cotinina/sangue , Nicotina/sangue , Pirrolidinonas/sangue , Cromatografia Gasosa , Humanos , Fumar
SELEÇÃO DE REFERÊNCIAS