Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
Materials (Basel) ; 17(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38541534

RESUMO

The objective of this study was to review the scientific evidence currently available on 3D printable materials and 3D printing technologies used for the fabrication of permanent restorations, focusing on material properties that are clinically relevant. A literature search was performed on four databases (MEDLINE/PubMed, Scopus, Cochrane Library, Web of Science) for articles published from January 2013 until November 2023, using a combination of free words: (restorative dentistry OR prosthetic dentistry) AND (3D printing OR additive manufacturing OR rapid prototyping) AND materials. Two reviewers screened titles and/or abstracts of 2.468 unique studies. In total, 83 studies were selected for full-text reading, from which 36 were included in the review. The assessed variables were mechanical properties, reporting in most of the cases positive results, dimensional accuracy and fit, reporting conflicting results with a predominance of positive, aesthetic properties, with positive reports but scarcely addressed, and biological properties, almost unexplored in independent studies. Despite numerous studies with positive results in favor, papers with negative outcomes were also retrieved. Aesthetic and biological properties are conversely still mostly unexplored. There remains a lack of conclusive evidence for viable 3D printable restorative and prosthodontic materials for permanent restorations. Research should be strengthened by defining international standards for laboratory testing and, where pre-clinical data are promising, conducting clinical trials.

2.
Materials (Basel) ; 16(19)2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37834578

RESUMO

Amid chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) has been steadily increasing. This review aims to report on the translucency of these materials and the variables used to measure it. An electronic search was performed within the PubMed database within the period between 2 June 2011 and 11 September 2022. English-language papers investigating the translucency of IPS e.max CAD, Celtra Duo, Suprinity PC, Initial LiSi Block, Amber Mill, N!ce, and CEREC Tessera LSGC CAD/blocks were included in the search strategy. After an initial retrieval of 160 papers, the application of exclusion criteria, and the screening of abstracts and then of full texts, 33 papers were included in the study. The retrieved materials, with different degrees of translucency (LT, HT), were IPS e.max CAD (n = 33), Suprinity PC (n = 8), and Celtra Duo (n = 1). Concerning the examined colors, the most used was A2 (n = 20), followed by A1 (n = 8) and A3 (n = 2). The translucency parameter (TP) was the most used method (n = 30) with respect to the contrast ratio (CR) (n = 11) to assess translucency. Five papers measured both. Several specimens' thicknesses (0.5-4 mm) were investigated, with 1 mm (n = 23) being the most frequently analyzed. While a general tendency could be identified, conflicting results among different papers were reported.

3.
Materials (Basel) ; 16(12)2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37374581

RESUMO

Amongst chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) for indirect restorations has recently been increasing. Flexural strength is one of the most important parameters to consider in the clinical selection of materials. The aim of this paper is to review the flexural strength of LSGC and the methods used to measure it. METHODS: The electronic search was completed within PubMed database from 2 June 2011 to 2 June 2022. English-language papers investigating the flexural strength of IPS e.max CAD, Celtra Duo, Suprinity PC, and n!ce CAD/CAM blocks were included in the search strategy. RESULTS: From 211 potential articles, a total of 26 were identified for a comprehensive analysis. Categorization per material was carried out as follows: IPS e.max CAD (n = 27), Suprinity PC (n = 8), Celtra Duo (n = 6), and n!ce (n = 1). The three-point bending test (3-PBT) was used in 18 articles, followed by biaxial flexural test (BFT) in 10 articles, with one of these using the four-point bending test (4-PBT) as well. The most common specimen dimension was 14 × 4 × 1.2 mm (plates) for the 3-PBT and 12 × 1.2 mm (discs) for BFT. The flexural strength values for LSGC materials varied widely between the studies. SIGNIFICANCE: As new LSGC materials are launched on the market, clinicians need to be aware of their flexural strength differences, which could influence the clinical performance of restorations.

4.
Polymers (Basel) ; 15(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36987234

RESUMO

The aim of the study was to compare the translucency of CAD/CAM and printable composite materials for fixed dental prostheses (FDP). Eight A3 composite materials (7 CAD/CAM and 1 printable) for FPD were used to prepare a total of 150 specimens. CAD/CAM materials, all characterized by two different opacity levels, were: Tetric CAD (TEC) HT/MT; Shofu Block HC (SB) HT/LT; Cerasmart (CS) HT/LT; Brilliant Crios (BC) HT/LT; Grandio Bloc (GB) HT/LT; Lava Ultimate (LU) HT/LT, Katana Avencia (KAT) LT/OP. The printable system was Permanent Crown Resin. 1.0 mm-thick specimens were cut from commercial CAD/CAM blocks using a water-cooled diamond saw, or 3D printed. Measurements were performed using a benchtop spectrophotometer with an integrating sphere. Contrast Ratio (CR), Translucency Parameter (TP), and Translucency Parameter 00 (TP00) were calculated. One Way ANOVA followed by Tukey test for post hoc were performed for each of the translucency system. The tested materials exhibited a wide range of translucency values. CR ranged from 59 to 84, TP from 15.75 to 8.96, TP00 from 12.47 to 6.31. KAT(OP) and CS(HT) showed, respectively, the lowest and highest translucency for CR, TP and TP00. Due to the significant range of reported translucency values, clinicians should exercise caution when choosing the most appropriate material, especially considering factors such as substrate masking, and the necessary clinical thickness.

5.
Materials (Basel) ; 16(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36984045

RESUMO

The review aimed at analyzing the evidence available on 3D printable materials and techniques used for the fabrication of orthodontic appliances, focusing on materials properties that are clinically relevant. MEDLINE/PubMed, Scopus, and Cochrane Library databases were searched. Starting from an initial retrieval of 669 citations, 47 articles were finally included in the qualitative review. Several articles presented proof-of-concept clinical cases describing the digital workflow to manufacture a variety of appliances. Clinical studies other than these case reports are not available. The fabrication of aligners is the most investigated application of 3D printing in orthodontics, and, among materials, Dental LT Clear Resin (Formlabs) has been tested in several studies, although Tera Harz TC-85 (Graphy) is currently the only material specifically marketed for direct printing of aligners. Tests of the mechanical properties of aligners materials lacked homogeneity in the protocols, while biocompatibility tests failed to assess the influence of intraoral conditions on eluents release. The aesthetic properties of 3D-printed appliances are largely unexplored. The evidence on 3D-printed metallic appliances is also limited. The scientific evidence on 3D printable orthodontic materials and techniques should be strengthened by defining international standards for laboratory testing and by starting the necessary clinical trials.

6.
Materials (Basel) ; 16(6)2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36984216

RESUMO

BACKGROUND: To evaluate the effect of different experimental staining procedures on color stability and translucency of a nano-hybrid resin-based composite (RBC). METHODS: Forty-eight cylindrical-shaped specimens (10 × 2 mm) were prepared with a nano-hybrid RBC (Clearfil Majesty ES-2) and randomly divided in four groups according to the experimental staining procedure: G1) static immersion in a staining solution (coffee) (44 ± 1 °C); G2) staining cycling between coffee (44 ± 1°C) and distilled water (37 ± 1°C) with an experimental staining machine based on Arduino, an Open Source hardware development platform; G3) staining cycles as in G2 + brushing with a low abrasive toothpaste (Relative Dentin Abrasion RDA = 30) (Elmex Sensitive Professional); G4) staining cycles as in G3, with brushing performed with a very strong abrasive toothpaste (RDA = 90) (Lacult Active). Color parameters were recorded at the baseline (T0) after staining procedures (T1) and repolishing (T2) using a spectrophotometer. Color change (∆E00) and translucency (TP, CR) were evaluated. Data were statistically analyzed (p < 0.05). RESULTS: For ∆E00 after staining, Group 1 showed the highest color change and Group 3 the lowest. All groups were significantly different (p < 0.001) except for Group 2 vs. Group 4; after repolishing, Group 1 was significantly higher than Group 3 (p < 0.001), Group 2 (p < 0.001), and Group 4 (p = 0.003); Group 2 was higher than Group 3 (p < 0.001). For TP variable, after staining procedures, Group 2 was significantly higher than all other groups (p < 0.001), and Group 1 was significantly higher than Group 3 (p < 0.001) and Group 4 (p = 0.007). After repolishing, Group 4 was significantly lower than Group 3 (p = 0.008) and Group 2 (p = 0.027). Repolishing procedure significantly reduced color parameters. CONCLUSIONS: The investigated staining procedure induced significant differences in color stability and translucency. The use of a very strong abrasive toothpaste (RDA = 90) induced higher color change than a low abrasive one (RDA = 30). Repolishing procedures are able to partially reduce color change induced by artificial staining procedures.

7.
Polymers (Basel) ; 15(3)2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36771956

RESUMO

The color stability of resin cements plays a key role in the achievement of esthetically-pleasant restorations. Resin luting materials can be mainly divided into two main classes: adhesive (relying on previous application of adhesive systems) or self-adhesive (also known as one-step cements). The different chemical compositions determine their physio-mechanical characteristics which, in turns, influence their color stability. To evaluate the color variations of different dual-cured resin cements after water aging, 80 disc-shaped specimens (15 mm in diameter and 1.2 mm thick) were obtained from the following resin cements (n = 10): (1) Maxcem Elite Universal, MCU (Kerr); (2) RelyX Universal, RXU (3M); (3) Calibra Ceram, CAL (Dentsply); (4) Multilink, MUL (Ivoclar-Vivadent); (5) Panavia V5, PAN (Kuraray); (6) Calibra Universal, CUN (Dentsply); (7) SpeedCEM Plus, SCP (Ivoclar); and (8) Panavia SA, PSA (Kuraray). After light-polymerization, the specimens were measured with a spectrophotometer and CIELab* values were recorded. The specimens were then placed in a digitally controlled thermostatic water bath at 60° for 30 days and afterwards the color measurements were repeated. Color differences were calculated for each specimen before and after water-aging procedures with ΔEab formula and the data were statistically analyzed (p < 0.05). The type of cement statistically influenced the ΔEab (p < 0.05), with MCU showing the lowest color variations (4.3 ± 0.7) whereas RXU and PSA the highest (16.9 ± 1.6 and 16.8 ± 1.2, respectively). No differences were observed between CAL, CUN and SCP (p = 0.05). Color stability is related to the chemical composition of the resinous luting materials, thus material dependent.

8.
Polymers (Basel) ; 15(2)2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36679343

RESUMO

BACKGROUND: This systematic review aims to evaluate the color stability of resin composite CAD/CAM blocks (CCB) when submitted to staining solutions. METHODS: A systematic search was performed on different databases (Embase, Medline, Scopus, Web of Science). Search terms were: 'polymer infiltrated', 'polymer-based', 'resin nanoceramic', 'resin ceramic', 'hybrid composite', 'hybrid ceramic', 'composite ceramic', 'resin infiltrated', 'CAD-CAM', 'CAD/CAM', 'color stability', 'staining', 'staining susceptibility', 'color change', 'color difference'. INCLUSION CRITERIA: in vitro articles published in the English language until 18 September 2022 without initial time restriction evaluating the color stability of CCB when submitted to staining solutions. EXCLUSION CRITERIA: studies investigating color change induced by smoke or whitening treatments; studies not including a clinical evaluation of the results using the thresholds for color perceptibility and acceptability. Risk of bias assessment using the QUIN tool. FINDINGS: Out of the 378 initially retrieved articles, 19 were included in this review. They investigated 17 different CCBs and different artificial staining by liquid protocols, including coffee, red wine, tea, and cola. CCBs exceeded clinical acceptability thresholds for color shift in 18 out of 19 studies, with a significantly higher color stability than conventional hybrid resin-based composites (RBCs), and a significantly lower color stability than ceramic materials. The identified differences in CCBs in color stability can be attributed to the material's composition, but also to the heterogeneity of staining procedures. Interpretation and clinical implication: Clinicians should be aware that, although to a lower degree when compared to RBCs used in direct or indirect procedures, CCBs undergo color changes to a higher degree in comparison to ceramic materials.

9.
Materials (Basel) ; 16(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36614796

RESUMO

Despite the advent of metal-free solutions, porcelain-fused-to-metal restorations (PFM) are still widely used. Particularly for the latest ceramic systems, scarce information is present in the scientific literature about the ideal opaque layer thickness and the alloy color impact to achieve the desired final color of PFM restorations. This study aimed to evaluate the influence of opaque thickness variation layered on different metal alloys on the final color of PFM restorations. Opaque porcelain of one metal−ceramic system (VITA VM13) was layered in four different thicknesses (0.10 mm, 0.15 mm, 0.20 mm, and 0.25 mm) on three differently colored dental alloys: a gold−platinum alloy (yellowish), a gold−palladium alloy (light grayish), and a nickel−chromium alloy (dark grayish). The veneering porcelain layered over the opaque was kept constant (Base Dentine 0.45 mm, Transpa Dentine 0.50 mm, and Enamel 0.20 mm). Sixty specimens were fabricated, five samples for each combination of alloy/opaque thickness. The color difference (ΔE) between specimen and reference was measured using a clinical spectrophotometer. The two-way ANOVA revealed that the thickness of both the opaque (p < 0.001) and the metal alloy (p < 0.001) significantly influenced the ΔE values. Gray-colored alloys covered by a 0.10 mm thick opaque layer enabled the closest color match, whereas this occurred for yellow-color alloys covered by a 0.15 mm thick opaque layer. In contrast, the samples covered by a 0.25 mm thick opaque layer obtained the worst ΔE.

10.
J Esthet Restor Dent ; 35(2): 309-321, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36602255

RESUMO

OBJECTIVE: To conduct a systematic review on color stability of dental resin-based composites (RBC) exposed to conventional and electronic cigarettes. MATERIALS AND METHODS: In vitro studies reporting on the color stability of RBC exposed to conventional cigarettes or to e-cigarettes: both Tobacco Heating Systems (THS) and Electronic Nicotine Delivery Systems (ENDS). The quality of the included studies was assessed with the QUIN tool (risk-of-bias tool for assessing in vitro studies conducted in dentistry). A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was performed on four (n = 4) databases (Embase, Medline, Scopus, Web of Science) for articles published until March 28th, 2022. RESULTS: Of the 365 screened articles, 13 were included in this review. All the included articles analyzed conventional cigarette smoke (CS), four analyzed Electronic Nicotine Delivery Systems (ENDS) and two Tobacco Heating Systems (THS). In terms of study design, smoke exposure time, smoke flow, type and number of cigarettes a high variability was reported. CONCLUSIONS: The available evidence suggests that CS smoke significantly affects color stability. Electronic cigarettes show less color change that seems to be easily recovered under clinical acceptability thresholds, although evidence is scarce. CLINICAL SIGNIFICANCE: Clinicians should be aware, and should therefore warn their patients, that RBCs are subjected to irreversible color change if exposed to smoke. Electronic cigarettes (both ENDS and THS) induce less color change that can be recovered with repolishing or whitening procedures.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Materiais Dentários , Nicotiana , Fumar
11.
Materials (Basel) ; 15(21)2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36363425

RESUMO

Flexural strength (FS) and translucency (Contrast Ratio-CR) of three different factory crystallized silica-based glass ceramics, Celtra Duo (CD), N!ce (NI) and Li-Si Block, a lithium disilicate, IPS e.max CAD (LD), and a leucite-reinforced feldspathic ceramic, Empress CAD (EM), in two different translucencies (HT and LT) for use in chairside dental restorations have been compared. CAD blocks of the materials were cut into beams and tiles and processed following manufacturers' instructions. The beams were tested (3-PBT) to determine flexural strength, Weibull characteristic strength, and Weibull modulus; and tiles were tested to determine CR. All data were statistically analyzed. In addition, SEM analysis of the materials was performed. Differences in flexural strength (FS) and translucency (CR) between the materials were found to be statistically significant. FS decreased as follows (MPa): LDHT 350.88 ± 19.77 (a) = LDLT 343.57 ± 18.48 (a) > LSLT 202.15 ± 17.41 (b) = LSHT 196.93 ± 8.87 > NIHT 186.69 ± 13.06 (c) = CDLT 184.73 ± 13.63 (c) = CDHT 174.15 ± 21.76 (c) = NILT 172.12 ± 11.98 (c) > EMHT 131.16 ± 13.33 (e) = EMLT 127.65 ± 11.09. CR decreased as follows (mean ± sd): CDLT 74.1 ± 1.1 (a); LSLT 74.0 ± 1.1 (ab); NILT 73.3 ± 0.8 (ab); EMLT 73.0 ± 1.5 (ab); NIHT 72.4 ± 1.0 (bc); LDLT 71.3 ± 1.1 (bc); LTHT 65.2 ± 0.9 (de); LSHT 63.8 ± 1.1 (def); EMHT 636 ± 1.2 (ef); CDHT 62.2 ± 0.8 (f). Our findings show that factory-crystallized lithium silicate glass ceramics fulfill ISO standards for Classes 1 and 2. Therefore, they can be considered viable alternatives to produce single-unit restorations with a chairside procedure not requiring thermal treatment.

12.
Dent Mater J ; 41(6): 791-799, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36070929

RESUMO

The objective of this study was to review the experimental in vitro procedures employed to assess the color stability of resin-based composites exposed to smoke. A literature search was performed on four databases (Pubmed, Scopus, Embase, and Web of Science). The quality of the included papers was assessed with the Cochrane risk-of-bias tool (RoB 2). In total, 25 studies were selected for full-text reading, from which 12 were included in the review. The assessed variables were: dimensions, shape, time before exposure, finishing, smoke-type, exposure time, brushing simulation, color, measuring system, repolishing. A disk-shaped specimen was used in most studies (n=10) with a 2 mm thickness (n=7) in custom made devices equipped with vacuum pumps or in Vitrocell systems. Spectrophotometers were the most used devices (n=11). Color differences were quantified with ΔE (n=12), ΔE00 (n=1). The large variety of staining procedures suggests the need for standardization.


Assuntos
Resinas Compostas , Materiais Dentários , Cor , Propriedades de Superfície , Fumar , Teste de Materiais
13.
Materials (Basel) ; 15(11)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35683044

RESUMO

In order to improve fit and comfort, a maxillary protraction facemask customized to the patient's anatomy was produced by means of 3D face scanning, digital design and additive manufacturing. An 8-year-old patient in need of early treatment for the Class III malocclusion received a rapid palatal expander and a Petit-type facemask, whose components were digitally designed on a 3D scan of the patient's face. For face scanning, the iPad Pro 2018 tablet (Apple, Cupertino, CA, USA) with the Bellus3D DentalPro application (Bellus3D, Campbell, CA, USA) was used. Facemask components were modelled with 3D Blender software. The rests were 3D printed in BioMed Clear biocompatible resin (Formlabs, Somerville, MA, USA), and the bar in stainless steel. For greater comfort, the internal surface of the rests was lined with a polymer gel pad (Silipos, Niagara Falls, NY, USA). The manufacturing procedure of the customized facemask is patented. The patient wore the facemask at night for a period of 9 months. The patient's experience was evaluated with a questionnaire at 1 week, 3, 6, and 10 months of treatment. The customized facemask was well accepted by the patient and obtained the expected treatment outcome. Furthermore, 3D face scanning, 3D modelling and 3D printing allow for the manufacturing of customized facemasks with improved fit and comfort, favoring patient compliance and treatment success.

14.
Polymers (Basel) ; 14(9)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35566944

RESUMO

The aim of this in vitro study was to evaluate the effects of substrate and cement shades on the translucency and color of lithium-disilicate and zirconia CAD/CAM materials. Two light-cured resin cements (RelyX Veneer Cement; 3M; Choice 2 Veneer Cement; Bisco Dental) with a standardized thickness (0.1 mm) were tested in combination with two different monolithic CAD/CAM materials (E-Max CAD (LI2SI2O5); Ivoclar Vivadent; Katana (ZrO2); Kuraray-Noritake Dental) on two different colored composite substrates used as a dentin (Filtek Supreme XTE; 3M); for a total of 12 combinations (n = 10). The specimens' color was measured with a spectrophotometer (Spectroshade; MHT). Measurements were taken using the CIELAB color coordinate system (L*a*b*) against black and white backgrounds. L*a*b* values were statistically analyzed for the variables Substrate, Ceramic, and Cement by applying a Three-Way ANOVA followed by the Tukey Test for post-hoc comparison (p < 0.05). Translucency Parameter (TP) and Constant Ratio (CR) were assessed to evaluate translucency; acceptability and perceptibility thresholds (ΔE00 1.8 and 0.8) were used. Statistically significant influence was found for factors ceramic material, cement shade, and substrate color (p < 0.05). Unacceptable color differences were reported for Li2Si2O5. Opacity was significantly higher when white opaque cement shade was employed. Ceramic type and cement shade significantly influenced L*a*b* color coordinates. The final translucency and color of ceramic restorations can, therefore, be influenced by ceramic material, cement shade, and substrate color.

15.
J Esthet Restor Dent ; 34(6): 865-887, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35396818

RESUMO

OBJECTIVE: The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW: A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS: The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE: Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.


Assuntos
Materiais Dentários , Cor , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
16.
Materials (Basel) ; 15(3)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35161189

RESUMO

The need for bracket bonding to ceramic restorations is increasing. The aim of this study was to evaluate the effect of universal adhesives on bracket adhesion to polished or glazed lithium disilicate (LDS) and monolithic zirconia (MZ) surfaces. One hundred and twenty brackets (N = 10) were bonded to either polished or glazed LDS (e.max CAD B32, Ivoclar Vivadent, Schaan, Liechtenstein) and MZ (In-Ceram® YZ, VITA, Bad Sackingen, Germany) blocks using three different adhesives combined with Transbond™ XT Paste (3M Unitek, Monrovia, CA, USA). Tested universal adhesives were Scotchbond™ Universal Adhesive (SU, 3M St. Paul, MN, USA) and Assure Plus (AP, Reliance, Itasca, IL, USA). Transbond™ XT Primer (XTP, 3M Unitek, Monrovia, CA, USA) served as a control adhesive. Bracket bond strength was measured in shear mode (SBS). Failure type was determined by the Modified Adhesive Remnant Index (ARI). Data were statistically analyzed. On polished LDS, SU yielded bracket SBS significantly superior to those of AP and XTP. On polished MZ, the use of SU and AP significantly enhanced bracket retention as compared with XTP. Low SBS values, below the threshold of clinical acceptability, were reached by all tested adhesives on glazed LDS and MZ specimens. SBS measurements corresponded with failure type observations. Universal adhesives SU and AP could be considered for use on polished LDS and MZ surfaces.

17.
J Esthet Restor Dent ; 34(2): 423-429, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32282998

RESUMO

OBJECTIVE: To investigate the influence of opacity and color of luting cements on the final shade of metal-free restorations. MATERIALS AND METHODS: Five resin cement colors in combination with four different thicknesses of CAD/CAM ceramic materials were tested, and a composite substrate was used as dentin color reference (n = 3). Specimen color was measured with a spectrophotometer equipped with an integrating sphere before and after cementation (CIELAB). Cement and ceramic color and opacity (TP) were assessed by measuring the tested ceramic thickness as a 1-mm thick disk for each of the cement shades. The differences in color were evaluated (ΔE00 ). Data were statistically analyzed by a Two-Way ANOVA followed by the Tukey Test for post-hoc comparison (P < .05) and multiple comparison Pearson's test (P < .05); the acceptability and perceptibility threshold were evaluated. RESULTS: Statistically significant influence was found for factors ceramic thickness and cement shade (P < .001). Perceptible and unacceptable color changes were induced on the final restoration by resin cements (ranging from ΔE00  = 0.69 ± 0.54 to ΔE00  = 5.53 ± 0.46), the correlation between factors became strong (r2 > 0.6) in case of mismatch between color and translucency of cement and ceramic. Only the clear shade in combination with the thickest ceramic, resulted in an imperceptible color change (ΔE00  = 0.69 ± 0.54). CONCLUSIONS: The final shade of ceramic restorations can be influenced by resin cements; the magnitude of influence is related to the cement optical properties. CLINICAL SIGNIFICANCE: In order to influence the final shade of a ceramic restoration, a cement more opaque than the restorative material should be used. Conversely, in the case of a fitting shade of the restoration, a cement more translucent than the restoration should be used to avoid undesired changes.


Assuntos
Porcelana Dentária , Ligas Metalo-Cerâmicas , Cerâmica , Cor , Materiais Dentários , Porcelana Dentária/química , Teste de Materiais , Ligas Metalo-Cerâmicas/química , Cimentos de Resina/química , Propriedades de Superfície
18.
J Clin Med ; 12(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36615013

RESUMO

Nasopharyngeal swab sample collection is the first-line testing method for diagnosing COVID-19 infection and other respiratory infections. Current information on how to properly perform nasopharyngeal swabbing in children is largely defective. This study aimed at collecting nostril to nasopharynx distance measurements on lateral skull radiographs of children and adolescents to design a nasopharyngeal swab meant to standardize and facilitate the sample collection procedure. A total of 323 cephalograms of 152 male and 171 female children aged 4-14 years taken for orthodontic reasons were selected. On each cephalogram, the shortest distance between the most anterosuperior point of the nostril contour and the nasopharynx outline was measured in mm parallel to the palatal plane. Descriptive statistics of the measurements were calculated for each age group. The lower limit of the 95% confidence intervals of the measurements was taken as a reference to design a swab shaft with marks that, at each age, delimitate a safety boundary for swab progression up to the posterior nasopharyngeal wall. The simplification of the procedure enabled by the newly designed nasopharyngeal swab is valuable to help healthcare providers perform specimen collection on children in a safe and effective way, perhaps under the less-than-ideal conditions possibly occurring in 'point-of-need' contexts.

19.
Materials (Basel) ; 14(22)2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34832176

RESUMO

This study aimed at evaluating the effects of different surface conditionings on the microshear bond strength (µSBS) of a self-adhesive resin cement to VITA Suprinity (ZLS) and IPS e.max CAD (LD). Three surface conditioning protocols were performed on ZLS and LD before luting with a self-adhesive resin cement (RelyX Unicem 2, RXU): hydrofluoric acid (HF), HF + silane (HF + S), or Monobond Etch & Prime (EP). In each group, 15 cylindrical buildups of RXU were prepared on five milled bars and submitted to a µSBS test. Data were statistically analyzed with two-way ANOVA and Tukey's post hoc test (p < 0.05). Failure modes were recorded and classified as adhesive, mixed, cohesive in resin, or ceramic, and statistically analyzed with Fisher's exact test (p = 0.05). One additional bar per group was used for the morphological characterization of the conditioned surface by means of SEM. The material per se did not significantly influence adhesion (p = 0.744). Conditioning protocol was a significant factor: EP yielded significantly higher µSBS than HF (p = 0.005), while no significant differences emerged between EP and HF + S (p = 0.107), or HF + S and HF (p = 0.387). The material-conditioning protocol interaction was not statistically significant (p = 0.109). Significant intergroup differences were found in distribution of failure modes: mixed failures were predominant in the ZLS/EP group, while the other groups showed a prevalence of adhesive failures. The self-etching primer showed promising results in terms of immediate bond strength of a self-adhesive resin cement to lithium-silica-based glass ceramics, suggesting its alternative use to hydrofluoric acid and silane conditioning protocols.

20.
Polymers (Basel) ; 13(17)2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34502955

RESUMO

The aim of this in vitro study is to evaluate the effect of different acidic media on volumetric wear and surface roughness of CAD/CAM monolithic materials. Forty-eight rectangular specimens were prepared using different CAD/CAM monolithic materials: nanohybrid composite (Grandio Blocks, Voco), resin-based composite (Cerasmart, GC), lithium disilicate (E-Max, Ivoclar), and high-translucency zirconia (Katana STML, Kuraray Noritake). After storage in distilled water at 37 °C for two days, the specimens were tested using a chewing machine with a stainless-steel ball as an antagonist (49N loads, 250,000 cycles). Testing was performed using distilled water, Coca-Cola, and Red Bull as abrasive media. Wear and surface roughness analyses of the CAD/CAM materials were performed using a 3D profilometer and analyzed with two-way analysis of variance and post hoc pairwise comparison procedures. Worn surfaces were examined using scanning electron microscopy. Resin-based materials suffered higher volumetric wear than ceramics (p = 0.00001). Water induced significantly less volumetric wear than the other tested solutions (p = 0.0014), independent of the material tested. High-translucency zirconia showed less surface roughness than all the other materials tested. The selection of monolithic CAD/CAM materials to restore worn dentition due to erosive processes could impact restorative therapy stability over time. Resin-based materials seem to be more influenced by the acidic environment when subjected to a two-body wear test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...