Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Dent Educ ; 82(9): 916-920, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30173186

RESUMO

To date, there has been a lack of published studies examining the validity of the Health Sciences Reasoning Test (HSRT) to assess critical thinking among dental students. The aim of this study was to examine the construct validity of the HSRT using a novice-expert model consisting of first-year dental students as novices and experienced general dentists as experts. Novice cohort subjects were recruited from all 105 students in the first-year dental school class at the University of Texas Health Science Center at San Antonio during a regularly scheduled course in August 2015. A total of 83 students participated, for a 79% response rate. Thirty individuals personally recruited from the same school's faculty and from private practitioners made up the expert cohort. The results showed that the adjusted mean overall score for the expert cohort (25.31) was significantly higher than that of the novice cohort (22.64) (p=0.04). The expert cohort achieved higher adjusted mean scores in all scales (Induction, Deduction, Analysis, Inference, and Evaluation), with the difference in the Analysis scale being significant (p=0.02). In this study, experienced general dentists achieved significantly better overall scores on the HSRT as compared to first-year dental students, suggesting the instrument was able to measure differences between novice and expert. Further efforts to validate the instrument in a dental education setting and to understand its correlation with strategies and practices aimed at developing critical thinking in dental students are warranted.


Assuntos
Odontólogos/psicologia , Resolução de Problemas , Testes Psicológicos , Estudantes de Odontologia/psicologia , Pensamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
2.
J Prosthodont ; 23(1): 31-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23889695

RESUMO

PURPOSE: The purpose of this study was to evaluate a novel intraoral monitor for measuring patient compliance of oral appliances for the treatment of obstructive sleep apnea. MATERIALS AND METHODS: A clinical trial was conducted to compare objective recording by an intraoral compliance monitor and self-reporting by participants using a mandibular repositioning device (MRD). Ten participants were fitted with a Thornton Adjustable Positioner (TAP III) with an embedded compliance monitor. The participants were asked to wear the test appliance for seven nights and to record their usage of the appliance and any adverse effects in a treatment journal. The data were downloaded to a dedicated computer using radio-frequency identification (RFID) technology, and the information was compared to the data in the participant's journal. RESULTS: The mean objective wearing time, as detected by the compliance monitor, was found to be 6.6 ± 1.6 hours/night. The mean subjective wearing time, as recorded by the participants, was 6.5 ± 1.5 hours/night. The correlation between subjective and objective times was 0.9985. The use of the test appliance by this sample population was 68.7% with a range of 24% to 100%. Participants reported a range of adverse outcomes related to the MRD consistent with those reported in the literature and were found to be transient in nature. CONCLUSIONS: This study supports previously reported usage times and adverse outcomes. The compliance monitor showed a very high linear correlation between subjective and objective data, validating its use in future compliance studies.


Assuntos
Monitorização Ambulatorial/instrumentação , Aparelhos Ortodônticos , Cooperação do Paciente , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Má Oclusão/etiologia , Avanço Mandibular/efeitos adversos , Avanço Mandibular/instrumentação , Prontuários Médicos , Microcomputadores , Pessoa de Meia-Idade , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos/efeitos adversos , Dispositivo de Identificação por Radiofrequência/métodos , Autorrelato , Transtornos da Articulação Temporomandibular/etiologia , Termômetros , Fatores de Tempo , Xerostomia/etiologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-21837300

RESUMO

The primary aim of this study was to evaluate the differences in labial plate thickness in patients identified as having thin versus thick/average periodontal biotypes. The association between biotype and labial plate thickness was evaluated by correlating information obtained from cone beam computed tomographs, diagnostic impressions, and clinical examinations of the maxillary anterior teeth (canine to canine) in 60 patients. Compared to a thick/average biotype, a thin biotype was associated with thinner labial plate thickness (P < .001), narrower keratinized tissue width (P < .001), greater distance from the cementoenamel junction to the initial alveolar crest (P = .02), and probe visibility through the sulcus. There was no relationship between biotype and tooth height-to-width ratio or facial recession. Periodontal biotype is significantly related to labial plate thickness, alveolar crest position, keratinized tissue width, gingival architecture, and probe visibility but unrelated to facial recession.


Assuntos
Processo Alveolar/anatomia & histologia , Periodonto/anatomia & histologia , Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Dente Canino/anatomia & histologia , Dente Canino/diagnóstico por imagem , Arco Dental/anatomia & histologia , Gengiva/anatomia & histologia , Hemorragia Gengival/patologia , Retração Gengival/patologia , Humanos , Incisivo/anatomia & histologia , Incisivo/diagnóstico por imagem , Queratinas , Maxila/anatomia & histologia , Maxila/diagnóstico por imagem , Modelos Dentários , Odontometria , Perda da Inserção Periodontal/patologia , Bolsa Periodontal/patologia , Periodontia/instrumentação , Colo do Dente/anatomia & histologia , Colo do Dente/diagnóstico por imagem , Coroa do Dente/anatomia & histologia , Raiz Dentária/diagnóstico por imagem
4.
J Prosthet Dent ; 100(2): 147-52, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18672130

RESUMO

Nasal continuous positive airway pressure (CPAP) is an effective treatment for obstructive sleep apnea (OSA). Airway obstruction is prevented by delivering air at a constant pressure via a nasal mask worn during sleep. Small nares may cause difficulty in wearing even the smallest standard nasal mask, with wear resulting in discomfort and air leaks. This article describes a method for fabricating a custom nasal CPAP mask using maxillofacial prosthodontic laboratory techniques.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Máscaras , Apneia Obstrutiva do Sono/terapia , Resinas Acrílicas , Desenho de Equipamento , Humanos , Elastômeros de Silicone
6.
J Prosthodont ; 16(2): 136-40, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17362424

RESUMO

Plastic test patterns were milled to simulate casting margins and were cast in a variety of dental alloys. The cast specimens were exposed to horizontal and vertical streams of low-pressure microabrasion with 50 microm aluminum oxide particles. Post-exposure measurements show all specimens were affected by microabrasion. Dentists and laboratory technicians who use microabrasion must be aware of the potential damage to casting margins.


Assuntos
Abrasão Dental por Ar/efeitos adversos , Ligas Dentárias/química , Adaptação Marginal Dentária , Teste de Materiais/métodos
7.
J Prosthet Dent ; 94(4): 394-7, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16198179

RESUMO

When a patient with a nonrestorable dentition desires an immediate restoration, fabrication and use of a stable surgical template can be challenging. Conventionally made surgical templates may lack stability and may, therefore, be less predictable. This article describes the fabrication of a surgical template that permitted the use of staged tooth extraction to facilitate predictable immediate implant placement in a patient with a nonrestorable dentition.


Assuntos
Implantação Dentária Endóssea/instrumentação , Implantes Dentários , Extração Dentária/métodos , Dente Suporte , Implantação Dentária Endóssea/métodos , Técnica de Moldagem Odontológica/instrumentação , Desenho de Equipamento , Humanos , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Modelos Dentários , Planejamento de Assistência ao Paciente , Tomografia Computadorizada por Raios X
8.
J Prosthet Dent ; 93(1): 21-3, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15623993

RESUMO

Commonly observed complications associated with a conventional fixed partial denture (FPD) include loss of retention and tooth fracture. This report describes the occurrence of an unusual FPD abutment fracture and subsequent treatment. The distal abutment of an FPD developed severe periodontal disease with mobility. The anterior abutment fractured in the middle of the clinical crown and experienced cement failure.


Assuntos
Dente Suporte , Falha de Restauração Dentária , Prótese Parcial Fixa , Idoso , Feminino , Humanos , Tratamento do Canal Radicular/métodos , Fraturas dos Dentes/etiologia , Fraturas dos Dentes/terapia , Mobilidade Dentária/etiologia
10.
J Prosthodont ; 12(1): 13-6, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12677606

RESUMO

In clinical practice, it is necessary to remove a ceramic-veneered fixed partial denture when an abutment becomes loose. When possible, the fixed partial denture is removed in a single piece, allowing recementation when appropriate. A 1-piece removal is challenging, often putting the veneer and abutment teeth at risk for damage. This article describes a technique for fabricating and using a 2-piece matrix that both protects the prosthesis and better directs removal forces along the long axis of the abutments.


Assuntos
Descolagem Dentária/métodos , Falha de Restauração Dentária , Retenção de Dentadura , Prótese Parcial Fixa , Ligas Metalo-Cerâmicas , Resinas Acrílicas , Cimentação , Cerâmica , Dente Suporte , Descolagem Dentária/instrumentação , Facetas Dentárias , Reparação em Dentadura/métodos , Humanos , Torque
11.
Tex Dent J ; 120(12): 1128-35, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14740392

RESUMO

Application of the crown preparation guidelines obtained through theoretical models, laboratory testing and clinical studies provide an evidence-based rationale for clinical practice procedures. The evidence-based rationale has been presented to support basic day-to-day techniques in clinical practice. As new techniques and materials are developed, each should be evaluated carefully prior to clinical use and acceptance.


Assuntos
Coroas , Coroas/efeitos adversos , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Retenção em Prótese Dentária , Gengivite/etiologia , Humanos , Preparo Prostodôntico do Dente , Dimensão Vertical
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...