Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Mal Respir ; 34(3): 253-256, 2017 Mar.
Artigo em Francês | MEDLINE | ID: mdl-28341128

RESUMO

INTRODUCTION: Surgical resection is usually performed for the treatment of endobronchial tumors. This case describes the use of endoscopic resection as an initial treatment, allowing to spare lung parenchyma. CASE REPORT: A patient was admitted to the emergency unit with right lower lobe pneumonia. A thoracic CT-scan and subsequent bronchoscopy revealed an intrabronchial tumor between the right main and intermediate bronchus. Biopsies were non-diagnostic and a PET-scanner did not find any abnormalities. Surgical resection was initially proposed but would have required a right upper lobectomy. The patient had stage 2 (moderate) chronic obstructive pulmonary disease (GOLD classification). Because of this, we decided to perform an endoscopic resection to obtain further histology and hopefully achieve total removal. Under conscious sedation, the resection by argon plasma coagulation with a flexible bronchoscope was realized without any complication. The histological diagnosis was a bronchial mucous gland adenoma. CONCLUSION: This case emphasizes the role of multidisciplinary discussion when considering suitability of local resection of tumors by an endobronchial procedure rather than a surgical resection.


Assuntos
Adenoma/diagnóstico , Brônquios/diagnóstico por imagem , Neoplasias Brônquicas/diagnóstico , Broncoscopia , Brônquios/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa/diagnóstico por imagem , Mucosa/patologia
2.
Opt Express ; 15(11): 6900-7, 2007 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-19547004

RESUMO

We present a quantitative study on the fabrication of microlenses using a low-cost polymer dispending technique. Our method is based on the use of a silicon micro-cantilever robotized spotter system. We first give a detailed description of the technique. In a second part, the fabricated microlenses are fully characterized by means of SEM (Scanning Electron Microscope), AFM (Atomic Force Microscopy) non contact optical profilometry and Mach-Zehnder interferometry. Diameters in the range [25-130mum] are obtained with an average surface roughness of 2.02nm. Curvature radii, focal lengths as well as aberrations are also measured for the first time: the fabricated microlenses present focal lengths in the range [55-181mum] and exhibit high optical quality only limited by diffraction behaviour with RMS aberration lower than lambda/14.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...