Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Clin Microbiol Infect ; 29(2): 225-232, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36028089

RESUMO

OBJECTIVES: Antigen rapid diagnostic tests (RDTs) for SARS coronavirus 2 (SARS-CoV-2) are quick, widely available, and inexpensive. Consequently, RDTs have been established as an alternative and additional diagnostic strategy to quantitative reverse transcription polymerase chain reaction (RT-qPCR). However, reliable clinical and large-scale performance data specific to a SARS-CoV-2 virus variant of concern (VOC) are limited, especially for the Omicron VOC. The aim of this study was to compare RDT performance among different VOCs. METHODS: This single-centre prospective performance assessment compared RDTs from three manufacturers (NADAL, Panbio, MEDsan) with RT-qPCR including deduced standardized viral load from oropharyngeal swabs for detection of SARS-CoV-2 in a clinical point-of-care setting from November 2020 to January 2022. RESULTS: Among 35 479 RDT/RT-qPCR tandems taken from 26 940 individuals, 164 of the 426 SARS-CoV-2 positive samples tested true positive with an RDT corresponding to an RDT sensitivity of 38.50% (95% CI, 34.00-43.20%), with an overall specificity of 99.67% (95% CI, 99.60-99.72%). RDT sensitivity depended on viral load, with decreasing sensitivity accompanied by descending viral load. VOC-dependent sensitivity assessment showed a sensitivity of 42.86% (95% CI, 32.82-53.52%) for the wild-type SARS-CoV-2, 43.42% (95% CI, 32.86-54.61%) for the Alpha VOC, 37.67% (95% CI, 30.22-45.75%) for the Delta VOC, and 33.67% (95% CI, 25.09-43.49%) for the Omicron VOC. Sensitivity in samples with high viral loads of ≥106 SARS-CoV-2 RNA copies per mL was significantly lower in the Omicron VOC (50.00%; 95% CI, 36.12-63.88%) than in the wild-type SARS-CoV-2 (79.31%; 95% CI, 61.61-90.15%; p 0.015). DISCUSSION: RDT sensitivity for detection of the Omicron VOC is reduced in individuals infected with a high viral load, which curtails the effectiveness of RDTs. This aspect furthert: limits the use of RDTs, although RDTs are still an irreplaceable diagnostic tool for rapid, economic point-of-care and extensive SARS-CoV-2 screening.


Assuntos
COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Estudos Prospectivos , RNA Viral , COVID-19/diagnóstico , SARS-CoV-2/genética , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...