Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 16(23): 2854-2865, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37999708

RESUMO

BACKGROUND: A significant number of patients with severe mitral regurgitation (MR) are not suitable for either surgical or transcatheter edge-to-edge repair because of high surgical risk or inappropriate mitral valve anatomy. OBJECTIVES: The aim of this study was to evaluate the HighLife Trans-Septal Mitral Valve Replacement (TSMVR) system in patients with symptomatic MR and high surgical risk. METHODS: This prospective, multicenter, nonrandomized feasibility study evaluated the safety and performance of the HighLife TSMVR system in patients with moderate to severe or severe symptomatic MR during 1-year follow-up. Echocardiographic data were assessed at an independent core laboratory. RESULTS: A total of 30 patients (mean age 75.6 years, 27% women, median Society of Thoracic Surgeons score 5.5%) with severe MR (90% with secondary MR, median left ventricular ejection fraction 43%) were treated at 13 sites. In 27 of the 30 patients, the HighLife TSMVR system was implanted successfully (technical success rate 90%). Device success at 30 days was 83%. After 1 year, 5 patients (17%) had died. None of the patients who underwent implantation required mitral valve reintervention. All patients who underwent implantation had no or trace (78%) or mild (22%) MR, the mean gradient of the HighLife valve was 5.1 mm Hg, and there were no signs of left ventricular outflow tract obstruction (mean gradient 2.0 mm Hg). CONCLUSIONS: The 1-year results from the HighLife TSMVR feasibility study demonstrate a high technical success rate, excellent valve function, no left ventricular outflow tract obstruction, and no need for mitral valve reintervention. Additional patient outcomes and longer follow-up are needed to confirm these findings. (Expanded Study of the HighLife 28mm Trans-Septal Trans-Catheter Mitral Valve in Patients With Moderate-Severe or Severe Mitral Regurgitation and at High Surgical Risk; NCT04029363).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Estudos de Viabilidade , Estudos Prospectivos , Função Ventricular Esquerda , Resultado do Tratamento , Cateterismo Cardíaco
2.
Semin Thorac Cardiovasc Surg ; 34(3): 985-991, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33984478

RESUMO

Valved allografts and xenografts for reconstruction of the right ventricular outflow tract (RVOT) lack durability and do not grow. We report the first clinical use of a completely bioabsorbable valved conduit (Xeltis pulmonary valve - XPV) in children. Twelve children (six male), median age five (two to twelve) years and median weight 17 (10 to 43) kg, underwent RVOT reconstruction with the XPV. Diagnoses were: pulmonary atresia with ventricular septal defect (VSD) (n = 4), tetralogy of Fallot (n = 4), common arterial trunk (n = 3), and transposition of the great arteries with VSD and pulmonary stenosis (n = 1). All had had previous surgery, including prior RVOT conduit implantation in six. Two diameters of conduit 16mm (n = 5) and 18mm (n = 7) were used. At 24 months none of the patients has required surgical re-intervention, 9 of the 12 are in NYHA functional class I and three patients in NYHA class II. None of the conduits has shown evidence of progressive stenosis, dilation or aneurysm formation. Residual peak gradient of >40 mm Hg was observed in three patients, caused by kinking of the conduit at implantation in 1 and distal stenosis in the peripheral pulmonary arteries in 2 patients. Five patients developed severe pulmonary valve insufficiency (PI); the most common mechanism was prolapse of at least one of the valve leaflets. The XPV conduit is a promising innovation for RVOT reconstruction. Progressive PI requires however an improved design (geometry, thickness) of the valve leaflets.


Assuntos
Bioprótese , Comunicação Interventricular , Próteses Valvulares Cardíacas , Valva Pulmonar , Transposição dos Grandes Vasos , Obstrução do Fluxo Ventricular Externo , Criança , Pré-Escolar , Constrição Patológica , Feminino , Comunicação Interventricular/cirurgia , Humanos , Masculino , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/cirurgia
3.
Thorac Cardiovasc Surg ; 68(2): 114-123, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-30497085

RESUMO

INTRODUCTION: Sutureless biological valves for surgical aortic valve replacement (SAVR), characterized by the absence of anchoring sutures at the aortic annulus, are gaining popularity because of ease and reproducibility of implant, shorter operating times, and enhancement of minimally invasive approaches. The stentless configuration of the sutureless valve was designed to achieve optimal hemodynamic performance. MATERIALS AND METHODS: PERSIST-AVR (PERceval Sutureless Implant versus STandard Aortic Valve Replacement) is a prospective, randomized, adaptive, open-label, international, postmarket trial (NCT02673697). The primary objective of the trial is to assess the safety and efficacy of the Perceval (LivaNova, London, UK) sutureless bioprosthesis among patients undergoing SAVR in the presence of severe aortic stenosis to demonstrate the noninferiority of Perceval as compared with standard sutured stented bioprosthetic aortic valve as an isolated procedure or combined with coronary artery bypass grafting. Sample size will be determined adaptively through interim analyses performed by an Independent Statistical Unit till a maximum of 1,234 patients, enrolled at ∼60 sites in countries where the device is commercially available. Patients will be followed up for 5 years after implant. The primary end point is the number of patients free from major adverse cardiac and cerebrovascular-related events at 1 year. Additional secondary outcomes will be assessed up to 5 years. DISCUSSION: PERSIST-AVR is the first prospective, randomized study comparing in-hospital and postdischarge outcomes in a robust population of patients undergoing SAVR with either the Perceval sutureless bioprosthesis or a conventional sutured stented bioprosthesis up to 5 years.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Stents , Procedimentos Cirúrgicos sem Sutura/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Procedimentos Cirúrgicos sem Sutura/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
4.
Eur Heart J ; 38(10): 730-738, 2017 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-27941020

RESUMO

AIMS: Although cardiac resynchronization therapy (CRT) is effective in patients with systolic heart failure (HF) and a wide QRS interval, a substantial proportion of patients remain non-responsive. The SonR contractility sensor embedded in the right atrial lead enables individualized automatic optimization of the atrioventricular (AV) and interventricular (VV) timings. The RESPOND-CRT study investigated the safety and efficacy of the contractility sensor system in HF patients undergoing CRT. METHODS AND RESULTS: RESPOND-CRT was a prospective, randomized, double-blinded, multicentre, non-inferiority trial. Patients were randomized (2:1, respectively) to receive weekly, automatic CRT optimization with SonR vs. an Echo-guided optimization of AV and VV timings. The primary efficacy endpoint was the rate of clinical responders (patients alive, without adjudicated HF-related events, with improvement in New York Heart Association class or quality of life), at 12 months. The study randomized 998 patients. Responder rates were 75.0% in the SonR arm and 70.4% in the Echo arm (mean difference, 4.6%; 95% CI, -1.4% to 10.6%; P < 0.001 for non-inferiority margin -10.0%) (Table 2). At an overall mean follow-up of 548 ± 190 days SonR was associated with a 35% risk reduction in HF hospitalization (hazard ratio, 0.65; 95% CI, 0.46-0.92; log-rank P = 0.01). CONCLUSION: Automatic AV and VV optimization using the contractility sensor was safe and as effective as Echo-guided AV and VV optimization in increasing response to CRT. CLINICALTRIALS.GOV NUMBER: NCT01534234.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica/terapia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Método Duplo-Cego , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca Sistólica/fisiopatologia , Humanos , Masculino , Contração Miocárdica/fisiologia , Estudos Prospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...