Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dentomaxillofac Radiol ; 46(2): 20160253, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27996305

RESUMO

OBJECTIVES: (1) To compare the efficacy of a commercially available hygienic sheath and an alternative plastic bag in preventing contamination of the imaging plate during intraoral radiography and (2) to compare patient discomfort when using the hygienic sheath and the plastic bag. METHODS: 60 sterilized Size 2 imaging plates covered with either the hygienic sheath (n = 30) or the plastic bag (n = 30) were used to simulate digital periapical radiographic examination in 30 volunteer patients. After disinfection, each plate was swabbed. The swabbed medium was then plated on trypticase soy agar and incubated. Bacterial colonies were counted. Patient discomfort was assessed using a visual analogue scale (VAS) score. The comparison of the number of bacterial colonies and VAS scores between the two groups was tested by paired t-test at p < 0.05. RESULTS: There was no significant difference in the number of bacterial colonies between the two groups (p = 0.745). Of all the plates, 10% plates yielded bacterial colonies. The mean count of bacterial colonies for both groups was 10-20 CFU ml-1. However, there was a significant difference between VAS scores for the two systems (p = 0.000). The mean VAS scores (range 0-10) for patient discomfort for the hygienic sheath group and the plastic bag group were 3.03 and 5.33, respectively. CONCLUSIONS: Based on the design of this study, the alternative barrier provided similar results to those commercially available. Regarding the type of barrier envelope, the hygienic sheath induced less discomfort than the plastic bag.


Assuntos
Controle de Infecções , Contaminação de Equipamentos , Humanos , Viabilidade Microbiana , Plásticos , Radiografia Dentária Digital
2.
Imaging Sci Dent ; 46(1): 1-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27051633

RESUMO

PURPOSE: This study assessed the accuracy of age estimates produced by a regression equation derived from lower third molar development in a Thai population. MATERIALS AND METHODS: The first part of this study relied on measurements taken from panoramic radiographs of 614 Thai patients aged from 9 to 20. The stage of lower left and right third molar development was observed in each radiograph and a modified Gat score was assigned. Linear regression on this data produced the following equation: Y=9.309+1.673 mG+0.303S (Y=age; mG=modified Gat score; S=sex). In the second part of this study, the predictive accuracy of this equation was evaluated using data from a second set of panoramic radiographs (539 Thai subjects, 9 to 24 years old). Each subject's age was estimated using the above equation and compared against age calculated from a provided date of birth. Estimated and known age data were analyzed using the Pearson correlation coefficient and descriptive statistics. RESULTS: Ages estimated from lower left and lower right third molar development stage were significantly correlated with the known ages (r=0.818, 0.808, respectively, P≤0.01). 50% of age estimates in the second part of the study fell within a range of error of ±1 year, while 75% fell within a range of error of ±2 years. The study found that the equation tends to estimate age accurately when individuals are 9 to 20 years of age. CONCLUSION: The equation can be used for age estimation for Thai populations when the individuals are 9 to 20 years of age.

3.
Imaging Sci Dent ; 41(4): 143-50, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22232722

RESUMO

PURPOSE: The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. MATERIALS AND METHODS: One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve (A(z)) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). RESULTS: The mean A(z) values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest A(z) value. CONCLUSION: Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...