Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 48(9): 2856-2870, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33517517

RESUMO

PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based "digital" systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL-1 [18F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm3) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOIcold) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed. RESULTS: Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSFON and PSFOFF, respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSFON, RCGMe = [0.97-1.01] and GMWMre = [3.51-3.91] for eroded VOI and RCGM = [0.78-0.83] and GMWMr = [1.77-2.06] for non-eroded VOI, and for PSFOFF, RCGMe = [0.92-0.99] and GMWMre = [3.14-3.68] for eroded VOI and RCGM = [0.75-0.81] and GMWMr = [1.72-1.95] for non-eroded VOI. CONCLUSIONS: To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RCGMe and GMWMre as specified in "Results". These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Encéfalo/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
3.
EJNMMI Phys ; 3(1): 30, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27957730

RESUMO

BACKGROUND: [18F]HX4 is a promising new PET tracer developed to identify hypoxic areas in tumor tissue. This study analyzes [18F]HX4 kinetics and assesses the performance of simplified methods for quantification of [18F]HX4 uptake. To this end, eight patients with non-small cell lung cancer received dynamic PET scans at three different time points (0, 120, and 240 min) after injection of 426 ± 72 MBq [18F]HX4, each lasting 30 min. Several compartment models were fitted to time activity curves (TAC) derived from various areas within tumor tissue using image-derived input functions. RESULTS: Best fits were obtained using the reversible two-tissue compartment model with blood volume parameter (2T4k+VB). Simplified measures correlated well with VT estimates (tumor-to-blood ratio (TBr) R 2 = 0.96, tumor-to-muscle ratio R 2 = 0.94, standardized uptake value R 2 = 0.89). CONCLUSIONS: [18F]HX4 shows reversible kinetics in tumor tissue: 2T4k+VB. TBr based on static imaging at 2 or 4 h can be used for quantification of [18F]HX4 uptake.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...